{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T01:50:52Z","timestamp":1774921852211,"version":"3.50.1"},"reference-count":20,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2005,11,11]],"date-time":"2005-11-11T00:00:00Z","timestamp":1131667200000},"content-version":"vor","delay-in-days":5428,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Pediatric Pulmonology"],"published-print":{"date-parts":[[1991,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Pulse oximetry is noninvasive, fast, and simple, making it a very popular way of assessing oxygenation in pediatric patients. However, there are few studies that establish the accuracy of this technology over a wide range of oxygen saturations in children. This study, done in 47 children aged from 1 day to 16 years with congenital heart disease and undergoing cardiac catheterization, compared the direct measurement of arterial oxygen saturation to values from pulse oximetry. Oxygen saturation was measured by an IL\u2010282 Co\u2010oximeter, which also measured carboxyhemoglobin and methemoglobin, and was compared to values obtained from both a Biox III and Nellcor N100. Both pulse oximeters gave values that closely correlated with the actual saturation (r = 0.91 and 0.93, respectively) with standard errors of the estimate of 4.1 and 3.2%, respectively. For both devices, the error increased with decreasing saturations, being progressively larger below a saturation of 80%. The difference between the actual saturation and that measured by pulse oximetry bore no relationship to the presence of carboxyhemoglobin, methemoglobin, fetal hemoglobin, bilirubin, cardiac index, or age of the patient. In conclusion, pulse oximetry, while a very useful technology in pediatrics, must be interpreted with some caution in children with severe cyanosis. Pediatr Pulmonol 1991; 10:132\u2013135.<\/jats:p>","DOI":"10.1002\/ppul.1950100216","type":"journal-article","created":{"date-parts":[[2007,3,6]],"date-time":"2007-03-06T15:39:32Z","timestamp":1173195572000},"page":"132-135","source":"Crossref","is-referenced-by-count":18,"title":["Pulse oximetry versus measured arterial oxygen saturation: A comparison of the Nellcor N100 and the Biox III"],"prefix":"10.1002","volume":"10","author":[{"given":"Patrick","family":"Lebecque","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Polycarpe","family":"Shango","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maddy","family":"Stijns","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andr\u00e9","family":"Vliers","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Allan L.","family":"Coates","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2005,11,11]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-198710000-00017"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01617877"},{"key":"e_1_2_1_4_2","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1542\/peds.78.5.844","article-title":"Pulse oximetry advantages in infants with bronchopulmonary dysplasia","volume":"78","author":"Solimano AJ","year":"1986","journal-title":"Pediatrics."},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0021-9673(01)89053-1"},{"key":"e_1_2_1_6_2","first-page":"349","article-title":"Infrared heat lamps interfere with pulse oximeters","volume":"59","author":"Brooks TD","year":"1984","journal-title":"Anesthesiology."},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_2_1_8_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1542\/peds.79.1.1","article-title":"Report of the Second Task Force on Blood Pressure Control in Children\u20141987","volume":"79","year":"1987","journal-title":"Pediatrics."},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.91.3.333"},{"key":"e_1_2_1_10_2","doi-asserted-by":"crossref","first-page":"1555","DOI":"10.1093\/clinchem\/29.8.1555","article-title":"Correction factors for hemoglobin derivatives in fetal blood, as measured with the IL 282\u2010Co\u2010oximeter","volume":"29","author":"Cornelissen PJH","year":"1983","journal-title":"Clin Chem."},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-198711000-00015"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF02851170"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-198611000-00010"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3476(88)80326-3"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1002\/ppul.1950060310"},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3476(86)80298-0"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-3476(85)80507-2"},{"key":"e_1_2_1_18_2","first-page":"343","article-title":"Use of pulse oximetry in neonatal anesthesia","volume":"7","author":"Miyasaka K","year":"1987","journal-title":"J Perinatol."},{"key":"e_1_2_1_19_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-198411000-00002"},{"key":"e_1_2_1_20_2","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1542\/peds.79.4.524","article-title":"Pulse oximetry: An alternative method for the assessment of oxygenation in newborn infants","volume":"79","author":"Jennis MS","year":"1987","journal-title":"Pediatrics."},{"key":"e_1_2_1_21_2","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1542\/peds.79.4.612","article-title":"Pulse oximetry in very low birth weight infants with acute and chronic disease","volume":"79","author":"Ramanathan R","year":"1987","journal-title":"Pediatrics."}],"container-title":["Pediatric Pulmonology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fppul.1950100216","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ppul.1950100216","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,23]],"date-time":"2023-10-23T18:24:53Z","timestamp":1698085493000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/ppul.1950100216"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1991,1]]},"references-count":20,"journal-issue":{"issue":"2","published-print":{"date-parts":[[1991,1]]}},"alternative-id":["10.1002\/ppul.1950100216"],"URL":"https:\/\/doi.org\/10.1002\/ppul.1950100216","archive":["Portico"],"relation":{},"ISSN":["8755-6863","1099-0496"],"issn-type":[{"value":"8755-6863","type":"print"},{"value":"1099-0496","type":"electronic"}],"subject":[],"published":{"date-parts":[[1991,1]]}}}