{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,25]],"date-time":"2026-01-25T14:04:20Z","timestamp":1769349860563,"version":"3.49.0"},"reference-count":11,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2001,5,23]],"date-time":"2001-05-23T00:00:00Z","timestamp":990576000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance in Med"],"published-print":{"date-parts":[[2001,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>A novel fat saturation scheme is proposed which combines spectral fat saturation with a steady\u2010state 3D true Fast Imaging with Steady Precesson (TrueFISP) sequence. Fat saturation consisted of a conventional frequency\u2010selective excitation pulse surrounded by spoiler gradients. This saturation block was periodically repeated within a continuously running TrueFISP sequence. Except for the fat signals, the steady\u2010state signal formation and the resulting image contrast of TrueFISP was not modified by the periodically inserted fat saturation block. This was achieved by a \u03b1\/2 flip\u2010back pulse before the fat saturation block, which stores the established steady\u2010state transverse magnetization as pure longitudinal magnetization. After fat saturation this longitudinal magnetization was excited by a \u03b1\/2 preparation pulse to continue the TrueFISP acquisition. The resulting images show contrast identical to conventional TrueFISP images, but without the usually very bright fat signals. The short repetition time allows acquisition of a 3D data set of the abdomen within a single breath\u2010hold. Magn Reson Med 45:1075\u20131080, 2001. \u00a9 2001 Wiley\u2010Liss, Inc.<\/jats:p>","DOI":"10.1002\/mrm.1142","type":"journal-article","created":{"date-parts":[[2002,8,25]],"date-time":"2002-08-25T22:10:13Z","timestamp":1030313413000},"page":"1075-1080","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":174,"title":["Magnetization preparation during the steady state: Fat\u2010saturated 3D TrueFISP"],"prefix":"10.1002","volume":"45","author":[{"given":"Klaus","family":"Scheffler","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oliver","family":"Heid","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J\u00fcrgen","family":"Hennig","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2001,5,23]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-198410000-00001"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.155.5.2120945"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-199803000-00004"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1099-0534(1999)11:5<291::AID-CMR2>3.0.CO;2-J"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910040103"},{"key":"e_1_2_7_7_2","first-page":"15","article-title":"FISP\u2014a new fast MRI sequence","volume":"54","author":"Oppelt A","year":"1986","journal-title":"Electromedica (Engl Ed)"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/0730-725X(88)90477-8"},{"key":"e_1_2_7_9_2","unstructured":"DeimlingM HeidO.Magnetization prepared true FISP imaging. In: Proceedings of the 2nd Annual Meeting of the Society of Magnetic Resonance San Francisco 1994. p495."},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/0022-2364(89)90083-8"},{"key":"e_1_2_7_11_2","first-page":"480","volume-title":"Magnetic resonance imaging","author":"Haacke M","year":"1999"},{"key":"e_1_2_7_12_2","unstructured":"HeidO.Noniterative localized in vivo shimming in <15 s. In: Proceedings of the 4th Annual Meeting of ISMRM New York 1996. p363."}],"container-title":["Magnetic Resonance in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmrm.1142","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.1142","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,9]],"date-time":"2023-10-09T21:14:49Z","timestamp":1696886089000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.1142"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,5,23]]},"references-count":11,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2001,6]]}},"alternative-id":["10.1002\/mrm.1142"],"URL":"https:\/\/doi.org\/10.1002\/mrm.1142","archive":["Portico"],"relation":{},"ISSN":["0740-3194","1522-2594"],"issn-type":[{"value":"0740-3194","type":"print"},{"value":"1522-2594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2001,5,23]]},"assertion":[{"value":"2000-09-15","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2000-12-22","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2001-05-23","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}