{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T20:52:54Z","timestamp":1792615974664,"version":"4.5.0"},"reference-count":30,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2011,12,2]],"date-time":"2011-12-02T00:00:00Z","timestamp":1322784000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance in Med"],"published-print":{"date-parts":[[2012,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Contrast optimization of a three\u2010dimensional (3D) Fluid\u2010attenuated inversion recovery (FLAIR) sequence is examined in the context of multiple sclerosis. In order to develop 3D FLAIR for enhanced detection of lesions, an iterative approach based on theoretical considerations was used. The 3D FLAIR sequence was systematically acquired with incremental parameter changes on a single subject with multiple sclerosis in a 3\u2010T MRI scanner. Region of interest analysis was performed on the images, and the best estimate of the optimal acquisition parameters was established. This process was iterated on subsequent patients with multiple sclerosis until only marginal gains in quality were obtained. Three\u2010dimensional FLAIR for enhanced detection produced increased lesion detection and identification in the supratentorial and infratentorial regions when compared with default GE 3D FLAIR and two\u2010dimensional FLAIR sequences. Lesion border delineation was enhanced as evidenced by better lesion and white matter contrast ratios, demonstrating that the approach is a viable method for improved lesion detection. Magn Reson Med, 2012. \u00a9 2011 Wiley Periodicals, Inc.<\/jats:p>","DOI":"10.1002\/mrm.23289","type":"journal-article","created":{"date-parts":[[2011,12,9]],"date-time":"2011-12-09T11:10:59Z","timestamp":1323429059000},"page":"874-881","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":26,"title":["3D FLAIRED: 3D fluid attenuated inversion recovery for enhanced detection of lesions in multiple sclerosis"],"prefix":"10.1002","volume":"68","author":[{"given":"Paul","family":"Polak","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher","family":"Magnano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Zivadinov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guy","family":"Poloni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2011,12,2]]},"reference":[{"key":"e_1_2_7_2_2","doi-asserted-by":"publisher","DOI":"10.1002\/ana.20703"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1474-4422(08)70137-6"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1002\/ana.1032"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0074-7742(07)79020-7"},{"key":"e_1_2_7_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00415-008-1009-1"},{"key":"e_1_2_7_7_2","first-page":"699","article-title":"Fast spin\u2010echo and fast fluid\u2010attenuated inversion\u2010recovery versus conventional spin\u2010echo sequences for MR quantification of multiple sclerosis lesions","volume":"18","author":"Bastianello S","year":"1997","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1007\/s004150050483"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1001\/archneur.58.5.742"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.71.848.9828796"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-005-0107-z"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-008-1009-7"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.216.3.r00au46891"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.10658"},{"key":"e_1_2_7_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20863"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1177\/135245859900500415"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1177\/1051228405283291"},{"key":"e_1_2_7_18_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20605"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2009.03.001"},{"key":"e_1_2_7_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-510X(00)00339-7"},{"key":"e_1_2_7_21_2","doi-asserted-by":"publisher","DOI":"10.1259\/0007-1285-67-804-1258"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910030214"},{"key":"e_1_2_7_23_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21122"},{"key":"e_1_2_7_24_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910050411"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1183"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2004.07.051"},{"key":"e_1_2_7_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2008.10.055"},{"key":"e_1_2_7_28_2","doi-asserted-by":"publisher","DOI":"10.1136\/jnnp.70.6.773"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910340612"},{"key":"e_1_2_7_30_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2361040450"},{"key":"e_1_2_7_31_2","first-page":"54","article-title":"Double inversion recovery brain imaging at 3T: diagnostic value in the detection of multiple sclerosis lesions","volume":"28","author":"Wattjes MP","year":"2007","journal-title":"AJNR Am J Neuroradiol"}],"container-title":["Magnetic Resonance in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmrm.23289","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.23289","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,16]],"date-time":"2023-10-16T14:19:05Z","timestamp":1697465945000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.23289"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,12,2]]},"references-count":30,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2012,9]]}},"alternative-id":["10.1002\/mrm.23289"],"URL":"https:\/\/doi.org\/10.1002\/mrm.23289","archive":["Portico"],"relation":{},"ISSN":["0740-3194","1522-2594"],"issn-type":[{"value":"0740-3194","type":"print"},{"value":"1522-2594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,12,2]]},"assertion":[{"value":"2011-04-22","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2011-10-14","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2011-12-02","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}