{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T05:21:10Z","timestamp":1788153670673,"version":"build-2803163510"},"reference-count":40,"publisher":"Wiley","license":[{"start":{"date-parts":[[2026,8,30]],"date-time":"2026-08-30T00:00:00Z","timestamp":1788048000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2026,8,30]],"date-time":"2026-08-30T00:00:00Z","timestamp":1788048000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Magnetic Resonance in Med"],"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>\n                      To determine human blood longitudinal relaxation time (T\n                      <jats:sub>1<\/jats:sub>\n                      ) ex vivo at 5\u2009T using modified Look\u2010Locker inversion recovery (MOLLI), and to evaluate its dependence on hematocrit (Hct) and oxygenation (\n                      <jats:italic>Y<\/jats:italic>\n                      ).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      A MOLLI 5(3)3 protocol was simulated across T\n                      <jats:sub>1<\/jats:sub>\n                      values of 1000\u20133000\u2009ms to optimize the sampling interval. Aqueous gadolinium phantoms were scanned using optimized MOLLI and multi\u2010inversion\u2010time recovery spin echo (IR\u2010SE) acquisitions to derive a calibration equation. Arm venous blood from 27 healthy volunteers (mean age: 23.7\u2009\u00b1\u20094.3\u2009years; 10 males) was measured using optimized MOLLI, with three repetitions per sample. Hct and\n                      <jats:italic>Y<\/jats:italic>\n                      were measured by blood gas analysis, and their relationships with calibrated T\n                      <jats:sub>1<\/jats:sub>\n                      were evaluated.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The minimum root mean square error (RMSE) was obtained at a MOLLI sampling interval of 2000\u2009ms. In phantoms, MOLLI and IR\u2010SE T\n                      <jats:sub>1<\/jats:sub>\n                      showed a strong linear relationship: T\n                      <jats:sub>1,IR\u2010SE<\/jats:sub>\n                      \u2009=\u20091.185\u2009\u00d7\u2009T\n                      <jats:sub>1,MOLLI<\/jats:sub>\n                      \u201093.746 (\n                      <jats:italic>R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      \u2009=\u20090.998,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.0001). In blood, MOLLI showed high repeatability, with an overall repeatability RMSE of 1.80\u2009ms and a mean coefficient of variation of 0.10%\u2009\u00b1\u20090.08%. Calibrated blood T\n                      <jats:sub>1<\/jats:sub>\n                      was 1933.6\u2009\u00b1\u2009114.2\u2009ms, range 1727.0\u20132128.0\u2009ms. Blood 1\/T\n                      <jats:sub>1<\/jats:sub>\n                      dependence on Hct and\n                      <jats:italic>Y<\/jats:italic>\n                      : 1\/T\n                      <jats:sub>1<\/jats:sub>\n                      \u2009=\u20090.447\u20130.193\u2009\u00d7\u2009\n                      <jats:italic>Y<\/jats:italic>\n                      \u2009+\u20090.447\u2009\u00d7\u2009Hct\u2009+\u20090.150 (\n                      <jats:italic>Y<\/jats:italic>\n                      \u2009\u00d7\u2009Hct) (\n                      <jats:italic>R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      \u2009=\u20090.855,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.0001), yielding an arterial blood T\n                      <jats:sub>1<\/jats:sub>\n                      of 1971\u2009ms at\n                      <jats:italic>Y<\/jats:italic>\n                      \u2009=\u20090.98 and Hct\u2009=\u20090.42.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>\n                      Optimized and phantom calibrated MOLLI enabled rapid measurement of human ex vivo blood T\n                      <jats:sub>1<\/jats:sub>\n                      at 5\u2009T. Blood T\n                      <jats:sub>1<\/jats:sub>\n                      at 5\u2009T was higher than commonly reported adult values at 3\u2009T and varied with both Hct and\n                      <jats:italic>Y<\/jats:italic>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/mrm.70574","type":"journal-article","created":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T04:53:30Z","timestamp":1788152010000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Ex Vivo Measurement of Human Blood\n                    <scp>\n                      T\n                      <sub>1<\/sub>\n                    <\/scp>\n                    at\n                    <scp>5\u2009T<\/scp>\n                    : Dependence on Hematocrit and Oxygenation"],"prefix":"10.1002","author":[{"given":"Shuwan","family":"Yu","sequence":"first","affiliation":[{"name":"Center for Biomedical Imaging Research, School of Biomedical Engineering Tsinghua University  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuan","family":"Dong","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine Tsinghua University Hospital  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuxiao","family":"Gu","sequence":"additional","affiliation":[{"name":"Department of Automation Tsinghua University  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ne","family":"Yang","sequence":"additional","affiliation":[{"name":"Shanghai United Imaging Healthcare  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lele","family":"Ma","sequence":"additional","affiliation":[{"name":"Center for Biomedical Imaging Research, School of Biomedical Engineering Tsinghua University  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qingyu","family":"Xu","sequence":"additional","affiliation":[{"name":"Zhejiang Key Laboratory of Intelligent Sensing Technology and Advanced Medical Instrument, Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science Zhejiang University  Hangzhou China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ping","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine Tsinghua University Hospital  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Baoxin","family":"Zhou","sequence":"additional","affiliation":[{"name":"Department of Laboratory Medicine Tsinghua University Hospital  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuo","family":"Chen","sequence":"additional","affiliation":[{"name":"Shanghai United Imaging Healthcare  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yonglin","family":"Chen","sequence":"additional","affiliation":[{"name":"Center for Biomedical Imaging Research, School of Biomedical Engineering Tsinghua University  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3843-1020","authenticated-orcid":false,"given":"Dengrong","family":"Jiang","sequence":"additional","affiliation":[{"name":"National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering Shanghai Jiao Tong University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xihai","family":"Zhao","sequence":"additional","affiliation":[{"name":"Center for Biomedical Imaging Research, School of Biomedical Engineering Tsinghua University  Beijing China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9462-7768","authenticated-orcid":false,"given":"Zixuan","family":"Lin","sequence":"additional","affiliation":[{"name":"Zhejiang Key Laboratory of Intelligent Sensing Technology and Advanced Medical Instrument, Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science Zhejiang University  Hangzhou China"},{"name":"Children's Hospital, National Clinical Research Center for Child Health, Zhejiang University School of Medicine  Hangzhou China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,8,30]]},"reference":[{"issue":"1","key":"e_1_2_8_2_1","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1002\/mrm.1910230106","article-title":"Perfusion Imaging","volume":"23","author":"Detre J. A.","year":"1992","journal-title":"Magnetic Resonance in Medicine"},{"issue":"1","key":"e_1_2_8_3_1","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1002\/mrm.25197","article-title":"Recommended Implementation of Arterial Spin\u2010Labeled Perfusion MRI for Clinical Applications: A Consensus of the ISMRM Perfusion Study Group and the European Consortium for ASL in Dementia","volume":"73","author":"Alsop D. C.","year":"2015","journal-title":"Magnetic Resonance in Medicine"},{"issue":"2","key":"e_1_2_8_4_1","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1002\/mrm.10519","article-title":"Functional Magnetic Resonance Imaging Based on Changes in Vascular Space Occupancy","volume":"50","author":"Lu H.","year":"2003","journal-title":"Magnetic Resonance in Medicine"},{"issue":"2","key":"e_1_2_8_5_1","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1002\/mrm.1910170208","article-title":"Measurement of the Blood\u2010Brain Barrier Permeability and Leakage Space Using Dynamic MR Imaging. 1. Fundamental Concepts","volume":"17","author":"Tofts P. S.","year":"1991","journal-title":"Magnetic Resonance in Medicine"},{"issue":"3","key":"e_1_2_8_6_1","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1148\/radiology.181.3.1947077","article-title":"Fast Selective Black Blood MR Imaging","volume":"181","author":"Edelman R. R.","year":"1991","journal-title":"Radiology"},{"issue":"3","key":"e_1_2_8_7_1","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1002\/mrm.20178","article-title":"Determining the Longitudinal Relaxation Time (t1) of Blood at 3.0 Tesla","volume":"52","author":"Lu H.","year":"2004","journal-title":"Magnetic Resonance in Medicine"},{"issue":"5","key":"e_1_2_8_8_1","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1002\/mrm.22723","article-title":"Fast Measurement of Blood t1 in the Human Jugular Vein at 3 Tesla","volume":"65","author":"Qin Q.","year":"2011","journal-title":"Magnetic Resonance in Medicine"},{"issue":"6","key":"e_1_2_8_9_1","doi-asserted-by":"crossref","first-page":"2296","DOI":"10.1002\/mrm.26325","article-title":"Fast Measurement of Blood t(1) in the Human Carotid Artery at 3t: Accuracy, Precision, and Reproducibility","volume":"77","author":"Li W.","year":"2017","journal-title":"Magnetic Resonance in Medicine"},{"issue":"4","key":"e_1_2_8_10_1","doi-asserted-by":"crossref","first-page":"1730","DOI":"10.1002\/mrm.25775","article-title":"T1 and T2 Values of Human Neonatal Blood at 3 Tesla: Dependence on Hematocrit, Oxygenation, and Temperature","volume":"75","author":"Liu P.","year":"2016","journal-title":"Magnetic Resonance in Medicine"},{"issue":"4","key":"e_1_2_8_11_1","doi-asserted-by":"crossref","first-page":"1153","DOI":"10.1002\/mrm.24547","article-title":"Hematocrit and Oxygenation Dependence of Blood (1)h(2)o t(1) at 7 Tesla","volume":"70","author":"Grgac K.","year":"2013","journal-title":"Magnetic Resonance in Medicine"},{"issue":"4","key":"e_1_2_8_12_1","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.1002\/mrm.24550","article-title":"In Vivo Blood t(1) Measurements at 1.5 t, 3 t, and 7 t","volume":"70","author":"Zhang X.","year":"2013","journal-title":"Magnetic Resonance in Medicine"},{"issue":"3","key":"e_1_2_8_13_1","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1016\/j.mri.2012.08.008","article-title":"Measurement of t1 of Human Arterial and Venous Blood at 7t","volume":"31","author":"Rane S. D.","year":"2013","journal-title":"Magnetic Resonance Imaging"},{"issue":"2","key":"e_1_2_8_14_1","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1177\/0271678X15605856","article-title":"A General Model to Calculate the Spin\u2010Lattice (t1) Relaxation Time of Blood, Accounting for Haematocrit, Oxygen Saturation and Magnetic Field Strength","volume":"36","author":"Hales P. W.","year":"2016","journal-title":"Journal of Cerebral Blood Flow and Metabolism"},{"issue":"5","key":"e_1_2_8_15_1","doi-asserted-by":"crossref","first-page":"3222","DOI":"10.21037\/qims-22-945","article-title":"5t Magnetic Resonance Imaging: Radio Frequency Hardware and Initial Brain Imaging","volume":"13","author":"Wei Z.","year":"2023","journal-title":"Quantitative Imaging in Medicine and Surgery"},{"issue":"2","key":"e_1_2_8_16_1","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1002\/mrm.25135","article-title":"On the Accuracy of t1 Mapping: Searching for Common Ground","volume":"73","author":"Stikov N.","year":"2015","journal-title":"Magnetic Resonance in Medicine"},{"issue":"3","key":"e_1_2_8_17_1","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1002\/mrm.20602","article-title":"Full\u2010Brain t1 Mapping Through Inversion Recovery Fast Spin Echo Imaging With Time\u2010Efficient Slice Ordering","volume":"54","author":"Zhu D. C.","year":"2005","journal-title":"Magnetic Resonance in Medicine"},{"issue":"1","key":"e_1_2_8_18_1","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1002\/mrm.20110","article-title":"Modified Look\u2010Locker Inversion Recovery (Molli) for High\u2010Resolution t1 Mapping of the Heart","volume":"52","author":"Messroghli D. R.","year":"2004","journal-title":"Magnetic Resonance in Medicine"},{"issue":"1","key":"e_1_2_8_19_1","doi-asserted-by":"crossref","DOI":"10.1016\/j.jocmr.2025.101974","article-title":"Accurate Myocardial t1 Mapping at 5t Using an Improved Modified Look\u2010Locker Inversion Recovery Method: A Validation Study","volume":"28","author":"Ge L.","year":"2025","journal-title":"Journal of Cardiovascular Magnetic Resonance"},{"issue":"4","key":"e_1_2_8_20_1","first-page":"503","article-title":"The Effect of Changes to Molli Scheme on t1 Mapping and Extra Cellular Volume Calculation in Healthy Volunteers With 3 Tesla Cardiovascular Magnetic Resonance Imaging","volume":"5","author":"McDiarmid A. K.","year":"2015","journal-title":"Quantitative Imaging in Medicine and Surgery"},{"key":"e_1_2_8_21_1","first-page":"608","article-title":"Quantification of t1 Values by Snapshot\u2010Flash NMR Imaging","volume":"96","author":"Deichmann R.","year":"1992","journal-title":"Journal of Magnetic Resonance"},{"issue":"3","key":"e_1_2_8_22_1","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1002\/mrm.10370","article-title":"Effects of Hematocrit and Oxygen Saturation Level on Blood Spin\u2010Lattice Relaxation","volume":"49","author":"Silvennoinen M. J.","year":"2003","journal-title":"Magnetic Resonance in Medicine"},{"issue":"1","key":"e_1_2_8_23_1","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1002\/mrm.25875","article-title":"Quantitative Theory for the Longitudinal Relaxation Time of Blood Water","volume":"76","author":"Li W.","year":"2016","journal-title":"Magnetic Resonance in Medicine"},{"issue":"1","key":"e_1_2_8_24_1","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1073\/pnas.89.1.212","article-title":"Magnetic Resonance Imaging of Perfusion Using Spin Inversion of Arterial Water","volume":"89","author":"Williams D. S.","year":"1992","journal-title":"Proceedings of The National Academy of Sciences of The United States of America"},{"issue":"2","key":"e_1_2_8_25_1","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1097\/RMR.0b013e31821e570a","article-title":"Quantification Issues in Arterial Spin Labeling Perfusion Magnetic Resonance Imaging","volume":"21","author":"Wu W. C.","year":"2010","journal-title":"Topics in Magnetic Resonance Imaging"},{"issue":"1","key":"e_1_2_8_26_1","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1002\/mrm.22775","article-title":"Inflow\u2010Based Vascular\u2010Space\u2010Occupancy (Ivaso) MRI","volume":"66","author":"Hua J.","year":"2011","journal-title":"Magnetic Resonance in Medicine"},{"issue":"7","key":"e_1_2_8_27_1","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1038\/jcbfm.2010.16","article-title":"Absolute Arterial Cerebral Blood Volume Quantification Using Inflow Vascular\u2010Space\u2010Occupancy With Dynamic Subtraction Magnetic Resonance Imaging","volume":"30","author":"Donahue M. J.","year":"2010","journal-title":"Journal of Cerebral Blood Flow and Metabolism"},{"issue":"10","key":"e_1_2_8_28_1","doi-asserted-by":"crossref","first-page":"1313","DOI":"10.1002\/nbm.1693","article-title":"Measurement of Absolute Arterial Cerebral Blood Volume in Human Brain Without Using a Contrast Agent","volume":"24","author":"Hua J.","year":"2011","journal-title":"NMR in Biomedicine"},{"issue":"8","key":"e_1_2_8_29_1","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1002\/nbm.2905","article-title":"Noninvasive Functional Imaging of Cerebral Blood Volume With Vascular\u2010Space\u2010Occupancy (Vaso) MRI","volume":"26","author":"Lu H.","year":"2013","journal-title":"NMR in Biomedicine"},{"issue":"4","key":"e_1_2_8_30_1","doi-asserted-by":"crossref","first-page":"1507","DOI":"10.1002\/mrm.27141","article-title":"Non\u2010Contrast Mr Imaging of Blood\u2010Brain Barrier Permeability to Water","volume":"80","author":"Lin Z.","year":"2018","journal-title":"Magnetic Resonance in Medicine"},{"issue":"1","key":"e_1_2_8_31_1","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1002\/mrm.28687","article-title":"Noncontrast Assessment of Blood\u2010Brain Barrier Permeability to Water: Shorter Acquisition, Test\u2010Retest Reproducibility, and Comparison With Contrast\u2010Based Method","volume":"86","author":"Lin Z.","year":"2021","journal-title":"Magnetic Resonance in Medicine"},{"issue":"4","key":"e_1_2_8_32_1","doi-asserted-by":"crossref","first-page":"265","DOI":"10.2463\/mrms.11.265","article-title":"In Vivo Measurement of Longitudinal Relaxation Time of Human Blood by Inversion\u2010Recovery Fast Gradient\u2010Echo Mr Imaging at 3t","volume":"11","author":"Shimada K.","year":"2012","journal-title":"Magnetic Resonance in Medical Sciences"},{"issue":"4","key":"e_1_2_8_33_1","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1002\/mrm.1072","article-title":"Water Proton Mr Properties of Human Blood at 1.5 Tesla: Magnetic Susceptibility, t(1), t(2), t*(2), and Non\u2010Lorentzian Signal Behavior","volume":"45","author":"Spees W. M.","year":"2001","journal-title":"Magnetic Resonance in Medicine"},{"issue":"6","key":"e_1_2_8_34_1","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1118\/1.595994","article-title":"Magnetic Resonance Imaging of Stationary Blood: A Review","volume":"14","author":"Brooks R. A.","year":"1987","journal-title":"Medical Physics"},{"issue":"1","key":"e_1_2_8_35_1","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1002\/mrm.1910130112","article-title":"Magnetic Relaxation in Blood and Blood Clots","volume":"13","author":"Bryant R. G.","year":"1990","journal-title":"Magnetic Resonance in Medicine"},{"issue":"6","key":"e_1_2_8_36_1","doi-asserted-by":"crossref","first-page":"1313","DOI":"10.1002\/mrm.21792","article-title":"Field Strength Dependence of r1 and r2* Relaxivities of Human Whole Blood to Prohance, Vasovist, and Deoxyhemoglobin","volume":"60","author":"Blockley N. P.","year":"2008","journal-title":"Magnetic Resonance in Medicine"},{"issue":"4","key":"e_1_2_8_37_1","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1002\/mrm.1910340420","article-title":"Blood Oxygenation Dependence of t1 and t2 in the Isolated, Perfused Rabbit Heart at 4.7t","volume":"34","author":"Atalay M. K.","year":"1995","journal-title":"Magnetic Resonance in Medicine"},{"issue":"2","key":"e_1_2_8_38_1","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1002\/mrm.1910340215","article-title":"NMR Relaxation Rates and Blood Oxygenation Level","volume":"34","author":"Meyer M. E.","year":"1995","journal-title":"Magnetic Resonance in Medicine"},{"issue":"2","key":"e_1_2_8_39_1","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1152\/physrev.00035.2013","article-title":"Regulation of Increased Blood Flow (Hyperemia) to Muscles During Exercise: A Hierarchy of Competing Physiological Needs","volume":"95","author":"Joyner M. J.","year":"2015","journal-title":"Physiological Reviews"},{"issue":"6","key":"e_1_2_8_40_1","doi-asserted-by":"crossref","first-page":"1858","DOI":"10.1152\/japplphysiol.91102.2008","article-title":"Modeling Oxygenation in Venous Blood and Skeletal Muscle in Response to Exercise Using Near\u2010Infrared Spectroscopy","volume":"106","author":"Lai N.","year":"2009","journal-title":"Journal of Applied Physiology"},{"issue":"9","key":"e_1_2_8_41_1","doi-asserted-by":"crossref","first-page":"1727","DOI":"10.3174\/ajnr.A4793","article-title":"In Vivo t1 of Blood Measurements in Children With Sickle Cell Disease Improve Cerebral Blood Flow Quantification From Arterial Spin\u2010Labeling MRI","volume":"37","author":"V\u00e1clav\u016f L.","year":"2016","journal-title":"AJNR. American Journal of Neuroradiology"}],"container-title":["Magnetic Resonance in Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.70574","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/mrm.70574","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mrm.70574","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T04:53:43Z","timestamp":1788152023000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mrm.70574"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,30]]},"references-count":40,"alternative-id":["10.1002\/mrm.70574"],"URL":"https:\/\/doi.org\/10.1002\/mrm.70574","archive":["Portico"],"relation":{},"ISSN":["0740-3194","1522-2594"],"issn-type":[{"value":"0740-3194","type":"print"},{"value":"1522-2594","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,30]]},"assertion":[{"value":"2026-05-27","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-08-14","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-08-30","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"mrm.70574"}}