{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T17:22:24Z","timestamp":1787505744427,"version":"build-2736575974"},"reference-count":31,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2025,2,4]],"date-time":"2025-02-04T00:00:00Z","timestamp":1738627200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["R01\u2010EB019241"],"award-info":[{"award-number":["R01\u2010EB019241"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["R01EB035109"],"award-info":[{"award-number":["R01EB035109"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["R01EB036127"],"award-info":[{"award-number":["R01EB036127"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100006775","name":"GE Healthcare","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006775","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance in Med"],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Conventional MRI coils offer suboptimal parallel imaging performance for young children. Our goal was to enhance imaging acceleration by dedicated, flexible high\u2010density coil design for pediatric patients at 3T.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We design, construct, and evaluate a highly flexible small loop array. Key design notes include full\u2010wave simulation and analysis of the dual\u2010turn loop, miniature feedboard allocation at the loop center, and cable management. Phantom experiments and adult and pediatric volunteer case studies were conducted to evaluate the small loop array imaging performance compared to commercial reference coils.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Dual\u2010turn loop configuration forms higher preamp decoupling impedance than the same size single\u2010turn, supporting a flexible form factor that requires a wide range of critical overlap. Both phantom and in\u2010vivo studies demonstrate superior parallel imaging performance or high spatial resolution imaging using the small loop, compared to commercial reference coils.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>A dedicated high\u2010density coil array with a minimum inter\u2010component interference layout design allows a flexible form factor and higher imaging accelerations. Phantom and in\u2010vivo volunteer case studies demonstrate promising results in improving efficiency for pediatric patients in routine clinical imaging procedures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/mrm.30456","type":"journal-article","created":{"date-parts":[[2025,2,4]],"date-time":"2025-02-04T04:54:57Z","timestamp":1738644897000},"page":"2655-2666","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["A 60\u2010channel high\u2010density flexible receive array for pediatric abdominal MRI"],"prefix":"10.1002","volume":"93","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4362-561X","authenticated-orcid":false,"given":"Wonje","family":"Lee","sequence":"first","affiliation":[{"name":"Department of Radiology Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunjeong","family":"Stickle","sequence":"additional","affiliation":[{"name":"GE HealthCare Coils  Aurora Ohio USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clyve","family":"Follante","sequence":"additional","affiliation":[{"name":"GE HealthCare Coils  Aurora Ohio USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Grafendorfer","sequence":"additional","affiliation":[{"name":"GE HealthCare Coils  Aurora Ohio USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taeyoung","family":"Yang","sequence":"additional","affiliation":[{"name":"GE HealthCare Coils  Aurora Ohio USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1625-9709","authenticated-orcid":false,"given":"Fraser","family":"Robb","sequence":"additional","affiliation":[{"name":"GE HealthCare Coils  Aurora Ohio USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Radiology Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5918-4172","authenticated-orcid":false,"given":"John","family":"Pauly","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Greig","family":"Scott","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shreyas","family":"Vasanawala","sequence":"additional","affiliation":[{"name":"Department of Radiology Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4009-6196","authenticated-orcid":false,"given":"Ali","family":"Syed","sequence":"additional","affiliation":[{"name":"Department of Radiology Stanford University  Stanford California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,2,4]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2008.06.034"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-011-2103-6"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00247-011-2147-7"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.1148\/rg.2020190112"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910160203"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S"},{"key":"e_1_2_9_8_1","volume-title":"Coil Array Design for Parallel Imaging: Theory and Applications","author":"Sodickson DK","year":"2011"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.1046"},{"key":"e_1_2_9_10_1","first-page":"75","article-title":"Massively parallel MRI detector arrays","volume":"2013","author":"Boris K","year":"1997","journal-title":"J Magn Reson"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.10171"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25655"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22028"},{"key":"e_1_2_9_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.28843"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25999"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.29147"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.21463"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26803"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20183"},{"key":"e_1_2_9_20_1","first-page":"394","volume-title":"Theory and Application of Array Coils in MR Spectroscopy","author":"Wright SM","year":"1997"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2019190209"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.27865"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1038\/ncomms10839"},{"key":"e_1_2_9_24_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2019181883"},{"key":"e_1_2_9_25_1","first-page":"753","article-title":"Tech Trends","volume":"50","author":"Stormont R","year":"2017","journal-title":"J Calif Dent Assoc"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24751"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20713"},{"key":"e_1_2_9_28_1","first-page":"1439","article-title":"Image reconstruction in SNR units: a general method for SNR measurement","volume":"2005","author":"Peter K","year":"2007","journal-title":"Magn Reson Med"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.25482"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20925"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21948"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24427"}],"container-title":["Magnetic Resonance in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.30456","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T11:22:33Z","timestamp":1762514553000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.30456"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,4]]},"references-count":31,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025,6]]}},"alternative-id":["10.1002\/mrm.30456"],"URL":"https:\/\/doi.org\/10.1002\/mrm.30456","archive":["Portico"],"relation":{},"ISSN":["0740-3194","1522-2594"],"issn-type":[{"value":"0740-3194","type":"print"},{"value":"1522-2594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,4]]},"assertion":[{"value":"2024-09-02","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-16","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-02-04","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}