{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,25]],"date-time":"2026-10-25T02:38:21Z","timestamp":1792895901753,"version":"4.5.0"},"reference-count":43,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2018,1,3]],"date-time":"2018-01-03T00:00:00Z","timestamp":1514937600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/100006775","name":"GE Healthcare","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006775","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"NIH","doi-asserted-by":"publisher","award":["1R01 AR062581"],"award-info":[{"award-number":["1R01 AR062581"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"NIH","doi-asserted-by":"publisher","award":["1R01 AR068987"],"award-info":[{"award-number":["1R01 AR068987"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance in Med"],"published-print":{"date-parts":[[2018,8]]},"abstract":"<jats:sec><jats:title>Purpose<\/jats:title><jats:p>To develop an accurate T<jats:sub>1<\/jats:sub> measurement method for short T<jats:sub>2<\/jats:sub> tissues using a combination of a 3\u2010dimensional ultrashort echo time cones actual flip angle imaging technique and a variable repetition time technique (3D UTE\u2010Cones AFI\u2010VTR) on a clinical 3T scanner.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>First, the longitudinal magnetization mapping function of the excitation pulse was obtained with the 3D UTE\u2010Cones AFI method, which provided information about excitation efficiency and B<jats:sub>1<\/jats:sub> inhomogeneity. Then, the derived mapping function was substituted into the VTR fitting to generate accurate T<jats:sub>1<\/jats:sub> maps. Numerical simulation and phantom studies were carried out to compare the AFI\u2010VTR method with a B<jats:sub>1<\/jats:sub>\u2010uncorrected VTR method, a B<jats:sub>1<\/jats:sub>\u2010uncorrected variable flip angle (VFA) method, and a B<jats:sub>1<\/jats:sub>\u2010corrected VFA method. Finally, the 3D UTE\u2010Cones AFI\u2010VTR method was applied to bovine bone samples (<jats:italic>N<\/jats:italic>\u2009=\u20096) and healthy volunteers (<jats:italic>N<\/jats:italic>\u2009=\u20093) to quantify the T<jats:sub>1<\/jats:sub> of cortical bone.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Numerical simulation and phantom studies showed that the 3D UTE\u2010Cones AFI\u2010VTR technique provides more accurate measurement of the T<jats:sub>1<\/jats:sub> of short T<jats:sub>2<\/jats:sub> tissues than the B<jats:sub>1<\/jats:sub>\u2010uncorrected VTR and VFA methods or the B<jats:sub>1<\/jats:sub>\u2010corrected VFA method. The proposed 3D UTE\u2010Cones AFI\u2010VTR method showed a mean T<jats:sub>1<\/jats:sub> of 240\u2009\u00b1\u200925 ms for bovine cortical bone and 218\u2009\u00b1\u200910 ms for the tibial midshaft of human volunteers, respectively, at 3\u2009T.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The 3D UTE\u2010Cones AFI\u2010VTR method can provide accurate T<jats:sub>1<\/jats:sub> measurements of short T<jats:sub>2<\/jats:sub> tissues such as cortical bone. Magn Reson Med 80:598\u2013608, 2018. \u00a9 2018 International Society for Magnetic Resonance in Medicine.<\/jats:p><\/jats:sec>","DOI":"10.1002\/mrm.27066","type":"journal-article","created":{"date-parts":[[2018,1,3]],"date-time":"2018-01-03T12:27:35Z","timestamp":1514982455000},"page":"598-608","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":78,"title":["Accurate T<sub>1<\/sub> mapping of short T<sub>2<\/sub> tissues using a three\u2010dimensional ultrashort echo time cones actual flip angle imaging\u2010variable repetition time (3D UTE\u2010Cones AFI\u2010VTR) method"],"prefix":"10.1002","volume":"80","author":[{"given":"Ya\u2010Jun","family":"Ma","sequence":"first","affiliation":[{"name":"Department of Radiology University of California San Diego California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xing","family":"Lu","sequence":"additional","affiliation":[{"name":"Department of Radiology University of California San Diego California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Carl","sequence":"additional","affiliation":[{"name":"GE Healthcare San Diego California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanchun","family":"Zhu","sequence":"additional","affiliation":[{"name":"Department of Radiology University of California San Diego California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nikolaus M.","family":"Szeverenyi","sequence":"additional","affiliation":[{"name":"Department of Radiology University of California San Diego California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Graeme M.","family":"Bydder","sequence":"additional","affiliation":[{"name":"Department of Radiology University of California San Diego California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric Y.","family":"Chang","sequence":"additional","affiliation":[{"name":"Department of Radiology University of California San Diego California USA"},{"name":"Radiology Service VA San Diego Healthcare System San Diego California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiang","family":"Du","sequence":"additional","affiliation":[{"name":"Department of Radiology University of California San Diego California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2018,1,3]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/0730-725X(87)90021-X"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20314"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20791"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.2906"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26292"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1006\/jmra.1993.1133"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20896"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910350217"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21729"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21083"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.1403"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21368"},{"key":"e_1_2_7_14_1","unstructured":"ChavezS StaniszG.A simple and fast flip angle calibration method. In Proceedings of the 17th Annual Meeting of ISMRM Honolulu Hawaii USA 2009. p375."},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22357"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21120"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.21130"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22394"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24817"},{"key":"e_1_2_7_20_1","unstructured":"HanM LarsonPEZ KrugR RiekeV.Actual flip angle imaging to improve T1measurement for short T2tissues. In Proceedings of the 23rd Annual Meeting of ISMRM Toronto Canada 2015. p.501."},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22562"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2010.03.005"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1053\/crad.2003.1157"},{"key":"e_1_2_7_24_1","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-200311000-00001"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910400615"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2010.09.013"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22433"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26908"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20796"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25823"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.23199"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.10407"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20605"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25135"},{"key":"e_1_2_7_35_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2482071995"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.25692"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0103296"},{"key":"e_1_2_7_38_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26716"},{"key":"e_1_2_7_39_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.3709"},{"key":"e_1_2_7_40_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.1631"},{"key":"e_1_2_7_41_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2016160780"},{"key":"e_1_2_7_42_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25375"},{"key":"e_1_2_7_43_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21391"},{"key":"e_1_2_7_44_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26648"}],"container-title":["Magnetic Resonance in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmrm.27066","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.27066","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,24]],"date-time":"2023-09-24T15:08:47Z","timestamp":1695568127000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.27066"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1,3]]},"references-count":43,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018,8]]}},"alternative-id":["10.1002\/mrm.27066"],"URL":"https:\/\/doi.org\/10.1002\/mrm.27066","archive":["Portico"],"relation":{},"ISSN":["0740-3194","1522-2594"],"issn-type":[{"value":"0740-3194","type":"print"},{"value":"1522-2594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1,3]]},"assertion":[{"value":"2017-09-11","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2017-12-11","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-01-03","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}