{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T23:22:34Z","timestamp":1794266554900,"version":"4.9.0"},"reference-count":15,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2014,11,18]],"date-time":"2014-11-18T00:00:00Z","timestamp":1416268800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Muscle and Nerve"],"published-print":{"date-parts":[[2015,1]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:p><jats:italic>Introduction<\/jats:italic>: The aim of this study was to localize the motor entry point (MEP) of the thyroarytenoid muscle. <jats:italic>Methods<\/jats:italic>: Eight cadaver larynges were dissected. A virtual plane was used to represent the MEP in a coordinate (X\/Y\/Z) system. The inferior border of the thyroid cartilage was linked to the center of the anterior arc of the cricoid cartilage (the Y\u2010axis). The X\u2010axis was set perpendicular to the Y\u2010axis; the Z\u2010axis passed through the posterior border of the thyroid lamina from the height of the insertion point. <jats:italic>Results<\/jats:italic>: The mean X, Y, and Z coordinates were 6.2 mm, 9.1 mm, and 11.0 mm, respectively. The calculated angles of the lateral and superior deflections were 29.4\u00b0 and 35.8\u00b0, respectively. The calculated insertion depth, that is, the distance from the insertion point to the MEP, was 15.6 mm. <jats:italic>Conclusions<\/jats:italic>: These results may help to improve the accuracy of needle insertion during diagnostic laryngeal electromyography or laryngeal electromyography\u2010guided injections. <jats:italic>Muscle Nerve<\/jats:italic> <jats:bold>51<\/jats:bold>: 72\u201375, 2015<\/jats:p>","DOI":"10.1002\/mus.24258","type":"journal-article","created":{"date-parts":[[2014,4,7]],"date-time":"2014-04-07T08:48:39Z","timestamp":1396860519000},"page":"72-75","source":"Crossref","is-referenced-by-count":3,"title":["Anatomical localization of the motor entry point in the thyroarytenoid muscle"],"prefix":"10.1002","volume":"51","author":[{"given":"Soo Yeon","family":"Kim","sequence":"first","affiliation":[{"name":"Department of Rehabilitation Medicine St. Paul's Hospital, College of Medicine, Catholic University of Korea Jeonnong\u2010Dong, Dongdaemoon\u2010Gu Seoul 130\u2010709 Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dae Heon","family":"Song","sequence":"additional","affiliation":[{"name":"Department of Rehabilitation Medicine St. Paul's Hospital, College of Medicine, Catholic University of Korea Jeonnong\u2010Dong, Dongdaemoon\u2010Gu Seoul 130\u2010709 Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Myung Eun","family":"Chung","sequence":"additional","affiliation":[{"name":"Department of Rehabilitation Medicine St. Paul's Hospital, College of Medicine, Catholic University of Korea Jeonnong\u2010Dong, Dongdaemoon\u2010Gu Seoul 130\u2010709 Republic of Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2014,11,18]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1093\/brain\/67.3.178"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1288\/00005537-195604000-00004"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1038\/177340a0"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1113\/expphysiol.1959.sp001380"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvoice.2011.04.003"},{"key":"e_1_2_6_7_1","first-page":"294","volume-title":"Anatomical guide for the electromyographer","author":"Perotto A","year":"1994"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1001\/archotol.134.4.380"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.moo.0000145959.50513.5e"},{"key":"e_1_2_6_10_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005537-199810000-00003"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1191\/0269215506cr931oa"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/00005537-200212000-00016"},{"key":"e_1_2_6_13_1","first-page":"71","volume-title":"Laryngeal electromyography","author":"Sataloff RT","year":"2006"},{"key":"e_1_2_6_14_1","first-page":"66","volume-title":"Neurologic disorders of the larynx","author":"Lovelace RE","year":"1992"},{"key":"e_1_2_6_15_1","first-page":"10","article-title":"Laryngeal electromyography: electrode guidance based on 3\u2010dimensional magnetic resonance tomography images of the larynx","volume":"6","author":"Strock C","year":"2012","journal-title":"J Voice"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/0196-0709(95)90008-X"}],"container-title":["Muscle &amp; Nerve"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmus.24258","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmus.24258","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mus.24258","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,4]],"date-time":"2023-10-04T00:18:17Z","timestamp":1696378697000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mus.24258"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,11,18]]},"references-count":15,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2015,1]]}},"alternative-id":["10.1002\/mus.24258"],"URL":"https:\/\/doi.org\/10.1002\/mus.24258","archive":["Portico"],"relation":{},"ISSN":["0148-639X","1097-4598"],"issn-type":[{"value":"0148-639X","type":"print"},{"value":"1097-4598","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,11,18]]}}}