{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,20]],"date-time":"2026-04-20T14:44:06Z","timestamp":1776696246895,"version":"3.51.2"},"reference-count":49,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2025,9,29]],"date-time":"2025-09-29T00:00:00Z","timestamp":1759104000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003343","name":"Cambridge Trust","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003343","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000265","name":"Medical Research Council","doi-asserted-by":"publisher","award":["MR\/M008983\/1"],"award-info":[{"award-number":["MR\/M008983\/1"]}],"id":[{"id":"10.13039\/501100000265","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000265","name":"Medical Research Council","doi-asserted-by":"publisher","award":["N013433\u20101"],"award-info":[{"award-number":["N013433\u20101"]}],"id":[{"id":"10.13039\/501100000265","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100018956","name":"NIHR Cambridge Biomedical Research Centre","doi-asserted-by":"publisher","award":["BRC\u20101215\u201020014"],"award-info":[{"award-number":["BRC\u20101215\u201020014"]}],"id":[{"id":"10.13039\/501100018956","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance in Med"],"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>\n                      Turbo spin echo (TSE) is important clinically. Unfortunately, 7\u2009T TSE suffers from B\n                      <jats:sub>1<\/jats:sub>\n                      <jats:sup>+<\/jats:sup>\n                      \u2010induced signal dropouts. Magnitude\u2010based parallel transmit (pTx) pulse design algorithms cannot enforce phase patterns complying with the Carr\u2010Purcell\u2010Meiboom\u2010Gill conditions (90\u00b0 phase shift between excitation and refocusing). We introduce scalable spokes pTx pulses for 7\u2009T TSE imaging.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Theory<\/jats:title>\n                    <jats:p>\n                      We define\n                      <jats:italic>scalable spokes pulses<\/jats:italic>\n                      as having time\u2010symmetric RF waveforms, antisymmetric in\u2010plane gradients, and rephased subpulse slice\u2010selection gradients. They produce flip angles that are approximately proportional to the applied voltage with voltage\u2010independent phase patterns.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Scalable spokes pulses were designed for a phantom. Scaling behavior was characterized via Bloch simulations. Performance in terms of TSE echo homogeneity was assessed by extended phase graph simulations using in vivo field maps.<\/jats:p>\n                    <jats:p>Performance was validated for TSE acquisitions in a phantom and in vivo. Hippocampal TSE imaging was performed for four subjects comparing circularly polarized (CP), RF shimming, and scalable spokes pulses.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Scalable spokes pTx pulses show similar scaling behavior to previously proposed 3D k\n                      <jats:sub>T<\/jats:sub>\n                      \u2010point pulses. Scalable three\u2010spoke pulses decrease flip\u2010angle RMS error across subjects compared to CP mode pulses (11% vs. 23% for 120\u00b0 pulses). TSE images with these pulses recover signals in cerebellum and temporal lobes.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Scalable spokes pTx pulses produce flip angles that vary approximately linearly with peak voltage while maintaining consistent spatial patterns of phase. Together with their spatial flip\u2010angle homogeneity, these pulses enable high\u2010fidelity 2D slice\u2010by\u2010slice TSE imaging at 7\u2009T, albeit with reduced slice coverage with our choice of homogeneity target under the current vendor\u2010provided specific absorption rate constraints on 7\u2009T MRI scanners.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/mrm.70068","type":"journal-article","created":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T06:32:18Z","timestamp":1759213938000},"page":"740-755","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Scalable spokes\n                    <scp>pTx<\/scp>\n                    pulses for\n                    <scp>2D<\/scp>\n                    turbo\u2010spin\u2010echo imaging at\n                    <scp>7\u2009T<\/scp>"],"prefix":"10.1002","volume":"95","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5401-6070","authenticated-orcid":false,"given":"Minghao","family":"Zhang","sequence":"first","affiliation":[{"name":"Wolfson Brain Imaging Centre, University of Cambridge   Cambridge United Kingdom"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1275-1197","authenticated-orcid":false,"given":"Christopher T.","family":"Rodgers","sequence":"additional","affiliation":[{"name":"Wolfson Brain Imaging Centre, University of Cambridge   Cambridge United Kingdom"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,9,29]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910030602"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2011.07.007"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1093\/brain\/awz144"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1528-1167.2012.03610.x"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.0000000000011413"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2016.11.031"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1156"},{"key":"e_1_2_10_9_1","doi-asserted-by":"crossref","unstructured":"KlodowskiK ZhangM JenJP et al.Parallel transmit improves 7T MRI adult epilepsy pre\u2010surgical evaluation. 2024 medRxiv. doi:10.1101\/2024.10.28.24316232","DOI":"10.1101\/2024.10.28.24316232"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2017.07.007"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000388"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRev.94.630"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.1716296"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880010614"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.216.3.r00au46891"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-008-1009-7"},{"key":"e_1_2_10_17_1","unstructured":"GrasV MauconduitF VignaudA et al.PASTeUR: Package of Anatomical Sequences using parallel Transmission UniveRsal kT\u2010point pulses. In Proceedings of the 27th Annual Meeting of ISMRM Montr\u00e9al Qu\u00e9bec Canada 2019. p. 4626."},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2024.03.037"},{"key":"e_1_2_10_19_1","unstructured":"DingB RuaC CarlinJ et al.Parallel transmit (pTx) with online pulse design for task\u2010based fMRI at 7T. In Proceedings of the 28th Annual Meeting of ISMRM Virtual Conference 2020. p. 3883."},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21513"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25192"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26084"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2022.08.006"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24805"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.27001"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.28441"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.30212"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.30565"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1002\/cmr.a.21414"},{"key":"e_1_2_10_30_1","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1002\/mrm.20840","article-title":"Fast\u2010kz 3D tailored radiofrequency pulse for reduced B1 inhomogeneity","volume":"55","author":"Saekho S","year":"2006","journal-title":"Magn Reson Med"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21739"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.23270"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.447644"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22978"},{"key":"e_1_2_10_35_1","doi-asserted-by":"crossref","DOI":"10.1063\/1.2831927","article-title":"Symmetry in the design of NMR multiple\u2010pulse sequences","volume":"128","author":"Levitt MH","year":"2008","journal-title":"J Chem Phys"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.30007"},{"key":"e_1_2_10_37_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22927"},{"key":"e_1_2_10_38_1","unstructured":"International Electrotechnical Commission.Medical electrical equipment\u00a0\u2013\u00a0Part 2\u201333: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis. 2015. Available at:https:\/\/webstore.iec.ch\/publication\/22705. Accessed June 15 2022."},{"key":"e_1_2_10_39_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22423"},{"key":"e_1_2_10_40_1","unstructured":"Tomi\u2010TricotR SedlacikJ EndresJ et al.Fully integrated scanner implementation of direct signal control for 2D T2\u2010weighted TSE at ultra\u2010high field. In Proceedings of the 29th Annual Meeting and Exhibition of ISMRM & SMRT An Online Experience May 15\u201020 2021. p. 0621."},{"key":"e_1_2_10_41_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24153"},{"key":"e_1_2_10_42_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.24619"},{"key":"e_1_2_10_43_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.28478"},{"key":"e_1_2_10_44_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26586"},{"key":"e_1_2_10_45_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26614"},{"key":"e_1_2_10_46_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2019.116335"},{"key":"e_1_2_10_47_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20168"},{"key":"e_1_2_10_48_1","doi-asserted-by":"publisher","DOI":"10.1002\/1522-2594(200012)44:6<983::AID-MRM23>3.0.CO;2-8"},{"key":"e_1_2_10_49_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.zemedi.2008.01.008"},{"key":"e_1_2_10_50_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.30533"}],"container-title":["Magnetic Resonance in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.70068","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,6]],"date-time":"2025-12-06T17:49:19Z","timestamp":1765043359000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.70068"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,29]]},"references-count":49,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,2]]}},"alternative-id":["10.1002\/mrm.70068"],"URL":"https:\/\/doi.org\/10.1002\/mrm.70068","archive":["Portico"],"relation":{},"ISSN":["0740-3194","1522-2594"],"issn-type":[{"value":"0740-3194","type":"print"},{"value":"1522-2594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,29]]},"assertion":[{"value":"2025-01-27","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-08-18","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-29","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}