{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T09:58:36Z","timestamp":1760954316889},"reference-count":40,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2001,5,15]],"date-time":"2001-05-15T00:00:00Z","timestamp":989884800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Muscle and Nerve"],"published-print":{"date-parts":[[2001,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The purpose of this study was to determine the effect of three different stimulation patterns on repetitive knee movements. Each subject's quadriceps femoris was stimulated with: (1) a constant\u2010frequency train (CFT) with an interpulse interval (IPI) of 50 ms; (2) a variable\u2010frequency train (VFT)\u2014similar to the CFT, except with an initial doublet with an IPI of 5 ms; and (3) a doublet\u2010frequency train (DFT) with multiple doublets (doublet IPI 5 ms) separated by 50 ms, while the muscle was resisted by a load equal to 10% of the muscle's maximum voluntary isometric contraction. The muscle was stimulated while the knee moved through a 50\u00b0 arc of motion (90\u00b0 to 40\u00b0 of flexion). Testing was stopped when the subject failed to reach the target three consecutive times. Results showed that DFTs reached the target (mean \u00b1 SD) 36.4 \u00b1 14.4 times, followed by VFTs (25.4 \u00b1 17.9) and CFTs (17.4 \u00b1 11.9). The DFT was the best pattern for producing shortening contractions. The results suggest that DFTs may have significant benefits during clinical functional electrical stimulation. \u00a9 2001 John Wiley &amp; Sons, Inc. Muscle Nerve 24: 744\u2013752, 2001<\/jats:p>","DOI":"10.1002\/mus.1065","type":"journal-article","created":{"date-parts":[[2002,8,25]],"date-time":"2002-08-25T22:08:54Z","timestamp":1030313334000},"page":"744-752","source":"Crossref","is-referenced-by-count":27,"title":["A novel stimulation pattern improves performance during repetitive dynamic contractions"],"prefix":"10.1002","volume":"24","author":[{"given":"Maikutlo B.","family":"Kebaetse","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samuel C. K.","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stuart A.","family":"Binder\u2010Macleod","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2001,5,15]]},"reference":[{"key":"e_1_2_7_2_2","first-page":"5","article-title":"Electrically elicited quadriceps femoris muscle torque as a function of various electrode placements","volume":"3","author":"Barnett S","year":"1991","journal-title":"J Clin Electrophysiol"},{"key":"e_1_2_7_3_2","doi-asserted-by":"publisher","DOI":"10.1113\/jphysiol.1992.sp019076"},{"key":"e_1_2_7_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/0014-4886(79)90280-2"},{"key":"e_1_2_7_5_2","doi-asserted-by":"publisher","DOI":"10.1002\/mus.880140909"},{"key":"e_1_2_7_6_2","first-page":"117","article-title":"Use of a mathematical model to identify the optimal activation pattern for skeletal muscle during cardiomyoplasty","volume":"9","author":"Binder\u2010Macleod SA","year":"1999","journal-title":"Basic Appl Myol"},{"key":"e_1_2_7_7_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1996.80.6.2051"},{"key":"e_1_2_7_8_2","doi-asserted-by":"publisher","DOI":"10.1152\/jn.1998.79.4.1858"},{"key":"e_1_2_7_9_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1097-4598(199809)21:9<1145::AID-MUS5>3.0.CO;2-7"},{"key":"e_1_2_7_10_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1999.86.4.1337"},{"key":"e_1_2_7_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/0006-8993(76)90031-7"},{"key":"e_1_2_7_12_2","doi-asserted-by":"publisher","DOI":"10.1109\/10.32096"},{"key":"e_1_2_7_13_2","doi-asserted-by":"publisher","DOI":"10.1113\/jphysiol.1996.sp021259"},{"key":"e_1_2_7_14_2","doi-asserted-by":"publisher","DOI":"10.1113\/jphysiol.1930.sp002657"},{"key":"e_1_2_7_15_2","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1152\/jappl.2000.88.3.917","article-title":"Development of a mathematical model that predicts optimal muscle activation pattern","volume":"88","author":"Ding J","year":"2000","journal-title":"J Appl Physiol"},{"key":"e_1_2_7_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01756198"},{"key":"e_1_2_7_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/0079-6107(68)90023-0"},{"key":"e_1_2_7_18_2","first-page":"173","article-title":"The influence of a stimulation pattern on force and fatigue profiles in FES\u2010induced quadriceps contractions in paraplegics","volume":"4","author":"Franken HM","year":"1994","journal-title":"Basic Appl Myol"},{"key":"e_1_2_7_19_2","doi-asserted-by":"publisher","DOI":"10.1139\/h99-010"},{"key":"e_1_2_7_20_2","doi-asserted-by":"publisher","DOI":"10.1109\/10.398642"},{"key":"e_1_2_7_21_2","first-page":"329","volume-title":"Design and analysis: a researcher's handbook","author":"Keppel G","year":"1991"},{"key":"e_1_2_7_22_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF00239186"},{"key":"e_1_2_7_23_2","first-page":"113","volume-title":"Experimental design: procedures for behavioral sciences","author":"Kirk RE","year":"1995"},{"key":"e_1_2_7_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/0168-5597(92)90112-O"},{"key":"e_1_2_7_25_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1999.87.5.1758"},{"key":"e_1_2_7_26_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.2000.88.6.2166"},{"key":"e_1_2_7_27_2","first-page":"101","article-title":"Functional electrotherapy: stimulation of the peroneal nerve synchronized with the swing phase of gait of hemiplegic patients","volume":"42","author":"Liberson WT","year":"1961","journal-title":"Arch Phys Med Rehabil"},{"key":"e_1_2_7_28_2","first-page":"169","article-title":"\u201cMuscular wisdom\u201d that minimizes fatigue during prolonged effort in man: peak rates of motor units discharge and slowing of discharge during fatigue","volume":"39","author":"Marsden CD","year":"1983","journal-title":"Adv Neurol"},{"key":"e_1_2_7_29_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-198769050-00014"},{"key":"e_1_2_7_30_2","first-page":"115","volume-title":"Neuroprosthetics","author":"Maxwell DJ","year":"1996"},{"key":"e_1_2_7_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1350-4533(98)00041-1"},{"key":"e_1_2_7_32_2","doi-asserted-by":"publisher","DOI":"10.1085\/jgp.78.3.295"},{"key":"e_1_2_7_33_2","doi-asserted-by":"publisher","DOI":"10.1038\/sc.1987.52"},{"key":"e_1_2_7_34_2","first-page":"145","volume-title":"Foundations of clinical research: applications to practice","author":"Portney LG","year":"1993"},{"key":"e_1_2_7_35_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1997.82.4.1219"},{"key":"e_1_2_7_36_2","first-page":"56","article-title":"Functional electrical stimulation","volume":"3","author":"Smith B","year":"1997","journal-title":"Topics Spinal Cord Inj Rehabil"},{"key":"e_1_2_7_37_2","doi-asserted-by":"publisher","DOI":"10.1249\/00005768-199307000-00005"},{"key":"e_1_2_7_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/0006-8993(79)91019-9"},{"key":"e_1_2_7_39_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1997.83.2.444"},{"key":"e_1_2_7_40_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1994.76.6.2714"},{"key":"e_1_2_7_41_2","doi-asserted-by":"publisher","DOI":"10.1152\/jn.1980.43.5.1206"}],"container-title":["Muscle &amp; Nerve"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmus.1065","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mus.1065","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,8]],"date-time":"2023-10-08T19:10:06Z","timestamp":1696792206000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mus.1065"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,5,15]]},"references-count":40,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2001,6]]}},"alternative-id":["10.1002\/mus.1065"],"URL":"https:\/\/doi.org\/10.1002\/mus.1065","archive":["Portico"],"relation":{},"ISSN":["0148-639X","1097-4598"],"issn-type":[{"value":"0148-639X","type":"print"},{"value":"1097-4598","type":"electronic"}],"subject":[],"published":{"date-parts":[[2001,5,15]]}}}