{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T22:20:02Z","timestamp":1792794002844,"version":"4.5.0"},"reference-count":32,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2023,11,17]],"date-time":"2023-11-17T00:00:00Z","timestamp":1700179200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Muscle and Nerve"],"published-print":{"date-parts":[[2024,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Phrenic nerve conduction studies (NCSs) and needle electromyography (EMG) can provide important information on the underlying pathophysiology in patients presenting with unexplained shortness of breath, failure to wean from the ventilator, or consideration of phrenic nerve pacemaker implantation. However, these techniques are often technically challenging, require experience, can lack sensitivity and specificity, and, in the case of diaphragm EMG, involve some degree of risk. Diagnostic high\u2010resolution ultrasound has been introduced in recent years as an adjuvant technique readily available at the bedside that can increase the overall sensitivity and specificity of the neurophysiologic evaluation of respiratory symptoms. Two\u2010dimensional ultrasound in the zone of apposition can identify atrophy and evaluate contractility of the diaphragm, in addition to localizing a safe zone for needle EMG. M\u2010mode ultrasound can identify decreased excursion or paradoxical motion of the diaphragm and can increase the reliability of phrenic NCSs. When used in combination, ultrasound, phrenic NCSs and EMG of the diaphragm can differentiate neuropathic, myopathic, and central disorders, and can offer aid in prognosis that is difficult to arrive at solely from clinical examination. This article will review techniques to successfully perform phrenic NCSs, needle EMG of the diaphragm, and ultrasound of the diaphragm. The discussion will include technical pitfalls and clinical pearls as well as future directions and clinical indications.<\/jats:p>","DOI":"10.1002\/mus.27998","type":"journal-article","created":{"date-parts":[[2023,11,17]],"date-time":"2023-11-17T09:32:43Z","timestamp":1700213563000},"page":"18-28","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Electrodiagnostic and ultrasound evaluation of respiratory weakness"],"prefix":"10.1002","volume":"69","author":[{"given":"Andrea J.","family":"Boon","sequence":"first","affiliation":[{"name":"Department of Physical Medicine and Rehabilitation Mayo Clinic  Rochester Minnesota USA"},{"name":"Department of Neurology Mayo Clinic  Rochester Minnesota USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William J.","family":"Litchy","sequence":"additional","affiliation":[{"name":"Department of Neurology Mayo Clinic  Rochester Minnesota USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2023,11,17]]},"reference":[{"key":"e_1_2_13_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-323-91532-8.00003-3"},{"key":"e_1_2_13_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jsmc.2020.08.002"},{"key":"e_1_2_13_4_1","first-page":"20","volume-title":"Neurology of Breathing","author":"Bolton CF","year":"2004"},{"key":"e_1_2_13_5_1","first-page":"597","volume-title":"Hollinshead's Textbook of Anatomy","author":"Rosse C","year":"1997"},{"key":"e_1_2_13_6_1","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.bmb.a071628"},{"key":"e_1_2_13_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/mus.880160802"},{"key":"e_1_2_13_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/mus.20887"},{"key":"e_1_2_13_9_1","unstructured":"American Association of Neuromuscular and Electrodiagnostic Medicine. Risks in Electrodiagnostic Medicine.Position Statement.2020https:\/\/www.aanem.org\/Advocacy\/Position-Statements\/Risks-in-Electrodiagnostic-MedicineAccessed May 9 2023."},{"key":"e_1_2_13_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/mus.23953"},{"key":"e_1_2_13_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/mus.23702"},{"key":"e_1_2_13_12_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.13-2306"},{"key":"e_1_2_13_13_1","doi-asserted-by":"publisher","DOI":"10.1212\/WNL.0000000000000841"},{"key":"e_1_2_13_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/mus.25429"},{"key":"e_1_2_13_15_1","doi-asserted-by":"publisher","DOI":"10.2519\/jospt.2013.4931"},{"key":"e_1_2_13_16_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMe0801226"},{"key":"e_1_2_13_17_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.chest.2020.12.003"},{"key":"e_1_2_13_18_1","doi-asserted-by":"publisher","DOI":"10.5005\/jp-journals-10071-24125"},{"key":"e_1_2_13_19_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.08-1541"},{"key":"e_1_2_13_20_1","doi-asserted-by":"publisher","DOI":"10.1213\/ANE.0b013e3181d5e4d8"},{"key":"e_1_2_13_21_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.08-1531"},{"key":"e_1_2_13_22_1","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0b013e31822a55e9"},{"key":"e_1_2_13_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/mus.24059"},{"key":"e_1_2_13_24_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12871-016-0201-6"},{"key":"e_1_2_13_25_1","doi-asserted-by":"publisher","DOI":"10.3892\/etm.2013.1133"},{"key":"e_1_2_13_26_1","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.202107-1605ED"},{"key":"e_1_2_13_27_1","doi-asserted-by":"publisher","DOI":"10.1002\/mus.880150608"},{"key":"e_1_2_13_28_1","doi-asserted-by":"publisher","DOI":"10.1002\/mus.24883"},{"key":"e_1_2_13_29_1","first-page":"8","article-title":"The electromyographic examination of the diaphragm","volume":"7","author":"Koepke GH","year":"1960","journal-title":"Bull Am Assoc Electromyogr Electrodiagn"},{"key":"e_1_2_13_30_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000214941.46628.1c"},{"key":"e_1_2_13_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pmrj.2008.09.002"},{"key":"e_1_2_13_32_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pmrj.2008.09.001"},{"key":"e_1_2_13_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/mus.23671"}],"container-title":["Muscle &amp; Nerve"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/mus.27998","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,11]],"date-time":"2024-01-11T04:17:24Z","timestamp":1704946644000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/mus.27998"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,17]]},"references-count":32,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,1]]}},"alternative-id":["10.1002\/mus.27998"],"URL":"https:\/\/doi.org\/10.1002\/mus.27998","archive":["Portico"],"relation":{},"ISSN":["0148-639X","1097-4598"],"issn-type":[{"value":"0148-639X","type":"print"},{"value":"1097-4598","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,17]]},"assertion":[{"value":"2023-10-20","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-10-23","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-11-17","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}