{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T10:56:58Z","timestamp":1790420218088,"version":"4.1.0"},"reference-count":28,"publisher":"Wiley","issue":"6","license":[{"start":{"date-parts":[[2017,3,21]],"date-time":"2017-03-21T00:00:00Z","timestamp":1490054400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100004702","name":"University of Genoa","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004702","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Muscle and Nerve"],"published-print":{"date-parts":[[2017,6]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:sec><jats:title>Introduction<\/jats:title><jats:p>We prospectively compared ultrasound (US) and MRI in patients with common fibular neuropathy.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Forty adult patients with clinical suspicion of common fibular neuropathy and 40 healthy controls underwent both US and MRI. US and MRI datasets were randomized for prospective reading.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The overall sensitivity of US and MRI for diagnosing fibular neuropathy was 90% (95% confidence interval [CI], 79.7%\u201097.3%) and 87.5% (95% CI, 71.55%\u201093.1%), respectively. The overall specificity of US and MRI was 92% (95% CI, 77.45%\u201096.1%) and 85% (95% CI, 73.3%\u201094.4%), respectively. The overall sensitivity and specificity of US combined with MRI were 94% (95% CI, 0.80%\u20100.99%) and 84% (95% CI, 0.70%\u20100.91%), respectively. Overall intra\u2010 and inter\u2010observer agreements among 3 readers were 0.76% (95% CI, 0.62%\u20100.85%) and 0.74% (95% CI, 0.65%\u20100.81%).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>US diagnostic accuracy for common fibular neuropathy was slightly higher than that of MRI. <jats:italic>Muscle Nerve<\/jats:italic> <jats:bold>55<\/jats:bold>: 849\u2013857, 2017<\/jats:p><\/jats:sec>","DOI":"10.1002\/mus.25418","type":"journal-article","created":{"date-parts":[[2016,9,26]],"date-time":"2016-09-26T23:18:41Z","timestamp":1474931921000},"page":"849-857","source":"Crossref","is-referenced-by-count":28,"title":["Ultrasound versus MRI in common fibular neuropathy"],"prefix":"10.1002","volume":"55","author":[{"given":"Bianca","family":"Bignotti","sequence":"first","affiliation":[{"name":"Department of Health Sciences (DISSAL) University of Genoa Genoa Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Assini","sequence":"additional","affiliation":[{"name":"Ente Ospedaliero Ospedali Galliera Genova Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alessio","family":"Signori","sequence":"additional","affiliation":[{"name":"Department of Health Sciences (DISSAL) University of Genoa Genoa Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlo","family":"Martinoli","sequence":"additional","affiliation":[{"name":"Department of Health Sciences (DISSAL) University of Genoa Genoa Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alberto","family":"Tagliafico","sequence":"additional","affiliation":[{"name":"Institute of Anatomy, Department of Experimental Medicine (DIMES), University of Genoa Via L.B. Alberti 2 16132 Genoa Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2017,3,21]]},"reference":[{"key":"e_1_2_6_2_1","volume-title":"High\u2010resolution sonography of the peripheral nervous system","author":"Peer S","year":"2010"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-540-28163-4"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0733-8619(05)70153-5"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1002\/mus.23729"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinph.2013.11.041"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/mus.24879"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/mus.23417"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00256-011-1146-y"},{"key":"e_1_2_6_10_1","first-page":"41","volume-title":"Magnetic resonance imaging of the skeletal musculature","author":"Martinoli C","year":"2014"},{"key":"e_1_2_6_11_1","first-page":"27","volume-title":"Magnetic resonance imaging of the skeletal musculature","author":"Tagliafico A","year":"2014"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1097\/RCT.0b013e31825dcfba"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2265.2008.03468.x"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1530\/EJE-08-0327"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1210\/jc.2007-1719"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.7863\/jum.2013.32.3.457"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1002\/mus.24274"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2402"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-014-3402-8"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultrasmedbio.2010.07.009"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.2307\/2531595"},{"key":"e_1_2_6_22_1","first-page":"31","article-title":"Statistics with confidence \u2013 confidence intervals and statistical guidelines","author":"Altman DG","year":"1989","journal-title":"BMJ"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2521081614"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.11111060"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-014-3498-x"},{"key":"e_1_2_6_26_1","unstructured":"Fourth International Conference and Course on Neuromuscular Ultrasound. Available atwww.ispni.org. Accessed March 2014."},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00256-010-1050-x"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultrasmedbio.2010.07.009"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000000068"}],"container-title":["Muscle &amp; Nerve"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmus.25418","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fmus.25418","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mus.25418","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/mus.25418","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mus.25418","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,6]],"date-time":"2023-09-06T03:39:49Z","timestamp":1693971589000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mus.25418"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3,21]]},"references-count":28,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2017,6]]}},"alternative-id":["10.1002\/mus.25418"],"URL":"https:\/\/doi.org\/10.1002\/mus.25418","archive":["Portico"],"relation":{},"ISSN":["0148-639X","1097-4598"],"issn-type":[{"value":"0148-639X","type":"print"},{"value":"1097-4598","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,3,21]]}}}