{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T18:23:00Z","timestamp":1767896580087,"version":"3.49.0"},"reference-count":36,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2020,7,21]],"date-time":"2020-07-21T00:00:00Z","timestamp":1595289600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance in Med"],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:sec><jats:title>Purpose<\/jats:title><jats:p>Intracranial and intraspinal compliance are parameters of interest in the diagnosis and prediction of treatment outcome in patients with normal pressure hydrocephalus and other forms of communicating hydrocephalus. A noninvasive method to estimate the spinal cerebrospinal fluid (CSF) pulse wave velocity (PWV) as a measure of compliance was developed using a multiband cine phase\u2010contrast MRI sequence and a foot\u2010to\u2010foot algorithm.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>We used computational simulations to estimate the accuracy of the MRI acquisition and transit\u2010time algorithm. In vitro measurements were performed to investigate the reproducibility and accuracy of the measurements under controlled conditions. In vivo measurements in 20 healthy subjects and 2 patients with normal pressure hydrocephalus were acquired to show the technical feasibility in a clinical setting.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Simulations showed a mean deviation of the calculated CSF PWV of 3.41%\u00a0\u00b1\u00a02.68%. In vitro results were in line with theory, showing a square\u2010root relation between PWV and transmural pressure and a good reproducibility with SDs of repeated measurements below 5%. Mean CSF PWV over all healthy subjects was 5.83\u00a0\u00b1\u00a03.36\u00a0m\/s. The CSF PWV measurements in the patients with normal pressure hydrocephalus were distinctly higher before CSF shunt surgery (33.80\u00a0\u00b1\u00a06.75\u00a0m\/s and 31.31\u00a0\u00b1\u00a07.82\u00a0m\/s), with a decrease 5 days after CSF shunt surgery (15.69\u00a0\u00b1\u00a03.37\u00a0m\/s).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>This study evaluates the feasibility of CSF PWV measurements using a multiband cine phase\u2010contrast MRI sequence. In vitro and in vivo measurements showed that this method is a potential tool for the noninvasive estimation of intraspinal compliance.<\/jats:p><\/jats:sec>","DOI":"10.1002\/mrm.28430","type":"journal-article","created":{"date-parts":[[2020,7,21]],"date-time":"2020-07-21T18:48:14Z","timestamp":1595357294000},"page":"197-208","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Cerebrospinal fluid pulse wave velocity measurements: In vitro and in vivo evaluation of a novel multiband cine phase\u2010contrast MRI sequence"],"prefix":"10.1002","volume":"85","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3064-0247","authenticated-orcid":false,"given":"Kristina","family":"Sonnabend","sequence":"first","affiliation":[{"name":"Department of Diagnostic and Interventional Radiology University of Cologne, Faculty of Medicine and University Hospital Cologne Cologne Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gerrit","family":"Brinker","sequence":"additional","affiliation":[{"name":"Department of General Neurosurgery Center for Neurosurgery University of Cologne, Faculty of Medicine and University Hospital Cologne Cologne Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Maintz","sequence":"additional","affiliation":[{"name":"Department of Diagnostic and Interventional Radiology University of Cologne, Faculty of Medicine and University Hospital Cologne Cologne Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0986-0042","authenticated-orcid":false,"given":"Alexander C.","family":"Bunck","sequence":"additional","affiliation":[{"name":"Department of Diagnostic and Interventional Radiology University of Cologne, Faculty of Medicine and University Hospital Cologne Cologne Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4295-4585","authenticated-orcid":false,"given":"Kilian","family":"Weiss","sequence":"additional","affiliation":[{"name":"Department of Diagnostic and Interventional Radiology University of Cologne, Faculty of Medicine and University Hospital Cologne Cologne Germany"},{"name":"Philips GmbH Hamburg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2020,7,21]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12987-019-0129-6"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/3-211-32318-X_62"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.3171\/jns.2005.103.1.0046"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1590\/S0004-282X1997000200003"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1097\/00006123-200111000-00028"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1975.43.5.0523"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1983.59.5.0817"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.3171\/jns.1997.87.5.0687"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.217.3.r00dc42877"},{"key":"e_1_2_8_11_1","volume-title":"Die Pulscurve","author":"Isebree MA","year":"1878"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/andp.18782411206"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1098\/rspb.1922.0022"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/0141-5425(92)90060-X"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880050604"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.20227"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2008.2011647"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12987-019-0164-3"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.72.6.1257"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1186\/1532-429X-14-77"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1523\/JNEUROSCI.3246-14.2015"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-2586(200004)11:4<438::AID-JMRI12>3.0.CO;2-O"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2015.07.073"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.25591"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20401"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20787"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25897"},{"key":"e_1_2_8_28_1","volume-title":"ISMRM & SMRT Virtual Conference & Exhibition","author":"Sonnabend K","year":"2020"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12872-016-0292-5"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1136\/jcp.2007.047175"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-013-0854-y"},{"key":"e_1_2_8_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/0141-5425(79)90010-4"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.1115\/1.2073687"},{"key":"e_1_2_8_34_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12872-016-0224-4"},{"key":"e_1_2_8_35_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.20999"},{"key":"e_1_2_8_36_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12968-017-0341-y"},{"key":"e_1_2_8_37_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.27752"}],"container-title":["Magnetic Resonance in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmrm.28430","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.28430","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/mrm.28430","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.28430","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,2]],"date-time":"2023-09-02T11:13:12Z","timestamp":1693653192000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.28430"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,21]]},"references-count":36,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,1]]}},"alternative-id":["10.1002\/mrm.28430"],"URL":"https:\/\/doi.org\/10.1002\/mrm.28430","archive":["Portico"],"relation":{},"ISSN":["0740-3194","1522-2594"],"issn-type":[{"value":"0740-3194","type":"print"},{"value":"1522-2594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,21]]},"assertion":[{"value":"2020-02-17","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-06-23","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-07-21","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}