{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T02:27:25Z","timestamp":1740104845562,"version":"3.37.3"},"reference-count":3,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2017,11,13]],"date-time":"2017-11-13T00:00:00Z","timestamp":1510531200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Neurourology and Urodynamics"],"published-print":{"date-parts":[[2018,3]]},"abstract":"<jats:sec><jats:title>Aims<\/jats:title><jats:p>To present a narrated video designed to demonstrate the steps involved in a laparoscopic mesh repair of a labial hernia.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This was in a 76\u2010year\u2010old woman who presented with a small bowel hernia in to her left labium majus. In 2014 she had a robotically assisted radical cystectomy for bladder cancer with anterior exenteration. She developed the hernia in February 2015 and initially a vaginal approach was attempted to repair the hernia (with layered non\u2010absorbable sutures to close the fascia over the defect) at her local hospital, although this was unsuccessful. A laparoscopic repair with mesh on the 10 May 2016 was undertaken at our unit.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>This was a complex case requiring a multi disciplinary approach and individualised care. The need for a mesh was obvious: however, the use of both synthetic and biological meshes to achieve an optimum result was unique and highly successful.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>In this instance a minimally invasive laparoscopic approach where initial adhesiolysis was performed and then a synthetic mesh sandwiched in between two biological porcine meshes provided a unique management solution. The patient was seen 8 weeks post operatively and at 14 months after the procedure. She had complete resolution of her symptoms with no residual hernia.<\/jats:p><\/jats:sec>","DOI":"10.1002\/nau.23440","type":"journal-article","created":{"date-parts":[[2017,11,13]],"date-time":"2017-11-13T09:26:40Z","timestamp":1510565200000},"page":"1178-1179","source":"Crossref","is-referenced-by-count":0,"title":["Laparoscopic mesh repair of a labial hernia"],"prefix":"10.1002","volume":"37","author":[{"given":"Philippe","family":"Grange","sequence":"first","affiliation":[{"name":"King's College Hospital London England"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6784-4473","authenticated-orcid":false,"given":"Fevzi","family":"Shakir","sequence":"additional","affiliation":[{"name":"Royal Free Hospital Hampstead London England"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ganesh","family":"Thiagamoorthy","sequence":"additional","affiliation":[{"name":"King's College Hospital London England"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"George","family":"Araklitis","sequence":"additional","affiliation":[{"name":"King's College Hospital London England"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dudley","family":"Robinson","sequence":"additional","affiliation":[{"name":"King's College Hospital London England"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Linda","family":"Cardozo","sequence":"additional","affiliation":[{"name":"King's College Hospital London England"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2017,11,13]]},"reference":[{"key":"e_1_2_4_2_1","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2168.1999.01139.x"},{"key":"e_1_2_4_3_1","doi-asserted-by":"publisher","DOI":"10.1002\/1097-0142(19921215)70:12<2835::AID-CNCR2820701219>3.0.CO;2-U"},{"key":"e_1_2_4_4_1","doi-asserted-by":"publisher","DOI":"10.1590\/s1677-5538.ibju.2016.0534"}],"container-title":["Neurourology and Urodynamics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fnau.23440","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/nau.23440","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,24]],"date-time":"2023-09-24T16:08:28Z","timestamp":1695571708000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/nau.23440"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11,13]]},"references-count":3,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018,3]]}},"alternative-id":["10.1002\/nau.23440"],"URL":"https:\/\/doi.org\/10.1002\/nau.23440","archive":["Portico"],"relation":{},"ISSN":["0733-2467","1520-6777"],"issn-type":[{"type":"print","value":"0733-2467"},{"type":"electronic","value":"1520-6777"}],"subject":[],"published":{"date-parts":[[2017,11,13]]}}}