{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T04:08:47Z","timestamp":1780978127802,"version":"3.54.1"},"reference-count":30,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2011,11,8]],"date-time":"2011-11-08T00:00:00Z","timestamp":1320710400000},"content-version":"vor","delay-in-days":7,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Mount Sinai J Medicine"],"published-print":{"date-parts":[[2011,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Reduction in retained surgical items is an important part of any operating room patient\u2010safety effort. Any item used in an operation can result in a retained surgical item, but sponges are the most frequent and the abdomen is the most common location. Retained sponges can cause significant morbidity, and the costs associated with both prevention and treatment of retained surgical items, including legal costs, can be considerable. This review will examine counting, teamwork, radiography, and new technology as methods used to prevent retained surgical items. Even though none of these techniques individually is likely to completely prevent retained surgical items, when used together the numbers can be reduced. <jats:bold><jats:italic>Mt Sinai J Med 78:865\u2013871, 2011.<\/jats:italic><\/jats:bold> <jats:italic>\u00a9 2011 Mount Sinai School of Medicine<\/jats:italic><\/jats:p>","DOI":"10.1002\/msj.20299","type":"journal-article","created":{"date-parts":[[2011,11,9]],"date-time":"2011-11-09T00:52:39Z","timestamp":1320799959000},"page":"865-871","source":"Crossref","is-referenced-by-count":22,"title":["Prevention of Retained Surgical Items"],"prefix":"10.1002","volume":"78","author":[{"given":"David L.","family":"Feldman","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2011,11,8]]},"reference":[{"key":"e_1_2_8_2_2","doi-asserted-by":"publisher","DOI":"10.1177\/1553350610389196"},{"key":"e_1_2_8_3_2","volume-title":"Serious Reportable Events in Healthcare 2006 Update: A Consensus Report.","author":"National Quality Forum.","year":"2007"},{"key":"e_1_2_8_4_2","unstructured":"Centers for Medicare and Medicaid Services.Hospital\u2010acquired conditions.http:\/\/www.cms.gov\/HospitalAcqCond\/06_Hospital\u2010Acquired_Conditions.asp. Accessed April 7 2011."},{"key":"e_1_2_8_5_2","unstructured":"The Joint Commission.Sentinel event policy and procedures.http:\/\/www.jointcommission.org\/assets\/1\/6\/2011_CAMH_SE.pdf. Published January2011. Accessed April 7 2011."},{"key":"e_1_2_8_6_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMsa021721"},{"key":"e_1_2_8_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jamcollsurg.2007.12.047"},{"key":"e_1_2_8_8_2","doi-asserted-by":"publisher","DOI":"10.1097\/SLA.0b013e3180f633be"},{"key":"e_1_2_8_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/ACO.0b013e328324f82d"},{"key":"e_1_2_8_10_2","unstructured":"Office of Health Systems Management(New York State Department of Health).Quality & Safetynewsletter Winter2011."},{"key":"e_1_2_8_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jss.2006.08.001"},{"key":"e_1_2_8_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-199607000-00012"},{"key":"e_1_2_8_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.suc.2005.09.007"},{"key":"e_1_2_8_14_2","first-page":"39","article-title":"Beyond the count: preventing retention of foreign objects.","volume":"6","year":"2009","journal-title":"PA\u2010PSRS Patient Saf Advis"},{"key":"e_1_2_8_15_2","first-page":"e69","volume-title":"Association of Perioperative Registered Nurses, ed. Standards, Recommended Practices, and Guidelines","year":"2010"},{"key":"e_1_2_8_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2009.01.011"},{"key":"e_1_2_8_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/SLA.0b013e318181c9a3"},{"key":"e_1_2_8_18_2","first-page":"15","article-title":"American College of Surgeons. Statement on the prevention of retained foreign bodies after surgery.","volume":"90","year":"2005","journal-title":"Bull Am Coll Surg"},{"key":"e_1_2_8_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1553-7250(09)35016-3"},{"key":"e_1_2_8_20_2","doi-asserted-by":"publisher","DOI":"10.1067\/j.cpsurg.2007.03.002"},{"key":"e_1_2_8_21_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1990.01410150127025"},{"key":"e_1_2_8_22_2","first-page":"12","article-title":"The prevention of retained foreign bodies after surgery.","volume":"90","author":"Gibbs VC","year":"2005","journal-title":"Bull Amer Coll Surg"},{"key":"e_1_2_8_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/SLA.0b013e31812eeca5"},{"key":"e_1_2_8_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0001-2092(06)61347-1"},{"key":"e_1_2_8_25_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.2010.152"},{"key":"e_1_2_8_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.surg.2005.07.037"},{"key":"e_1_2_8_27_2","doi-asserted-by":"publisher","DOI":"10.1097\/SLA.0b013e3181656cd5"},{"key":"e_1_2_8_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1553-7250(11)37007-9"},{"key":"e_1_2_8_29_2","unstructured":"RuppCC KagariselMJ NelsonSM etal. Effectiveness of radio\u2010frequency surgical detection system to promote patient safety during an operative procedure by improving the process by which doctors and nurses track sponges prior to wound closure. Poster presented at: 96th Annual Clinical Congress of the American College of Surgeons; October2010; Washington DC."},{"key":"e_1_2_8_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjsurg.2010.05.001"},{"key":"e_1_2_8_31_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.141.7.659"}],"container-title":["Mount Sinai Journal of Medicine: A Journal of Translational and Personalized Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmsj.20299","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/msj.20299","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,20]],"date-time":"2023-11-20T15:08:25Z","timestamp":1700492905000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/msj.20299"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,11]]},"references-count":30,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2011,11]]}},"alternative-id":["10.1002\/msj.20299"],"URL":"https:\/\/doi.org\/10.1002\/msj.20299","archive":["Portico"],"relation":{},"ISSN":["0027-2507","1931-7581"],"issn-type":[{"value":"0027-2507","type":"print"},{"value":"1931-7581","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,11]]}}}