{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T08:48:24Z","timestamp":1792054104768,"version":"4.4.0"},"reference-count":48,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T00:00:00Z","timestamp":1790294400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T00:00:00Z","timestamp":1790294400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["R01 EB031078"],"award-info":[{"award-number":["R01 EB031078"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["S10 OD030389"],"award-info":[{"award-number":["S10 OD030389"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["analyticalsciencejournals.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["NMR in Biomedicine"],"published-print":{"date-parts":[[2026,11]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>This work develops and validates a practical method for quantifying the transmit\u2010power threshold at which passive detuning of inductively coupled wireless resonators becomes reliable in MRI. All experiments were performed using phantoms. A near\/far spatial signal ratio is computed from a series of gradient\u2010echo (GRE) images acquired at different nominal flip angles. This ratio reveals ineffective detuning as a characteristic L\u2010shaped curve whose inflection point marks the detuning threshold. The method was validated experimentally with wireless resonators incorporating different numbers of crossed diode pairs, at multiple static field strengths (3 and 7T), and with different scanner vendors. At 3T, the method produced consistent  thresholds across Philips and GE scanners despite their different flip\u2010angle thresholds. The proposed method provides a practical, straightforward tool for acceptance testing and quality assurance of wireless resonator safety in both clinical and research MRI settings.<\/jats:p>","DOI":"10.1002\/nbm.70408","type":"journal-article","created":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T08:33:50Z","timestamp":1790325230000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Quantifying the Transmit\u2010Power Threshold for Reliable Passive Detuning of Inductively Coupled Wireless Resonators in MRI: A Phantom Study"],"prefix":"10.1002","volume":"39","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2763-2561","authenticated-orcid":false,"given":"Ming","family":"Lu","sequence":"first","affiliation":[{"name":"Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center  Nashville Tennessee USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0369-6301","authenticated-orcid":false,"given":"Xiaoyu","family":"Jiang","sequence":"additional","affiliation":[{"name":"Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center  Nashville Tennessee USA"},{"name":"Department of Radiology and Radiological Sciences Vanderbilt University Medical Center  Nashville Tennessee USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0830-9232","authenticated-orcid":false,"given":"Yajun","family":"Ma","sequence":"additional","affiliation":[{"name":"Department of Radiology University of California  San Diego California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yurui","family":"Qian","sequence":"additional","affiliation":[{"name":"Department of Radiology and Biomedical Imaging University of California  San Francisco California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2270-276X","authenticated-orcid":false,"given":"Congyu","family":"Liao","sequence":"additional","affiliation":[{"name":"Department of Radiology and Biomedical Imaging University of California  San Francisco California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2841-4243","authenticated-orcid":false,"given":"Yang","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Radiology and Biomedical Imaging University of California  San Francisco California USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9480-0900","authenticated-orcid":false,"given":"John C.","family":"Gore","sequence":"additional","affiliation":[{"name":"Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center  Nashville Tennessee USA"},{"name":"Department of Radiology and Radiological Sciences Vanderbilt University Medical Center  Nashville Tennessee USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4232-3241","authenticated-orcid":false,"given":"Xinqiang","family":"Yan","sequence":"additional","affiliation":[{"name":"Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center  Nashville Tennessee USA"},{"name":"Department of Radiology and Radiological Sciences Vanderbilt University Medical Center  Nashville Tennessee USA"},{"name":"Department of Electrical and Computer Engineering Vanderbilt University  Nashville Tennessee USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2026,9,25]]},"reference":[{"key":"e_1_2_12_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-2364(86)90326-4"},{"key":"e_1_2_12_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/0022-2364(86)90111-3"},{"key":"e_1_2_12_4_1","unstructured":"J.Tanttu \u201cNMR Coil Arrangement \u201d (1987) US Patent 4 680 549."},{"key":"e_1_2_12_5_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910170128"},{"key":"e_1_2_12_6_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910290423"},{"key":"e_1_2_12_7_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910300514"},{"key":"e_1_2_12_8_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.1576227"},{"key":"e_1_2_12_9_1","doi-asserted-by":"crossref","unstructured":"T.Sahara S.Hashimoto H.Tsutsui et\u00a0al. \u201cDevelopment of Inductively Coupled Wireless Radio Frequency Coil for Magnetic Resonance Scanners \u201d inInaugural IEEE\u2010IES Digital Ecosystems and Technologies Conference (2007):464\u2013467.","DOI":"10.1109\/DEST.2007.372017"},{"key":"e_1_2_12_10_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2008.2006523"},{"key":"e_1_2_12_11_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22864"},{"key":"e_1_2_12_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2022.107209"},{"key":"e_1_2_12_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/admt.202301053"},{"key":"e_1_2_12_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.4818"},{"key":"e_1_2_12_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.5068"},{"key":"e_1_2_12_16_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2017.02.003"},{"key":"e_1_2_12_17_1","doi-asserted-by":"publisher","DOI":"10.21037\/qims.2017.02.10"},{"key":"e_1_2_12_18_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-02533-3"},{"key":"e_1_2_12_19_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.29062"},{"key":"e_1_2_12_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2024.107650"},{"key":"e_1_2_12_21_1","doi-asserted-by":"publisher","DOI":"10.1002\/nbm.5224"},{"key":"e_1_2_12_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2024.04.016"},{"key":"e_1_2_12_23_1","doi-asserted-by":"publisher","DOI":"10.1002\/mp.17731"},{"key":"e_1_2_12_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2025.110497"},{"key":"e_1_2_12_25_1","doi-asserted-by":"publisher","DOI":"10.1002\/advs.202503481"},{"key":"e_1_2_12_26_1","doi-asserted-by":"publisher","DOI":"10.1109\/TAP.2025.3628955"},{"key":"e_1_2_12_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.mri.2025.110330"},{"key":"e_1_2_12_28_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.70170"},{"key":"e_1_2_12_29_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.70326"},{"key":"e_1_2_12_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910160203"},{"key":"e_1_2_12_31_1","doi-asserted-by":"publisher","DOI":"10.1006\/jmra.1993.1133"},{"key":"e_1_2_12_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.22357"},{"key":"e_1_2_12_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.21120"},{"key":"e_1_2_12_34_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.24158"},{"key":"e_1_2_12_35_1","unstructured":"M.Lu C.Liao Y.Qian P.Li Y.Yang andX.Yan \u201cHow Many Tx Power or Flip Angles are Required to Passively Detuning the Wireless Resonator? \u201d inProceedings of the ISMRM Annual Meeting (2026). Abstract #00889."},{"key":"e_1_2_12_36_1","doi-asserted-by":"publisher","DOI":"10.1063\/1.1719961"},{"key":"e_1_2_12_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmr.2025.107955"},{"key":"e_1_2_12_38_1","doi-asserted-by":"publisher","DOI":"10.1063\/5.0304790"},{"key":"e_1_2_12_39_1","unstructured":"X.Yang T.Zheng Y.Wu andM.Finnerty \u201cCoaxial Cable Magnetic Resonance Image (MRI) Coil \u201d (2017) US Patent 9 678 180."},{"key":"e_1_2_12_40_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41551-018-0233-y"},{"key":"e_1_2_12_41_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2021.3051390"},{"key":"e_1_2_12_42_1","unstructured":"Microsemi Corporation \u201cUMX9989AP: Dual Ultra Low Magnetic Moment Fast Diodes for MRI Applications \u201d Datasheet. Available at:https:\/\/ww1.microchip.com\/downloads\/aemDocuments\/documents\/RFDS\/ProductDocuments\/DataSheets\/umx9989ap_datasheet.pdf."},{"key":"e_1_2_12_43_1","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910340618"},{"key":"e_1_2_12_44_1","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.28408"},{"key":"e_1_2_12_45_1","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2014.2377792"},{"key":"e_1_2_12_46_1","doi-asserted-by":"publisher","DOI":"10.1021\/acsami.7b06949"},{"key":"e_1_2_12_47_1","doi-asserted-by":"publisher","DOI":"10.1038\/s42005-019-0135-7"},{"key":"e_1_2_12_48_1","doi-asserted-by":"publisher","DOI":"10.1038\/s42254-021-00394-3"},{"key":"e_1_2_12_49_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10334-022-01007-5"}],"container-title":["NMR in Biomedicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/nbm.70408","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/nbm.70408","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/nbm.70408","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T08:21:28Z","timestamp":1792052488000},"score":1,"resource":{"primary":{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/10.1002\/nbm.70408"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,25]]},"references-count":48,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2026,11]]}},"alternative-id":["10.1002\/nbm.70408"],"URL":"https:\/\/doi.org\/10.1002\/nbm.70408","archive":["Portico"],"relation":{},"ISSN":["0952-3480","1099-1492"],"issn-type":[{"value":"0952-3480","type":"print"},{"value":"1099-1492","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,25]]},"assertion":[{"value":"2026-06-10","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-09","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-09-25","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70408"}}