{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,7]],"date-time":"2025-11-07T19:35:24Z","timestamp":1762544124530,"version":"3.41.2"},"reference-count":39,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2025,6,4]],"date-time":"2025-06-04T00:00:00Z","timestamp":1748995200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance in Med"],"published-print":{"date-parts":[[2025,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Purpose<\/jats:title><jats:p>Water suppression is a necessary component to standard MR spectroscopy experiments due to the approximately 5000\u201310\u2009000\u2010fold higher water concentration and signal intensity compared with that of the metabolites and macromolecules of interest. Here, a novel algorithm referred to as constrained optimized water suppression (COWS) was developed, which enables generation of effective water suppression modules with an arbitrary number of radiofrequency (RF) pulses, and flexibly accommodates minimum durations between pulses, minimum total module duration, and maximum flip angles.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>We use the COWS algorithm to create a water\u2010suppression module with seven pulses, the same number of RF pulses as typical VAPOR7, at a reduced module duration of 236\u2009ms, referred to as COWS(7;236), as well as one at the typical VAPOR duration but with an increased number of RF pulses, referred to as COWS(12;626). Experimentally, both COWS schemes were compared with variable power radio frequency pulses with optimized relaxation delays (VAPOR) using single\u2010voxel spectroscopy in the prefrontal cortex, the posterior frontal lobe, and the occipital lobe from data collected from 10 participants on a 3T Siemens MRI scanner.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>We found that both COWS(7;236) and COWS(12;626) perform similar to VAPOR7 for metabolites, whereas COWS(7;236) had improved performance than VAPOR for macromolecules at a reduced 236\u2010ms duration.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>COWS can be used to develop flexible study\u2010specific water suppression that can perform similarly for metabolite spectra or with improved performance for macromolecule spectra compared with VAPOR7, at a lower module duration.<\/jats:p><\/jats:sec>","DOI":"10.1002\/mrm.30550","type":"journal-article","created":{"date-parts":[[2025,6,4]],"date-time":"2025-06-04T23:48:57Z","timestamp":1749080937000},"page":"895-904","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Constrained optimized water suppression for <scp><sup>1<\/sup>H<\/scp> MR spectroscopy"],"prefix":"10.1002","volume":"94","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9909-9930","authenticated-orcid":false,"given":"Kay Chioma","family":"Igwe","sequence":"first","affiliation":[{"name":"Department of Biomedical Engineering Columbia University Fu Foundation School of Engineering and Applied Science   New York New York USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin","family":"Gajdo\u0161\u00edk","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering Columbia University Fu Foundation School of Engineering and Applied Science   New York New York USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1505-201X","authenticated-orcid":false,"given":"Christoph","family":"Juchem","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering Columbia University Fu Foundation School of Engineering and Applied Science   New York New York USA"},{"name":"Department of Radiology Columbia University College of Physicians and Surgeons  New York New York USA"},{"name":"High Field MR Center, Center for Medical Physics and Biomedical Engineering Medical University of Vienna  Vienna Austria"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5012-3007","authenticated-orcid":false,"given":"Karl","family":"Landheer","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering Columbia University Fu Foundation School of Engineering and Applied Science   New York New York USA"},{"name":"Regeneron Genetics Center  Tarrytown New York USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,6,4]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/30\/4\/008"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1006\/jmrb.1994.1048"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522\u20102594(199904)41:4<649::AID\u2010MRM2>3.0.CO;2\u2010G"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22708"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.27886"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2010.06.006"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.4324"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.27587"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.27133"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.1366"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.28282"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pnmrs.2014.12.001"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910140104"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20549"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26873"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.27742"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.4236"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.26846"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.4459"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.28076"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2016.10.043"},{"key":"e_1_2_7_23_1","first-page":"3266","volume-title":"Proceedings of the Annual Meeting of ISMRM","author":"Igwe K","year":"2024"},{"key":"e_1_2_7_24_1","first-page":"2211","volume-title":"Proceedings of the Annual Meeting of ISMRM, Vancouver","author":"Landheer K","year":"2021"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522\u20102586(199904)9:4<531::AID\u2010JMRI4>3.0.CO;2\u2010L"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20605"},{"key":"e_1_2_7_27_1","article-title":"Measurements of T1 relaxation times at 3.0T: implications for clinical MRA","author":"Lin C","year":"2001","journal-title":"Proceedings of the 9th Annual Meeting of ISMRM, Glasgow, Scotland"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1006\/jmre.2001.2340"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21302"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.27952"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22535"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.1006\/jmra.1995.1179"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.713"},{"key":"e_1_2_7_34_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598\u2010021\u201081193\u20109"},{"key":"e_1_2_7_35_1","unstructured":"JuchemC.INSPECTOR\u2014Magnetic Resonance Spectroscopy Software.http:\/\/innovation.columbia.edu\/technologies\/cu17130_INSPECTOR."},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910400508"},{"key":"e_1_2_7_37_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF03166960"},{"key":"e_1_2_7_38_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.29222"},{"key":"e_1_2_7_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ab.2016.10.019"},{"key":"e_1_2_7_40_1","unstructured":"LandheerK JuchemC.COWS: water suppression algorithm for magnetic resonance spectroscopy. Accessed April 07 2021.https:\/\/inventions.techventures.columbia.edu\/technologies\/cows\u2010water\u2010algorithm\u2010\u2010CU21111."}],"container-title":["Magnetic Resonance in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.30550","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,20]],"date-time":"2025-07-20T05:39:16Z","timestamp":1752989956000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.30550"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,4]]},"references-count":39,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["10.1002\/mrm.30550"],"URL":"https:\/\/doi.org\/10.1002\/mrm.30550","archive":["Portico"],"relation":{},"ISSN":["0740-3194","1522-2594"],"issn-type":[{"type":"print","value":"0740-3194"},{"type":"electronic","value":"1522-2594"}],"subject":[],"published":{"date-parts":[[2025,6,4]]},"assertion":[{"value":"2024-08-14","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-04-11","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-06-04","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}