{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T06:37:05Z","timestamp":1784097425414,"version":"3.55.0"},"reference-count":47,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2024,9,2]],"date-time":"2024-09-02T00:00:00Z","timestamp":1725235200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/100006775","name":"GE Healthcare","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006775","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["NIH R01\u2010EB009055"],"award-info":[{"award-number":["NIH R01\u2010EB009055"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["NIH R01\u2010CA249893"],"award-info":[{"award-number":["NIH R01\u2010CA249893"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance in Med"],"published-print":{"date-parts":[[2025,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>To enable diffusion weighted imaging in prostate patients with metallic total hip replacements in clinically feasible scan times for prostate cancer screening, and avoid distortion and dropout artifacts present in the conventionally used Echo Planar Imaging (EPI).<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A reduced field of view (FOV) diffusion\u2010prepared sequence that is robust to the B inhomogeneities produced by total hip replacements was achieved using high radiofrequency (RF) bandwidth pulses and manipulation for stimulated echo pathways. The reduced FOV along the A\/P direction was obtained using slice\u2010select gradient reversal, and the prepared magnetization was imaged with a three\u2010dimensional RF\u2010spoiled gradient echo readout. The sequence was validated in phantom experiments, in vivo in healthy volunteers with and without total hip replacements, and in vivo in patients undergoing a standard MRI prostate exam.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The proposed sequence is robust to shading and distortion artifacts that are encountered by standard diffusion\u2010weighted EPI in the presence of moderate off\u2010resonance. Apparent diffusion coefficient estimates obtained by the proposed sequence were comparable to those obtained with diffusion\u2010weighted EPI.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Acquisition of distortionless diffusion weighted images of the prostate is feasible in patients with total hip replacements on conventional, whole\u2010body 3T MRI, using a <jats:italic>b<\/jats:italic>\u2010value of 800  and nominal resolution of 1.7  1.7  4 mm<jats:sup>3<\/jats:sup> in scan times of 6 min.<\/jats:p><\/jats:sec>","DOI":"10.1002\/mrm.30280","type":"journal-article","created":{"date-parts":[[2024,9,2]],"date-time":"2024-09-02T09:29:16Z","timestamp":1725269356000},"page":"261-275","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["A diffusion\u2010prepared reduced FOV sequence for prostate MRI near metallic implants"],"prefix":"10.1002","volume":"93","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7945-902X","authenticated-orcid":false,"given":"Philip K.","family":"Lee","sequence":"first","affiliation":[{"name":"Radiology Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeremiah J.","family":"Hess","sequence":"additional","affiliation":[{"name":"Radiology Stanford University  Stanford California USA"},{"name":"Bioengineering Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew A.","family":"Gomella","sequence":"additional","affiliation":[{"name":"Radiology Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas M.","family":"Loening","sequence":"additional","affiliation":[{"name":"Radiology Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian A.","family":"Hargreaves","sequence":"additional","affiliation":[{"name":"Radiology Stanford University  Stanford California USA"},{"name":"Bioengineering Stanford University  Stanford California USA"},{"name":"Electrical Engineering Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2024,9,2]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.3389\/fpubh.2022.811044"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00261-016-0871-z"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.eururo.2019.02.033"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000429"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.N.01141"},{"key":"e_1_2_8_7_1","article-title":"Projections and epidemiology of primary hip and knee arthroplasty in medicare patients to 2040\u20102060","volume":"8","author":"Shichman I","year":"2023","journal-title":"JB JS Open Access"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2013.01.038"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/S1053-8119(03)00336-7"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.1509"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.25708"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26737"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.29153"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.3733"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20863"},{"key":"e_1_2_8_16_1","volume-title":"33rd Annual Meeting of the ISMRM","author":"Hess JJ","year":"2024"},{"key":"e_1_2_8_17_1","volume-title":"33rd Annual Meeting of the ISMRM","author":"McElroy S","year":"2024"},{"key":"e_1_2_8_18_1","first-page":"43","article-title":"A k\u2010space analysis of small tip\u2010angle excitation","volume":"81","author":"John P","year":"1989","journal-title":"J Magn Reson"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.24619"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25897"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26313"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.597854"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/cmr.b.20034"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.22313"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1186\/s40824-018-0144-8"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.3390\/ma12030495"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.juro.2009.06.047"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1102\/1470-7330.2010.0004"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1109\/42.75611"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910320516"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.1716296"},{"key":"e_1_2_8_32_1","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1006\/jmra.1995.0750","article-title":"Stretched adiabatic pulses for broadband spin inversion","volume":"117","author":"Eriks K","year":"1995","journal-title":"J Magn Reson A"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24751"},{"key":"e_1_2_8_34_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24267"},{"key":"e_1_2_8_35_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.10531"},{"key":"e_1_2_8_36_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20706"},{"key":"e_1_2_8_37_1","first-page":"183","article-title":"A fast iterative shrinkage\u2010thresholding algorithm","volume":"2","author":"Amir B","year":"2009","journal-title":"Soc Ind Appl Math J Imaging Sci"},{"key":"e_1_2_8_38_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.25727"},{"key":"e_1_2_8_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2017.12.020"},{"key":"e_1_2_8_40_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(16)32401-1"},{"key":"e_1_2_8_41_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.27050"},{"key":"e_1_2_8_42_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.28061"},{"key":"e_1_2_8_43_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21640"},{"key":"e_1_2_8_44_1","doi-asserted-by":"publisher","DOI":"10.1067\/j.cpradiol.2017.03.004"},{"key":"e_1_2_8_45_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2022.08.008"},{"key":"e_1_2_8_46_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22418"},{"key":"e_1_2_8_47_1","doi-asserted-by":"publisher","DOI":"10.3389\/fendo.2020.00421"},{"key":"e_1_2_8_48_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00066-011-2201-2"}],"container-title":["Magnetic Resonance in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.30280","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,28]],"date-time":"2024-10-28T19:11:02Z","timestamp":1730142662000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.30280"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,2]]},"references-count":47,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,1]]}},"alternative-id":["10.1002\/mrm.30280"],"URL":"https:\/\/doi.org\/10.1002\/mrm.30280","archive":["Portico"],"relation":{},"ISSN":["0740-3194","1522-2594"],"issn-type":[{"value":"0740-3194","type":"print"},{"value":"1522-2594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,2]]},"assertion":[{"value":"2024-04-22","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-08-12","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-09-02","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}