{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T19:38:43Z","timestamp":1783021123953,"version":"3.54.6"},"reference-count":36,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2026,4,23]],"date-time":"2026-04-23T00:00:00Z","timestamp":1776902400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,4,23]],"date-time":"2026-04-23T00:00:00Z","timestamp":1776902400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/501100005089","name":"Natural Science Foundation of Beijing Municipality","doi-asserted-by":"publisher","award":["L252048"],"award-info":[{"award-number":["L252048"]}],"id":[{"id":"10.13039\/501100005089","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance in Med"],"published-print":{"date-parts":[[2026,9]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To improve the imaging efficiency of 3D carotid simultaneous noncontrast angiography and intraplaque hemorrhage (SNAP) MRI by reconstruction of under\u2010sampled images and concurrent optimization of sampling masks for the two shots of SNAP respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A model\u2010based deep learning architecture (deepSNAP) was proposed to recover under\u2010sampled 3D carotid SNAP MRI. Sampling locations on the ky\u2013kz plane were parameterized to enable respective optimization of the sampling masks for the two shots. A dataset of 100 3D carotid SNAP MRI scans was utilized (80 training, 20 test). Image recovery performance was compared with established techniques under different acceleration factors. Lumen area measurement accuracy and intraplaque hemorrhage (IPH) identification were evaluated at 6\u00d7 acceleration. Prospective feasibility was assessed in 10 healthy volunteers with quantitative comparison against established methods.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      deepSNAP exhibited superior image recovery performance on the test set, surpassing all comparison methods. Optimized masks generated by deepSNAP improved reconstruction performance across all comparison methods. High agreement between reconstructed images and original images was observed for lumen area measurement (ICC\u2009=\u20090.995, 95% CI: 0.993\u20130.996) and IPH detection (Cohen's\n                      <jats:italic>\u03ba<\/jats:italic>\n                      \u2009=\u20090.976, 95% CI: 0.943\u20131.000). In the prospective experiment, deepSNAP achieved promising image quality and structural fidelity.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The deepSNAP model achieved under\u2010sampled image reconstruction and simultaneous sampling mask optimization for SNAP, ensured the clinical practicability of the reconstructed images, and demonstrated preliminary technical feasibility in a prospective setting.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/mrm.70401","type":"journal-article","created":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T04:31:09Z","timestamp":1777005069000},"page":"1387-1400","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Reconstruction of Under\u2010Sampled Images and Concurrent Optimization of Sampling Masks for\n                    <scp>3D<\/scp>\n                    Carotid Simultaneous Non\u2010Contrast Angiography and\n                    <scp>intraPlaque<\/scp>\n                    Hemorrhage\n                    <scp>MRI<\/scp>\n                    With Model Based Deep Learning Architecture (\n                    <scp>deepSNAP<\/scp>\n                    )"],"prefix":"10.1002","volume":"96","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6846-2290","authenticated-orcid":false,"given":"Jiachen","family":"Ji","sequence":"first","affiliation":[{"name":"Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-8753-9100","authenticated-orcid":false,"given":"Chuyu","family":"Liu","sequence":"additional","affiliation":[{"name":"Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qinxin","family":"Wang","sequence":"additional","affiliation":[{"name":"Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuo","family":"Chen","sequence":"additional","affiliation":[{"name":"Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2500-1814","authenticated-orcid":false,"given":"Zhongsen","family":"Li","sequence":"additional","affiliation":[{"name":"Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Le","family":"He","sequence":"additional","affiliation":[{"name":"Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xihai","family":"Zhao","sequence":"additional","affiliation":[{"name":"Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rui","family":"Li","sequence":"additional","affiliation":[{"name":"Center for Biomedical Imaging Research, School of Biomedical Engineering, Tsinghua University  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,4,23]]},"reference":[{"key":"e_1_2_8_2_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.Str.31.6.1439"},{"key":"e_1_2_8_3_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.Str.0000204638.91099.91"},{"key":"e_1_2_8_4_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.Str.26.1.188"},{"key":"e_1_2_8_5_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910380302"},{"key":"e_1_2_8_6_1","doi-asserted-by":"publisher","DOI":"10.1093\/rheumatology\/ken215"},{"key":"e_1_2_8_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22142"},{"key":"e_1_2_8_8_1","doi-asserted-by":"publisher","DOI":"10.1161\/hc4201.097839"},{"key":"e_1_2_8_9_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.Cir.0000028591.44554.F9"},{"key":"e_1_2_8_10_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2441051769"},{"key":"e_1_2_8_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2007.09.064"},{"key":"e_1_2_8_12_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2522080792"},{"key":"e_1_2_8_13_1","doi-asserted-by":"publisher","DOI":"10.1161\/Circulationaha.104.504167"},{"key":"e_1_2_8_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcmg.2009.08.007"},{"key":"e_1_2_8_15_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2491071517"},{"key":"e_1_2_8_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2008.05.002"},{"key":"e_1_2_8_17_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.09090535"},{"key":"e_1_2_8_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24254"},{"key":"e_1_2_8_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330\u2010017\u20105096\u20101"},{"key":"e_1_2_8_20_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2017170526"},{"key":"e_1_2_8_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.25653"},{"key":"e_1_2_8_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.25815"},{"key":"e_1_2_8_23_1","doi-asserted-by":"publisher","DOI":"10.21037\/qims.2019.09.11"},{"key":"e_1_2_8_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24989"},{"key":"e_1_2_8_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26111"},{"key":"e_1_2_8_26_1","doi-asserted-by":"publisher","DOI":"10.1109\/Access.2016.2624938"},{"key":"e_1_2_8_27_1","doi-asserted-by":"publisher","DOI":"10.1109\/Tip.2017.2662206"},{"key":"e_1_2_8_28_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21391"},{"key":"e_1_2_8_29_1","doi-asserted-by":"publisher","DOI":"10.1109\/Tci.2020.3006727"},{"key":"e_1_2_8_30_1","doi-asserted-by":"publisher","DOI":"10.1109\/Tmi.2018.2865356"},{"key":"e_1_2_8_31_1","doi-asserted-by":"publisher","DOI":"10.1109\/Jstsp.2020.3004094"},{"key":"e_1_2_8_32_1","doi-asserted-by":"publisher","DOI":"10.1007\/978\u20103\u2010319\u201024574\u20104_28"},{"key":"e_1_2_8_33_1","doi-asserted-by":"publisher","DOI":"10.1109\/CVPR.2016.90"},{"key":"e_1_2_8_34_1","doi-asserted-by":"publisher","DOI":"10.1161\/Atvbaha.115.307043"},{"key":"e_1_2_8_35_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22539"},{"key":"e_1_2_8_36_1","doi-asserted-by":"publisher","DOI":"10.1109\/Msp.2007.914728"},{"key":"e_1_2_8_37_1","first-page":"389","volume-title":"2008 Ieee Conference on Computer Vision and Pattern Recognition","author":"Ma S. Q.","year":"2008"}],"container-title":["Magnetic Resonance in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.70401","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/mrm.70401","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.70401","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T18:37:31Z","timestamp":1783017451000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.70401"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,23]]},"references-count":36,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["10.1002\/mrm.70401"],"URL":"https:\/\/doi.org\/10.1002\/mrm.70401","archive":["Portico"],"relation":{},"ISSN":["0740-3194","1522-2594"],"issn-type":[{"value":"0740-3194","type":"print"},{"value":"1522-2594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,23]]},"assertion":[{"value":"2026-02-20","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-13","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-23","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}