{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T06:52:17Z","timestamp":1785826337156,"version":"3.56.0"},"reference-count":43,"publisher":"Wiley","license":[{"start":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T00:00:00Z","timestamp":1785715200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"},{"start":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T00:00:00Z","timestamp":1785715200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Neurourology and Urodynamics"],"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction<\/jats:title>\n                    <jats:p>For more than four decades, the AMS\u2010800 has remained the clinical benchmark device for the treatment of male stress urinary incontinence (SUI). Although it remains the gold standard for male SUI, the AMS\u2010800 has continued to have limitations such as suboptimal post\u2010operative continence rates, fixed hydraulic pressure, need for manual pump use, revision burden, and risk of urethral atrophy and erosion. These limitations have influenced a new generation of AUS devices. This review summarizes commercially available, early\u2010development, discontinued, and emerging AUS devices, with a focus on how new designs address limitations of prior devices.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We searched PubMed, Embase, clinical trial registries, regulatory and device materials, abstracts, and manufacturer information when available.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion<\/jats:title>\n                    <jats:p>The current device innovations include postoperative pressure adjustability, stress\u2010responsive hydraulic systems, simplified pre\u2010filled or pre\u2010connected designs, electronic remote control, and nonhydraulic electromechanical compression. Several of the new and emerging devices have shown promising early data; however, most are limited to cohort data, early safety studies, or preclinical studies involving animal, cadaver, and ex vivo implementation. Importantly, direct comparisons with the AMS\u2010800 are limited.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>As these new devices continue to be created and introduced into clinical use, long\u2010term data will be needed to determine if these design advantages actually result in consistent improvements in continence outcomes, safety, durability, usability, and revision burden.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/nau.70400","type":"journal-article","created":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T06:35:53Z","timestamp":1785825353000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["New and Emerging Artificial Urinary Sphincters for Male Stress Urinary Incontinence: From Gold Standard to Next Generation"],"prefix":"10.1002","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-9730-3661","authenticated-orcid":false,"given":"Erin C.","family":"Schnell","sequence":"first","affiliation":[{"name":"Department of Urology Medical University of South Carolina Charleston SC USA"},{"name":"University of South Carolina School of Medicine Columbia SC USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3835-4053","authenticated-orcid":false,"given":"Connie N.","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Urology Medical University of South Carolina Charleston SC USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3950-8752","authenticated-orcid":false,"given":"Eric S.","family":"Rovner","sequence":"additional","affiliation":[{"name":"Department of Urology Medical University of South Carolina Charleston SC USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,8,3]]},"reference":[{"key":"e_1_2_12_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/JU.0000000000004796"},{"key":"e_1_2_12_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.euros.2025.02.004"},{"key":"e_1_2_12_4_1","doi-asserted-by":"publisher","DOI":"10.1111\/bju.13048"},{"key":"e_1_2_12_5_1","doi-asserted-by":"publisher","DOI":"10.1111\/aor.14606"},{"key":"e_1_2_12_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/iju.15083"},{"key":"e_1_2_12_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/aor.14535"},{"key":"e_1_2_12_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/nau.22989"},{"key":"e_1_2_12_9_1","doi-asserted-by":"publisher","DOI":"10.21037\/tau-22-858"},{"key":"e_1_2_12_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5347(17)59647-0"},{"key":"e_1_2_12_11_1","doi-asserted-by":"publisher","DOI":"10.21037\/tau-22-779"},{"key":"e_1_2_12_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00345-016-1787-5"},{"key":"e_1_2_12_13_1","doi-asserted-by":"publisher","DOI":"10.5173\/ceju.2019.1920"},{"key":"e_1_2_12_14_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41443-023-00748-8"},{"key":"e_1_2_12_15_1","unstructured":"Boston Scientific Corporation AMS 800TM Artificial Urinary Sphincter \u2010 Instructions for Use.2025 www.bostonscientific.com\/content\/dam\/elabeling\/uro-ph\/ams-800-ifu-male\/51266569-01A_AMS800_IFU_MALE_ML_s.pdf."},{"key":"e_1_2_12_16_1","unstructured":"S. A.Promedon VICTO Instructions for Use Document number: M\u201031\u201015\u20103255\/PSD\u201000000215(03) (2021) 40."},{"key":"e_1_2_12_17_1","doi-asserted-by":"publisher","DOI":"10.1259\/bjr\/56511504"},{"key":"e_1_2_12_18_1","unstructured":"Artificial Urinary Sphincter ZSI 375 Patient Selection Manual for Urologists Published online2019."},{"key":"e_1_2_12_19_1","unstructured":"Rigicon Inc. Product Information: ContiClassic\u00ae and ContiReflex\u00ae Artificial Urinary Sphincter Revised December 13 2019. Document no. TF\u201005.04."},{"key":"e_1_2_12_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.urology.2015.05.029"},{"key":"e_1_2_12_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11934-025-01286-0"},{"key":"e_1_2_12_22_1","doi-asserted-by":"publisher","DOI":"10.1111\/aor.14434"},{"key":"e_1_2_12_23_1","unstructured":"I.Rigicon \u201cContiClassic\u00ae \u201d Artificial Urinary Sphincter Instructions for Use Document identifier: CC\u2010IFU. Published online December 10 2023 15."},{"key":"e_1_2_12_24_1","doi-asserted-by":"publisher","DOI":"10.5489\/cuaj.4493"},{"issue":"4","key":"e_1_2_12_25_1","article-title":"MP46\u201020 Development of a Novel Artificial Urinary Sphincter (AUS): The Precision Medical Devices (PMD) Flow Control Device (FCD) for Management of Sphincteric Deficiency Using Bluetooth Technology","volume":"197","author":"Ahdoot M.","year":"2017","journal-title":"Journal of Urology"},{"key":"e_1_2_12_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.urology.2010.06.065"},{"key":"e_1_2_12_27_1","doi-asserted-by":"publisher","DOI":"10.1590\/S1677-5538.IBJU.2018.0128"},{"key":"e_1_2_12_28_1","doi-asserted-by":"publisher","DOI":"10.1002\/nau.23074"},{"key":"e_1_2_12_29_1","doi-asserted-by":"publisher","DOI":"10.1155\/2012\/439372"},{"key":"e_1_2_12_30_1","doi-asserted-by":"publisher","DOI":"10.1159\/000512722"},{"key":"e_1_2_12_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.urology.2011.11.065"},{"key":"e_1_2_12_32_1","unstructured":"Medicines and Healthcare products Regulatory Agency Suspension of Devices Manufactured by Silimed Published online September 23 2015."},{"key":"e_1_2_12_33_1","doi-asserted-by":"publisher","DOI":"10.21037\/tau-23-464"},{"key":"e_1_2_12_34_1","doi-asserted-by":"publisher","DOI":"10.1097\/JU.0000000000004945"},{"key":"e_1_2_12_35_1","unstructured":"ClinicalTrials.gov. Clinical Investigation to Assess a New Artificial Urinary Sphincter to Treat Urinary Incontinence in Men (SOPHIA) https:\/\/clinicaltrials.gov\/study\/NCT05547672."},{"key":"e_1_2_12_36_1","unstructured":"ClinicalTrials.gov. Clinical Investigation to Assess a New Artificial Urinary Sphincter to Treat Urinary Incontinence in Women https:\/\/clinicaltrials.gov\/study\/NCT05828979."},{"key":"e_1_2_12_37_1","unstructured":"ClinicalTrials.gov. A Study to Assess the Safety and Effectiveness of the UrOActive\u00ae Artificial Urinary sPHincter (AUS) (SOPHIA2) https:\/\/clinicaltrials.gov\/study\/NCT06968741."},{"issue":"6","key":"e_1_2_12_38_1","first-page":"8100","article-title":"The Artus Device: The First Feasibility Study in Human Cadavers","volume":"22","author":"Ludwig T. A.","year":"2015","journal-title":"Canadian Journal of Urology"},{"key":"e_1_2_12_39_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cont.2025.101970"},{"key":"e_1_2_12_40_1","article-title":"Universal Registration Document","volume":"2021","author":"Affluent Medical","year":"2022","journal-title":"Including the Annual Financial Report"},{"key":"e_1_2_12_41_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1464-410X.2012.11728.x"},{"key":"e_1_2_12_42_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.JU.0001009488.55564.85.16"},{"key":"e_1_2_12_43_1","unstructured":"M.Tarver \u201cFifty Years of the Medical Device Amendments: Building on a Strong Foundation to Advance Safe \u201d Effective and High\u2010 Quality Medical Devices (U.S. Food and Drug Administration 2026)."},{"key":"e_1_2_12_44_1","first-page":"1","article-title":"2017\/745 of the European Parliament and of the Council of 5 April 2017 on Medical Devices","volume":"117","author":"Regulation (EU)","year":"2017","journal-title":"Official Journal of the European Union"}],"container-title":["Neurourology and Urodynamics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/nau.70400","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/nau.70400","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/nau.70400","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T06:35:57Z","timestamp":1785825357000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/nau.70400"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,3]]},"references-count":43,"alternative-id":["10.1002\/nau.70400"],"URL":"https:\/\/doi.org\/10.1002\/nau.70400","archive":["Portico"],"relation":{},"ISSN":["0733-2467","1520-6777"],"issn-type":[{"value":"0733-2467","type":"print"},{"value":"1520-6777","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,3]]},"assertion":[{"value":"2026-06-23","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-24","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-08-03","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"nau.70400"}}