{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T05:10:52Z","timestamp":1789708252063,"version":"4.0.1"},"reference-count":53,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2025,10,3]],"date-time":"2025-10-03T00:00:00Z","timestamp":1759449600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000038","name":"Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","award":["RGPIN\u20102020\u201004414"],"award-info":[{"award-number":["RGPIN\u20102020\u201004414"]}],"id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000038","name":"Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","award":["RGPIN\u20102023\u201004079"],"award-info":[{"award-number":["RGPIN\u20102023\u201004079"]}],"id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance in Med"],"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Two\u2010dimensional (2D) transmit array spatial encoding (TRASE) previously required four radiofrequency fields; however, interactions between transmit (Tx) array elements caused significant challenges for 2D imaging. Here, we present a low\u2010cost, 2D radial encoding scheme (Radial TRASE) using a simplified two\u2010coil array.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Theory and Methods<\/jats:title>\n                    <jats:p>\n                      The system consists of two B\n                      <jats:sub>1<\/jats:sub>\n                      phase gradient coils capable of encoding any one transverse direction. By incremental mechanical rotation over a 90\u00b0 range, the encoding axis can be changed, allowing a complete radial k\u2010space acquisition. As a first demonstration, a wrist\u2010sized coil pair was experimentally verified on a 2\u2010MHz Halbach magnet, incorporating a static B\n                      <jats:sub>0<\/jats:sub>\n                      slice\u2010selection gradient. Although a high level of isolation is achievable geometrically, for a more robust implementation, we demonstrate the capability of active digital decoupling in eliminating residual coupling through a parallel\u2010transmit system.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Radial TRASE\u2013encoded images of water phantoms were acquired, achieving a resolution better than 1.67\u2009mm. Rotation of the Tx array was performed during the recovery period, which caused no imaging delays. All acquired images show minimal distortions, indicating the advantage of the simplified Tx array. The active digital decoupling technique is demonstrated to eliminate residual coupled currents, effectively increasing the isolation of the two\u2010coil array to \u221250\u2009dB. Sequential axial slice images were demonstrated using a uniform B\n                      <jats:sub>0<\/jats:sub>\n                      coil to shift the slice position.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>\n                      Two\u2010coil Radial TRASE can encode a 2D slice without rapidly switched B\n                      <jats:sub>0<\/jats:sub>\n                      gradients. Compared with previous three\u2010coil or four\u2010coil Cartesian TRASE, the design and isolation of the Tx array are significantly simplified.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/mrm.70104","type":"journal-article","created":{"date-parts":[[2025,10,3]],"date-time":"2025-10-03T07:35:09Z","timestamp":1759476909000},"page":"987-1001","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Radial TRASE:\n                    <scp>2D RF<\/scp>\n                    encoding through mechanical rotation and active digital decoupling"],"prefix":"10.1002","volume":"95","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1081-1902","authenticated-orcid":false,"given":"Christopher J.","family":"Sedlock","sequence":"first","affiliation":[{"name":"Department of Oncology University of Alberta   Edmonton Alberta Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aaron R.","family":"Purchase","sequence":"additional","affiliation":[{"name":"M Tech Research Canada Ltd.  Edmonton Alberta Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boguslaw","family":"Tomanek","sequence":"additional","affiliation":[{"name":"Department of Oncology University of Alberta   Edmonton Alberta Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9736-7487","authenticated-orcid":false,"given":"Jonathan C.","family":"Sharp","sequence":"additional","affiliation":[{"name":"Department of Oncology University of Alberta   Edmonton Alberta Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,10,3]]},"reference":[{"key":"e_1_2_9_2_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.26942"},{"key":"e_1_2_9_3_1","doi-asserted-by":"publisher","DOI":"10.3389\/fphy.2020.00172"},{"key":"e_1_2_9_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.26637"},{"key":"e_1_2_9_5_1","doi-asserted-by":"publisher","DOI":"10.13104\/imri.2019.23.3.179"},{"key":"e_1_2_9_6_1","doi-asserted-by":"publisher","DOI":"10.1126\/science.adm7168"},{"key":"e_1_2_9_7_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41551\u2010020\u201000641\u20105"},{"key":"e_1_2_9_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.30300"},{"key":"e_1_2_9_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2020.106829"},{"key":"e_1_2_9_10_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598\u2010022\u201017472\u2010w"},{"key":"e_1_2_9_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10334\u2010023\u201001090\u20102"},{"key":"e_1_2_9_12_1","doi-asserted-by":"publisher","DOI":"10.1038\/s44222\u2010023\u201000086\u2010w"},{"key":"e_1_2_9_13_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000836"},{"key":"e_1_2_9_14_1","unstructured":"U.S. Food and Drug Administration.Swoop point\u2010of\u2010care magnetic resonance imaging (POC MRI) scanner system. K211818.https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf21\/K211818.pdf. Published July 7 2021. Accessed April 10 2024"},{"key":"e_1_2_9_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22188"},{"key":"e_1_2_9_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2013.03.017"},{"key":"e_1_2_9_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.3023"},{"key":"e_1_2_9_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.28003"},{"key":"e_1_2_9_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2020.09.003"},{"key":"e_1_2_9_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2018.12.015"},{"key":"e_1_2_9_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2022.107361"},{"key":"e_1_2_9_22_1","doi-asserted-by":"publisher","DOI":"10.1109\/TASC.2003.812674"},{"key":"e_1_2_9_23_1","doi-asserted-by":"publisher","DOI":"10.1109\/TASC.2015.2477377"},{"key":"e_1_2_9_24_1","volume-title":"Handbook of MRI Pulse Sequences","author":"Bernstein MA","year":"2004"},{"key":"e_1_2_9_25_1","doi-asserted-by":"publisher","DOI":"10.1038\/242190a0"},{"key":"e_1_2_9_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910390221"},{"key":"e_1_2_9_27_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25147"},{"key":"e_1_2_9_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0079\u20106565(96)01035\u20107"},{"key":"e_1_2_9_29_1","doi-asserted-by":"publisher","DOI":"10.1006\/jmre.2001.2493"},{"key":"e_1_2_9_30_1","doi-asserted-by":"publisher","DOI":"10.1006\/jmra.1996.0185"},{"key":"e_1_2_9_31_1","doi-asserted-by":"publisher","DOI":"10.5194\/mr\u20102\u2010149\u20102021"},{"key":"e_1_2_9_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2016.04.005"},{"key":"e_1_2_9_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2019.106578"},{"key":"e_1_2_9_34_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.29294"},{"key":"e_1_2_9_35_1","article-title":"BSmag Toolbox User Manual. In Department of Electrical Engineering. April 2015, tech report: University of Applied Sciences D\u00fcsseldorf","author":"Qu\u00e9val L","year":"2015","journal-title":"Germany"},{"key":"e_1_2_9_36_1","unstructured":"KamonM SilveiraLM SmithhislerC WhiteJ.Fasthenry User's Guide. Research Laboratory of Electronics Department of Electrical Engineering and Computer Science Massachusetts Institute of Technology.1996."},{"key":"e_1_2_9_37_1","first-page":"170","volume-title":"Proceedings of the Annual Meeting of ISMRM, Berlin, Germany","author":"Vernickel P","year":"2007"},{"key":"e_1_2_9_38_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10334\u2010007\u20100089\u20108"},{"key":"e_1_2_9_39_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20011"},{"key":"e_1_2_9_40_1","doi-asserted-by":"publisher","DOI":"10.1097\/RMR.0000000000000204"},{"key":"e_1_2_9_41_1","unstructured":"Dual Shaft NEMA 24 CNC stepper motor 3.4nm (481.48oz.In) 60 \u00d7 60 \u00d7 100mm 8 wires. StepperOnline.https:\/\/www.omc\u2010stepperonline.com\/dual\u2010shaft\u2010nema\u201024\u2010cnc\u2010stepper\u2010motor\u20103\u20104nm\u2010481\u20106\u2010oz\u2010in\u201060x60x100mm\u20108\u2010wires\u201024hs39\u20103008d. Accessed May 17 2024"},{"key":"e_1_2_9_42_1","unstructured":"2\u2010Phase Hybrid Stepper Servo Driver HSS60.https:\/\/smart\u2010motor.en.made\u2010in\u2010china.com\/product\/tjnQLkWUIEch\/China\u20102\u2010Phase\u2010Hybrid\u2010Stepper\u2010Servo\u2010Driver\u2010HSS60.html. Accessed May 17 2024"},{"key":"e_1_2_9_43_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10334\u2010019\u201000763\u20101"},{"key":"e_1_2_9_44_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2019.06.005"},{"key":"e_1_2_9_45_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20151"},{"key":"e_1_2_9_46_1","doi-asserted-by":"publisher","DOI":"10.1364\/josaa.23.001048"},{"key":"e_1_2_9_47_1","doi-asserted-by":"publisher","DOI":"10.1002\/cmr.a.21256"},{"key":"e_1_2_9_48_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598\u2010017\u201012141\u20109"},{"key":"e_1_2_9_49_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598\u2010020\u201070698\u20104"},{"key":"e_1_2_9_50_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.28187"},{"key":"e_1_2_9_51_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.23008"},{"key":"e_1_2_9_52_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21202"},{"key":"e_1_2_9_53_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41467\u2010018\u201005585\u20108"},{"key":"e_1_2_9_54_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.29489"}],"container-title":["Magnetic Resonance in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.70104","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,6]],"date-time":"2025-12-06T17:49:21Z","timestamp":1765043361000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.70104"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,3]]},"references-count":53,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026,2]]}},"alternative-id":["10.1002\/mrm.70104"],"URL":"https:\/\/doi.org\/10.1002\/mrm.70104","archive":["Portico"],"relation":{},"ISSN":["0740-3194","1522-2594"],"issn-type":[{"value":"0740-3194","type":"print"},{"value":"1522-2594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,3]]},"assertion":[{"value":"2025-02-17","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-08","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-03","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}