{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,25]],"date-time":"2025-10-25T13:56:39Z","timestamp":1761400599059},"reference-count":23,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2011,12,21]],"date-time":"2011-12-21T00:00:00Z","timestamp":1324425600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Muscle and Nerve"],"published-print":{"date-parts":[[2012,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Introduction:<\/jats:title><jats:p>Near\u2010infrared spectroscopy (NIRS) is a non\u2010invasive technique used to measure tissue oxygenation. In this study we describe oxyneurography (ONG), a novel application of the NIRS technique in non\u2010invasive surface measurement of oxygenation in ulnar nerve.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods:<\/jats:title><jats:p>NIRS sensors were applied directly over the ulnar epicondylar groove to measure the ulnar nerve ONG index, a ratio of oxygenated over total hemoglobin content. Ulnar motor conduction studies were obtained in all subjects.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results:<\/jats:title><jats:p>The ONG index and ulnar motor conduction had a positive linear association. Ulnar motor conduction could be linearly predicted by the ONG index. The ONG index showed a sensitivity of 1.0 and a specificity of 0.852 for the presence of an ulnar neuropathy symptom. During limb ischemia, the ONG index gradually decreased.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions:<\/jats:title><jats:p>Oxyneurography can lead to the early detection of a compromise in a nerve's oxygenation status leading to neuropathy. Muscle Nerve 45:75\u201380, 2012<\/jats:p><\/jats:sec>","DOI":"10.1002\/mus.22251","type":"journal-article","created":{"date-parts":[[2011,8,2]],"date-time":"2011-08-02T20:40:41Z","timestamp":1312317641000},"page":"75-80","source":"Crossref","is-referenced-by-count":4,"title":["Oxyneurography: A new technique for the measurement of nerve oxygenation"],"prefix":"10.1002","volume":"45","author":[{"given":"Joe F.","family":"Jabre","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giovanna M.","family":"Squintani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kenneth K.H.","family":"Chui","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2011,12,21]]},"reference":[{"key":"e_1_2_6_2_2","unstructured":"JabreJF online website. The MyNorms.com page.http:\/\/www.mynorms.com. Updated June 25 2011(accessed June 25 2011)."},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1126\/science.929199"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1042\/CS20090220"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1117\/1.3499419"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2407-10-423"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/ACO.0b013e32833e1536"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.semperi.2009.10.005"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1177\/0003319710362975"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12028-009-9254-4"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1186\/cc8929"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2008.08.027"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1388-2457(10)60620-7"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aeg181"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1117\/12.252417"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.2001.90.2.511"},{"key":"e_1_2_6_17_2","doi-asserted-by":"publisher","DOI":"10.1002\/mus.20708"},{"key":"e_1_2_6_18_2","doi-asserted-by":"publisher","DOI":"10.1002\/1531-8249(199910)46:4<667::AID-ANA19>3.0.CO;2-D"},{"key":"e_1_2_6_19_2","first-page":"1723","article-title":"NIR light penetration depth in the rat peripheral nerve and brain cortex","author":"Abdo A","year":"2007","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1172\/JCI12188"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1038\/sj.mt.6300019"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1001\/archneur.58.5.761"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1136\/jnnp.26.5.385"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0363-5023(89)80048-6"}],"container-title":["Muscle &amp; Nerve"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmus.22251","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmus.22251","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mus.22251","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,21]],"date-time":"2023-11-21T06:03:13Z","timestamp":1700546593000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mus.22251"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,12,21]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2012,1]]}},"alternative-id":["10.1002\/mus.22251"],"URL":"https:\/\/doi.org\/10.1002\/mus.22251","archive":["Portico"],"relation":{},"ISSN":["0148-639X","1097-4598"],"issn-type":[{"value":"0148-639X","type":"print"},{"value":"1097-4598","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,12,21]]}}}