{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,12]],"date-time":"2026-09-12T17:16:32Z","timestamp":1789233392300,"version":"build-2803163510"},"reference-count":26,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T00:00:00Z","timestamp":1759881600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance in Med"],"published-print":{"date-parts":[[2026,3]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>This study investigates the impact of lower limb amputation on radiofrequency (RF)\u2010induced heating of active and passive implantable medical devices (AIMDs and PIMDs) in a 1.5\u2009T MRI environment.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      High\u2010resolution anatomical models representing various body types and levels of amputation (below\u2010knee and above\u2010knee) were explored in the study. Full\u2010wave electromagnetic simulations were used to assess specific absorption rate (SAR) near modular hip prostheses. The RF\u2010induced lead\u2010tip heating for a clinically relevant peripheral nerve stimulation (PNS) device was evaluated following ISO 10974. Results were normalized using whole\u2010body SAR and averaged B1\n                      <jats:sub>+rms<\/jats:sub>\n                      . Experimental validation was performed using an anatomically inspired leg phantom with embedded metallic implants.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>SAR near passive implants increased with implant length and was influenced by the level of amputation. In general, more extensive amputations resulted in reduced SAR due to alterations in tissue geometry. For active implantable medical devices (AIMDs), temperature rise also decreased with greater amputation extent; however, localized heating effects were intensified near the amputation site. Phantom simulation results were in strong agreement with experimental measurements, supporting the accuracy of the modeling approach.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Limb amputation significantly alters RF field distribution, affecting RF\u2010induced heating near both active and passive implants. These results highlight the need for amputation\u2010specific safety assessments during MRI to ensure accurate evaluation of heating risks and implant compatibility in amputee patients.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/mrm.70123","type":"journal-article","created":{"date-parts":[[2025,10,9]],"date-time":"2025-10-09T05:30:32Z","timestamp":1759987832000},"page":"1726-1736","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Impact of Lower Limb Amputation on Implant Heating During 1.\n                    <scp>5\u2009T MRI<\/scp>\n                    : Assessment of Active and Passive Device"],"prefix":"10.1002","volume":"95","author":[{"given":"Ao","family":"Shen","sequence":"first","affiliation":[{"name":"Department of Electrical and Computer Engineering University of Houston  Houston Texas USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mir Khadiza","family":"Akter","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering University of Houston  Houston Texas USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ziyu","family":"Zuo","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering University of Houston  Houston Texas USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lingfei","family":"Zhang","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering University of Houston  Houston Texas USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianfeng","family":"Zheng","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering University of Houston  Houston Texas USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6854-9348","authenticated-orcid":false,"given":"Michael","family":"Steckner","sequence":"additional","affiliation":[{"name":"MKS Consulting  Beachwood Ohio USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mingtao","family":"Du","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering University of Houston  Houston Texas USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6944-2729","authenticated-orcid":false,"given":"Ji","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Electrical and Computer Engineering University of Houston  Houston Texas USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,10,8]]},"reference":[{"key":"e_1_2_8_2_1","volume-title":"MRI: Basic Principles and Applications","author":"Brown M. A.","year":"2011"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jceh.2015.08.001"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmrs.800"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/53\/15\/006"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/60\/17\/6833"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1109\/EMBC.2016.7591444"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/52\/22\/012"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/52\/4\/001"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejvs.2018.04.017"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.4103\/0972\u20106748.196041"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.13107\/jocr.2250\u20100685.510"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140\u20106736(18)31777\u2010X"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.crad.2007.04.018"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12891\u2010024\u201007342\u2010z"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIM.2020.2971292"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1093\/milmed\/usz114"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1111\/ner.12102"},{"key":"e_1_2_8_19_1","doi-asserted-by":"crossref","unstructured":"Standard Test Method for Measurement of Radio Frequency Induced Heating on or Near Passive Implants During Magnetic Resonance Imaging(2019) https:\/\/doi.org\/10.1520\/F2182\u201019E02.","DOI":"10.1520\/F2182"},{"key":"e_1_2_8_20_1","volume-title":"Safety and Biological Effects in MRI","author":"Shrivastava D.","year":"2020"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1109\/ISEMC.2017.8078006"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/59\/18\/5287"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pmr.2013.09.013"},{"key":"e_1_2_8_24_1","unstructured":"Medical Electrical Equipment \u2010 Part 2\u201333: Particular Requirements for the Basic Safety and Essential Performance of Magnetic Resonance Equipment for Medical Diagnosis accessed June 24 2025 https:\/\/webstore.iec.ch\/en\/publication\/67211."},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1088\/1361\u20106560\/aacbf2"},{"key":"e_1_2_8_26_1","unstructured":"ISO\/TS 10974:2018 accessed June 20 2025 https:\/\/www.iso.org\/standard\/65055.html."},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMTT.2020.3030789"}],"container-title":["Magnetic Resonance in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.70123","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,29]],"date-time":"2025-12-29T10:40:06Z","timestamp":1767004806000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.70123"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,8]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,3]]}},"alternative-id":["10.1002\/mrm.70123"],"URL":"https:\/\/doi.org\/10.1002\/mrm.70123","archive":["Portico"],"relation":{},"ISSN":["0740-3194","1522-2594"],"issn-type":[{"value":"0740-3194","type":"print"},{"value":"1522-2594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,8]]},"assertion":[{"value":"2025-06-30","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-22","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-08","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}