{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T05:21:03Z","timestamp":1788153663612,"version":"build-2803163510"},"reference-count":62,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2026,7,26]],"date-time":"2026-07-26T00:00:00Z","timestamp":1785024000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,7,26]],"date-time":"2026-07-26T00:00:00Z","timestamp":1785024000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/501100001665","name":"Agence Nationale de la Recherche","doi-asserted-by":"publisher","award":["ANR\u201023\u2010CE17\u20100019\u201001"],"award-info":[{"award-number":["ANR\u201023\u2010CE17\u20100019\u201001"]}],"id":[{"id":"10.13039\/501100001665","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance in Med"],"published-print":{"date-parts":[[2026,11]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>The design of radiofrequency (RF) coils tailored for the target anatomy is necessary to overcome the transmit field homogeneity and penetration issues at Ultra\u2010High\u2010Field (UHF). For the spinal cord, the optimal design has not yet been determined. This work intends to demonstrate the added value of a pair of passive dipoles placed under a conventional thoracic spine 4\u2009\u00d7\u20092\u2010loop array.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The conventional loop array produces a broad transmit field with unnecessary lateral spread. To address this, two passive dipoles were incorporated and tuned out\u2010of\u2010phase to actively suppress these lateral side\u2010lobes and increase field penetration the spinal cord region. The design was numerically optimised using a homogeneous phantom, followed by human voxel model simulations to evaluate performance and specific absorption rate (SAR). Finally, a prototype was tested in a 7T scanner using a homogeneous phantom to acquire experimental  maps.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Human voxel model simulations demonstrated that the passive dipoles improve the  transmit field distribution and predicted a 35% gain in SAR efficiency in the spinal cord region. Correspondingly, phantom experiments showed a 25% gain in transmit efficiency and 15% gain in homogeneity in a selected region of interest compared to the loop\u2010array\u2010only reference.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Incorporating passive dipoles effectively suppresses unwanted lateral field spread, increasing penetration depth and  efficiency in the thoracic spinal cord region. While homogeneous phantom results offer proof of concept, numerical simulations suggest reliable performance in realistic spine anatomy as well as substantial SAR reduction.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/mrm.70517","type":"journal-article","created":{"date-parts":[[2026,7,27]],"date-time":"2026-07-27T05:05:29Z","timestamp":1785128729000},"page":"2539-2552","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Enhanced Transmit Efficiency of a Loop Array Combined With Out\u2010of\u2010Phase Passive Dipoles for Thoracic Spinal Cord\n                    <scp>MRI<\/scp>\n                    at\n                    <scp>7T<\/scp>"],"prefix":"10.1002","volume":"96","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-1678-4764","authenticated-orcid":false,"given":"Hugo","family":"Amat","sequence":"first","affiliation":[{"name":"Multiwave Technologies  Marseille France"},{"name":"Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel  Marseille France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9195-7363","authenticated-orcid":false,"given":"Marc","family":"Dubois","sequence":"additional","affiliation":[{"name":"Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel  Marseille France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7189-4764","authenticated-orcid":false,"given":"Aurelien","family":"Destruel","sequence":"additional","affiliation":[{"name":"Aix Marseille Univ, CNRS, CRMBM  Marseille France"},{"name":"AP\u2010HM, H\u00f4pital de la Timone, CEMEREM  Marseille France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6104-2138","authenticated-orcid":false,"given":"Sajad","family":"Hosseinnezhadian","sequence":"additional","affiliation":[{"name":"Multiwave Technologies  Marseille France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Djamel","family":"Berrahou","sequence":"additional","affiliation":[{"name":"Multiwave Technologies  Marseille France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charles","family":"Betemps","sequence":"additional","affiliation":[{"name":"Aix Marseille Univ, CNRS, CRMBM  Marseille France"},{"name":"AP\u2010HM, H\u00f4pital de la Timone, CEMEREM  Marseille France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amira","family":"Trabelsi","sequence":"additional","affiliation":[{"name":"Multiwave Technologies  Marseille France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1502-0958","authenticated-orcid":false,"given":"David","family":"Bendahan","sequence":"additional","affiliation":[{"name":"Aix Marseille Univ, CNRS, CRMBM  Marseille France"},{"name":"AP\u2010HM, H\u00f4pital de la Timone, CEMEREM  Marseille France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0335-726X","authenticated-orcid":false,"given":"Stefan","family":"Enoch","sequence":"additional","affiliation":[{"name":"Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel  Marseille France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0850-1742","authenticated-orcid":false,"given":"Virginie","family":"Callot","sequence":"additional","affiliation":[{"name":"Aix Marseille Univ, CNRS, CRMBM  Marseille France"},{"name":"AP\u2010HM, H\u00f4pital de la Timone, CEMEREM  Marseille France"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Redha","family":"Abdeddaim","sequence":"additional","affiliation":[{"name":"Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel  Marseille France"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,7,26]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910030413"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2017.07.003"},{"key":"e_1_2_10_4_1","first-page":"301","volume-title":"Advances in Magnetic Resonance Technology and Applications","author":"Callot V.","year":"2023"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2016.08.055"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0730\u2010725X(01)00300\u20109"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.595000"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21751"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.25723"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neurol.2026.04.003"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.msard.2021.103436"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.0b013e31827597ae"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A7964"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1259\/0007\u20101285\u201040\u2010469\u201066"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clineuro.2020.106225"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0b013e3181b24ab7"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2009.2030170"},{"key":"e_1_2_10_18_1","volume-title":"Optimizing 7T Spine Array Design Through Offsetting of Transmit and Receive Elements and Quadrature Excitation","author":"Duan Q.","year":"2010"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2010.11.004"},{"key":"e_1_2_10_20_1","volume-title":"En Route to Clinical Ultrahigh Field Musculoskeletal MR Using Multi\u2010Purpose Transceiver RF Modules for Spine und Shoulder Imaging at 7.0 T","author":"Graessl A.","year":"2014"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25817"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2017.2788864"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1080\/09205071.2021.1871779"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.30551"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031\u20109155\/52\/7\/R01"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910160203"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.3313"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.30137"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10334\u2010011\u20100281\u20108"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22927"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.29708"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1109\/RBME.2024.3351713"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25596"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.23198"},{"key":"e_1_2_10_35_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.5002"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.26153"},{"key":"e_1_2_10_37_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.27485"},{"key":"e_1_2_10_38_1","doi-asserted-by":"publisher","DOI":"10.1155\/2020\/8886543"},{"key":"e_1_2_10_39_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.4106"},{"key":"e_1_2_10_40_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2021.3103654"},{"key":"e_1_2_10_41_1","volume-title":"Design and Demonstration of an Artificial Dielectric for 7T MRI","author":"Vorobyev V.","year":"2020"},{"key":"e_1_2_10_42_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598\u2010017\u201001932\u20109"},{"key":"e_1_2_10_43_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.30088"},{"key":"e_1_2_10_44_1","doi-asserted-by":"publisher","DOI":"10.1021\/acsami.4c10402"},{"key":"e_1_2_10_45_1","unstructured":"M. V.Vaidya S.Oh C. M.Collins D. K.Sodickson andR.Lattanzi \u201cManipulating B1 Spatial Distribution at 7 Tesla With Dielectric Pads at a Distance From a Transmit Surface Coil \u201d(2013)."},{"key":"e_1_2_10_46_1","doi-asserted-by":"publisher","DOI":"10.3390\/s24072250"},{"key":"e_1_2_10_47_1","volume-title":"Wireless Split Ring Resonator Metasurface Enhances Transmission Efficiency of Surface Loop Arrays at 7T","author":"Saha N. M.","year":"2024"},{"key":"e_1_2_10_48_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.3356"},{"key":"e_1_2_10_49_1","first-page":"1516","volume-title":"Distributed Capacitors for MR\u2010Receive\u2010Coils: Theory and Method","author":"Pannicke E.","year":"2021"},{"key":"e_1_2_10_50_1","doi-asserted-by":"publisher","DOI":"10.1142\/p759"},{"key":"e_1_2_10_51_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022\u20102364(83)90333\u20105"},{"key":"e_1_2_10_52_1","doi-asserted-by":"publisher","DOI":"10.1002\/cmr.b.20008"},{"key":"e_1_2_10_53_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.1144020"},{"key":"e_1_2_10_54_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1092"},{"key":"e_1_2_10_55_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22423"},{"key":"e_1_2_10_56_1","first-page":"2828","volume-title":"B1 Mapping of an 8\u2010Channel TX\u2010Array Over a Human\u2010Head\u2010Like Volume in Less Than 2 Minutes: The XEP Sequence","author":"Amadon A.","year":"2010"},{"key":"e_1_2_10_57_1","doi-asserted-by":"publisher","DOI":"10.1002\/cmr.b.21319"},{"key":"e_1_2_10_58_1","first-page":"2816","volume-title":"Why Does the Radiative Antenna Have No B1 Twisting at 7T? Framework for and Applications of a Conceptual \u201cMirror Current\u201d Model of Coil\u2010Tissue Interactions","author":"Zhang B.","year":"2012"},{"key":"e_1_2_10_59_1","doi-asserted-by":"publisher","DOI":"10.2183\/pjab1912.2.49"},{"key":"e_1_2_10_60_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.30617"},{"key":"e_1_2_10_61_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10334\u2010022\u201001007\u20105"},{"key":"e_1_2_10_62_1","doi-asserted-by":"publisher","DOI":"10.1109\/TAP.2022.3195515"},{"key":"e_1_2_10_63_1","doi-asserted-by":"publisher","DOI":"10.1109\/TAP.2018.2794400"}],"container-title":["Magnetic Resonance in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.70517","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/mrm.70517","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.70517","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T04:51:45Z","timestamp":1788151905000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.70517"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,26]]},"references-count":62,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,11]]}},"alternative-id":["10.1002\/mrm.70517"],"URL":"https:\/\/doi.org\/10.1002\/mrm.70517","archive":["Portico"],"relation":{},"ISSN":["0740-3194","1522-2594"],"issn-type":[{"value":"0740-3194","type":"print"},{"value":"1522-2594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,26]]},"assertion":[{"value":"2026-03-03","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-06","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-26","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}