{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,3]],"date-time":"2025-12-03T07:35:12Z","timestamp":1764747312151,"version":"3.46.0"},"reference-count":46,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T00:00:00Z","timestamp":1760572800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["52293424","82327803","52277232"],"award-info":[{"award-number":["52293424","82327803","52277232"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100012226","name":"Fundamental Research Funds for the Central Universities","doi-asserted-by":"publisher","award":["2025ZFJH01"],"award-info":[{"award-number":["2025ZFJH01"]}],"id":[{"id":"10.13039\/501100012226","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004731","name":"Natural Science Foundation of Zhejiang Province","doi-asserted-by":"publisher","award":["LR23E070001"],"award-info":[{"award-number":["LR23E070001"]}],"id":[{"id":"10.13039\/501100004731","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["analyticalsciencejournals.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["NMR in Biomedicine"],"published-print":{"date-parts":[[2025,12]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>\n                    With the increasing adoption of ultra\u2010high\u2010field (UHF) systems, sodium (\n                    <jats:sup>23<\/jats:sup>\n                    Na) imaging is undergoing clinical translation. However, existing commercially available dual\u2010tuned coils, while demonstrating adequate sodium signal\u2010to\u2010noise ratio (SNR), fail to meet the requirements for high\u2010resolution proton (\n                    <jats:sup>1<\/jats:sup>\n                    H) structural imaging, resulting in suboptimal workflow efficiency during integrated multi\u2010nucleus examinations. In this work, we present a novel double\u2010layer\n                    <jats:sup>1<\/jats:sup>\n                    H\/\n                    <jats:sup>23<\/jats:sup>\n                    Na transceiver array with eight channels per nucleus for human brain MRI at 7T. The proposed array achieved 64% of the\n                    <jats:sup>1<\/jats:sup>\n                    H SNR of the 32\u2010channel receive array commonly used in clinical practice. By integrating dual\u2010nucleus imaging capabilities within a single platform, this design eliminates coil\u2010switching requirements and post\u2010acquisition registration, thereby streamlining clinical workflows and advancing sodium MRI translational feasibility.\n                  <\/jats:p>","DOI":"10.1002\/nbm.70162","type":"journal-article","created":{"date-parts":[[2025,10,16]],"date-time":"2025-10-16T07:39:12Z","timestamp":1760600352000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A Double\u2010Layer\n                    <sup>1<\/sup>\n                    H\/\n                    <sup>23<\/sup>\n                    Na Transceiver Array for Human Brain MRI at 7T"],"prefix":"10.1002","volume":"38","author":[{"given":"Feiyang","family":"Lou","sequence":"first","affiliation":[{"name":"The Interdisciplinary Institute of Neuroscience and Technology, School of Medcine Zhejiang University  Hangzhou China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Caohui","family":"Duan","sequence":"additional","affiliation":[{"name":"Department of Radiology Chinese PLA General Hospital  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhiyan","family":"Quan","sequence":"additional","affiliation":[{"name":"College of Biomedical Engineering and Instrument Science Zhejiang University  Hangzhou China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianxun","family":"Qu","sequence":"additional","affiliation":[{"name":"MR Research Collaboration Siemens Healthineers  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chenlu","family":"Guo","sequence":"additional","affiliation":[{"name":"College of Electrical Engineering Zhejiang University  Hangzhou China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Armin\u00a0M.","family":"Nagel","sequence":"additional","affiliation":[{"name":"Institute of Radiology University Hospital Erlangen, Friedrich\u2010Alexander\u2010Universit\u00e4t Erlangen\u2010N\u00fcrnberg (FAU)  Erlangen Germany"},{"name":"Division of Medical Physics in Radiology German Cancer Research Centre (DKFZ)  Heidelberg Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xin","family":"Lou","sequence":"additional","affiliation":[{"name":"Department of Radiology Chinese PLA General Hospital  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9197-1421","authenticated-orcid":false,"given":"Xiaotong","family":"Zhang","sequence":"additional","affiliation":[{"name":"The Interdisciplinary Institute of Neuroscience and Technology, School of Medcine Zhejiang University  Hangzhou China"},{"name":"Department of Radiology Chinese PLA General Hospital  Beijing China"},{"name":"College of Electrical Engineering Zhejiang University  Hangzhou China"},{"name":"Second Affiliated Hospital at the School of Medicine Zhejiang University  Hangzhou China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,10,16]]},"reference":[{"key":"e_1_2_11_2_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.24168"},{"key":"e_1_2_11_3_1","first-page":"449","volume-title":"Advances in Magnetic Resonance Technology and Applications","author":"Zaaraoui W.","year":"2023"},{"key":"e_1_2_11_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pnmrs.2023.04.002"},{"key":"e_1_2_11_5_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.27103"},{"key":"e_1_2_11_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24192"},{"key":"e_1_2_11_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0b013e31821ae918"},{"key":"e_1_2_11_8_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2020.07.003"},{"key":"e_1_2_11_9_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.27880"},{"key":"e_1_2_11_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24432"},{"key":"e_1_2_11_11_1","first-page":"4880","volume-title":"Design and Application of a Nested Multi\u2010Channel Sodium Proton Knee Array at 3T","author":"Brown R.","year":"2014"},{"key":"e_1_2_11_12_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.3867"},{"key":"e_1_2_11_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25572"},{"key":"e_1_2_11_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.4806"},{"key":"e_1_2_11_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.25666"},{"key":"e_1_2_11_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.28073"},{"key":"e_1_2_11_17_1","first-page":"2159","article-title":"A Nested Dual Frequency Birdcage\/Stripline Coil for Sodium\/Proton Brain Imaging at 7T","volume":"18","author":"Wiggins G. C.","year":"2010","journal-title":"Proceedings of the International Society for Magnetic Resonance in Medicine"},{"key":"e_1_2_11_18_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.4608"},{"key":"e_1_2_11_19_1","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/55\/2\/N01"},{"key":"e_1_2_11_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2009.06.005"},{"key":"e_1_2_11_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910160203"},{"key":"e_1_2_11_22_1","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2019.2933733"},{"key":"e_1_2_11_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24931"},{"key":"e_1_2_11_24_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20713"},{"key":"e_1_2_11_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22157"},{"key":"e_1_2_11_26_1","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000981"},{"key":"e_1_2_11_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.zemedi.2019.10.004"},{"key":"e_1_2_11_28_1","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S"},{"key":"e_1_2_11_29_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.28176"},{"key":"e_1_2_11_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.4577"},{"key":"e_1_2_11_31_1","unstructured":"M. A.Erturk R. L.Lagore E. J.Auerbach et\u00a0al. Design and Implementation of a Combined Sodium\u2010Loop Proton\u2010Dipole Transceiver Array for Body Imaging at 10.5 Tesla. In:Proceeding 27th Annual Meeting of the International Society of Magnetic Resonance in Medicine (ISMRM). Vol 431.;2019."},{"key":"e_1_2_11_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.30426"},{"key":"e_1_2_11_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.27953"},{"key":"e_1_2_11_34_1","unstructured":"X.Li G.Zhang W.Zhu X.Zhang X. H.Zhu andW.Chen.Double Tuned and Double Matched Large\u2010Size Loop Coil (DODO) Design and Evaluation for 17O MRSI and 1H MRI Application at 7T. In:Proceedings of the International Society for Magnetic Resonance in Medicine\u2026 Scientific Meeting and Exhibition. International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition. Vol 31.;2023:5077."},{"key":"e_1_2_11_35_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2024.110268"},{"key":"e_1_2_11_36_1","unstructured":"F.Wiesinger N.De Zanche andK. P.Pruessmann.Approaching Ultimate SNR With Finite Coil Arrays. In:Proceedings of the 13th Annual Meeting of ISMRM. Vol 672.;2005."},{"key":"e_1_2_11_37_1","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2022.3209678"},{"key":"e_1_2_11_38_1","doi-asserted-by":"publisher","DOI":"10.1109\/TIM.2025.3547125"},{"key":"e_1_2_11_39_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.28428"},{"key":"e_1_2_11_40_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24417"},{"key":"e_1_2_11_41_1","doi-asserted-by":"publisher","DOI":"10.1093\/brain\/awv386"},{"key":"e_1_2_11_42_1","doi-asserted-by":"publisher","DOI":"10.1038\/srep31269"},{"key":"e_1_2_11_43_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.27832"},{"key":"e_1_2_11_44_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.3292"},{"key":"e_1_2_11_45_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.20868"},{"key":"e_1_2_11_46_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2015.03.025"},{"key":"e_1_2_11_47_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.4959"}],"container-title":["NMR in Biomedicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/nbm.70162","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,12,3]],"date-time":"2025-12-03T07:29:39Z","timestamp":1764746979000},"score":1,"resource":{"primary":{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/10.1002\/nbm.70162"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,16]]},"references-count":46,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2025,12]]}},"alternative-id":["10.1002\/nbm.70162"],"URL":"https:\/\/doi.org\/10.1002\/nbm.70162","archive":["Portico"],"relation":{},"ISSN":["0952-3480","1099-1492"],"issn-type":[{"type":"print","value":"0952-3480"},{"type":"electronic","value":"1099-1492"}],"subject":[],"published":{"date-parts":[[2025,10,16]]},"assertion":[{"value":"2025-04-16","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-30","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-16","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70162"}}