{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T05:12:11Z","timestamp":1775279531723,"version":"3.50.1"},"reference-count":33,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T00:00:00Z","timestamp":1770163200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,2,4]],"date-time":"2026-02-04T00:00:00Z","timestamp":1770163200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["GRK2260, BIOQIC"],"award-info":[{"award-number":["GRK2260, BIOQIC"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100019599","name":"European Partnership on Metrology","doi-asserted-by":"publisher","award":["22HLT02 A4IM"],"award-info":[{"award-number":["22HLT02 A4IM"]}],"id":[{"id":"10.13039\/100019599","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance in Med"],"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The goal of this study was to develop a 5\u2010min 3D MRA acquisition at 0.55\u2009T with predictable scan time, 100% data efficiency, and robust water\u2010fat separation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>For full data efficiency, the proposed method combined self\u2010gating with retrospective motion correction while ensuring a predictable 5\u2010min scan time. Water\u2010fat separation was implemented using a model\u2010based Dixon reconstruction. Evaluation in 18 volunteers compared results to navigator\u2010gated reference scans with nominal scan times of 5 and 10\u2009min via a Likert scale blinded expert rating. Susceptibility to irregular breathing patterns was also analyzed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The expert rating for image quality was 4.22 for the proposed method, 3.89 for the 5\u2010min navigator\u2010gated scan and 4.43 for the 10\u2010min navigator\u2010gated scan. Ranking the three methods revealed moderate inter\u2010rater reliability of 0.46, suggesting only minor differences. While navigator\u2010gated acquisitions deviated from the expected scan time by \u22122.26 to 2.86\u2009min and \u22123.91 to 4.54\u2009min for the 5\u2010 and 10\u2010min protocols respectively, the proposed method deviated only by \u22120.17 to 0.45\u2009min. The self\u2010gated method further avoided saturation artifacts from the cross\u2010beam navigator, allowing better distinction of the right pulmonary veins. Image quality for the proposed method was also less susceptible to irregular breathing patterns.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Whole\u2010thorax MRA acquisitions with water\u2010fat separation and predictable scan times were successfully acquired in 18 volunteers at 0.55\u2009T. The proposed method demonstrated on average better image quality than navigator\u2010gated acquisitions of the same nominal scan time while mitigating limitations of prospective navigator gating.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/mrm.70285","type":"journal-article","created":{"date-parts":[[2026,2,5]],"date-time":"2026-02-05T04:40:20Z","timestamp":1770266420000},"page":"3241-3252","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Respiratory Motion\u2010Corrected Model\u2010Based\n                    <scp>3D<\/scp>\n                    Water\u2010Fat\n                    <scp>MRA<\/scp>\n                    of the Thorax at 0.55\n                    <scp>T<\/scp>"],"prefix":"10.1002","volume":"95","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-3958-5933","authenticated-orcid":false,"given":"Robert","family":"Stoll","sequence":"first","affiliation":[{"name":"Department of Medical Engineering Technical University Berlin  Berlin Germany"},{"name":"Research &amp; Clinical Translation, Magnetic Resonance, Siemens Healthineers AG  Erlangen Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4355-8368","authenticated-orcid":false,"given":"Christoph","family":"Kolbitsch","sequence":"additional","affiliation":[{"name":"Physikalisch\u2010Technische Bundesanstalt (PTB)  Braunschweig and Berlin Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michaela","family":"Schmidt","sequence":"additional","affiliation":[{"name":"Research &amp; Clinical Translation, Magnetic Resonance, Siemens Healthineers AG  Erlangen Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0360-7233","authenticated-orcid":false,"given":"Marcel Dominik","family":"Nickel","sequence":"additional","affiliation":[{"name":"Research &amp; Clinical Translation, Magnetic Resonance, Siemens Healthineers AG  Erlangen Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1310-2631","authenticated-orcid":false,"given":"Tobias","family":"Schaeffter","sequence":"additional","affiliation":[{"name":"Department of Medical Engineering Technical University Berlin  Berlin Germany"},{"name":"Physikalisch\u2010Technische Bundesanstalt (PTB)  Braunschweig and Berlin Germany"},{"name":"Einstein Center Digital Future (ECDF)  Berlin Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3925-4441","authenticated-orcid":false,"given":"Daniel","family":"Giese","sequence":"additional","affiliation":[{"name":"Research &amp; Clinical Translation, Magnetic Resonance, Siemens Healthineers AG  Erlangen Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2026,2,4]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1186\/1532\u2010429X\u201013\u201019"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11547\u2010023\u201001752\u20100"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jocmr.2024.101469"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.198.1.8539406"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.24480"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22769"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.23027"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.30316"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.153.1.6089263"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.30139"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21580"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22563"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26392"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.29284"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20656"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21391"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21236"},{"key":"e_1_2_10_19_1","first-page":"3671","volume-title":"Proceedings of International Society for Magnetic Resonance in Medicine","author":"Stoll R.","year":"2025"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF01589116"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1109\/42.796284"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910330517"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522\u20102594(199911)42:5<952::AID\u2010MRM16>3.0.CO;2\u2010S"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22177"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.27949"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22679"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2010.08.011"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21479"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12968\u2010019\u20100554\u20103"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.25357"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25315"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.170.5.9574617"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000061951.81767.4E"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2017.02.003"}],"container-title":["Magnetic Resonance in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.70285","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/mrm.70285","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.70285","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,4]],"date-time":"2026-04-04T04:35:34Z","timestamp":1775277334000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.70285"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,4]]},"references-count":33,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,6]]}},"alternative-id":["10.1002\/mrm.70285"],"URL":"https:\/\/doi.org\/10.1002\/mrm.70285","archive":["Portico"],"relation":{},"ISSN":["0740-3194","1522-2594"],"issn-type":[{"value":"0740-3194","type":"print"},{"value":"1522-2594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,4]]},"assertion":[{"value":"2025-11-10","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-01-21","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-02-04","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}