{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,15]],"date-time":"2025-08-15T01:58:51Z","timestamp":1755223131797,"version":"3.43.0"},"reference-count":25,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2025,6,19]],"date-time":"2025-06-19T00:00:00Z","timestamp":1750291200000},"content-version":"vor","delay-in-days":18,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100021171","name":"Basic and Applied Basic Research Foundation of Guangdong Province","doi-asserted-by":"publisher","award":["2020A1515110335"],"award-info":[{"award-number":["2020A1515110335"]}],"id":[{"id":"10.13039\/501100021171","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Precision Radiation Oncology"],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>CyberKnife, an established noninvasive stereotactic radiotherapy technology, has been extensively utilized to treat various malignancies because of its high precision and conformal dose delivery. The success of CyberKnife treatment is crucially dependent on optimal fiducial marker placement. This study introduces a\u00a0novel\u00a0fiducial marker placement planning algorithm\u00a0tailored\u00a0for superficial tumors, which are located 20\u201350 mm beneath the epidermis.\u00a0A retrospective analysis was performed\u00a0on the data collected from three patients with thymus, breast, and submandibular gland tumors. This algorithm generated potential implantation sites by constructing and optimizing a B\u2010spline surface around the tumor. Candidate points were filtered using multi\u2010criteria constraints: (1) a minimum of 18\u2010mm inter\u2010marker distance, (2) angular separation &gt;30\u00b0, and (3) nonoverlapping visibility in 45\u00b0 oblique digital reconstructed radiographs. To enhance the computational efficiency, a kd\u2010tree spatial indexing structure was integrated with graph theory, specifically the Bron\u2013Kerbosch algorithm for maximal clique detection. The proposed method achieved a time complexity of , demonstrating a significant improvement\u00a0over the brute\u2010force  approach. The experimental results showed that our algorithm could efficiently plan fiducial marker placement, thereby simplifying the planning process and providing valuable technical support for CyberKnife treatments.<\/jats:p>","DOI":"10.1002\/pro6.70017","type":"journal-article","created":{"date-parts":[[2025,6,19]],"date-time":"2025-06-19T22:53:52Z","timestamp":1750373632000},"page":"87-95","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Optimized fiducial marker placement using B\u2010spline surface modeling and graph theory for Cyberknife stereotactic body radiotherapy for superficial tumors"],"prefix":"10.1002","volume":"9","author":[{"given":"Jing","family":"Huang","sequence":"first","affiliation":[{"name":"School of Computer Science and Artificial Intelligence Wuhan University of Technology  Wuhan China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xianlong","family":"Xiong","sequence":"additional","affiliation":[{"name":"School of Computer Science and Artificial Intelligence Wuhan University of Technology  Wuhan China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cheng","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Radiation and Medical Oncology Zhongnan Hospital of Wuhan University  Wuhan Hubei China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuhan","family":"Li","sequence":"additional","affiliation":[{"name":"School of Computer Science and Artificial Intelligence Wuhan University of Technology  Wuhan China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruijie","family":"Wang","sequence":"additional","affiliation":[{"name":"School of Computer Science and Artificial Intelligence Wuhan University of Technology  Wuhan China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhitao","family":"Dai","sequence":"additional","affiliation":[{"name":"National Cancer Center\/National Clinical Research Center for Cancer\/Cancer Hospital &amp; Shenzhen Hospital Chinese Academy, of Medical Sciences and Peking Union Medical College  Shenzhen China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2025,6,19]]},"reference":[{"issue":"6","key":"e_1_2_12_2_1","first-page":"676","article-title":"Stereotactic body radiation therapy (SBRT) in pancreatic cancer: is it ready for prime time?","volume":"9","author":"Chang BW","year":"2008","journal-title":"JOP"},{"key":"e_1_2_12_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijrobp.2009.01.042"},{"issue":"1","key":"e_1_2_12_4_1","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1159\/000099863","article-title":"The Cyberknife: a frameless robotic system for radiosurgery","volume":"69","author":"JR Adler","year":"1997","journal-title":"Stereotact Funct Neurosurg"},{"key":"e_1_2_12_5_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-009-9748-7"},{"key":"e_1_2_12_6_1","doi-asserted-by":"publisher","DOI":"10.14309\/00000434-200910003-00677"},{"key":"e_1_2_12_7_1","doi-asserted-by":"publisher","DOI":"10.1055\/a-1068-9128"},{"key":"e_1_2_12_8_1","doi-asserted-by":"publisher","DOI":"10.3857\/roj.2020.00472"},{"key":"e_1_2_12_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.gie.2018.04.1957"},{"key":"e_1_2_12_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvir.2014.01.004"},{"key":"e_1_2_12_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.urology.2007.10.011"},{"key":"e_1_2_12_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-8140(12)71614-6"},{"key":"e_1_2_12_13_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3612018"},{"key":"e_1_2_12_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/resp.14006"},{"key":"e_1_2_12_15_1","doi-asserted-by":"publisher","DOI":"10.1510\/icvts.2009.227348"},{"key":"e_1_2_12_16_1","doi-asserted-by":"publisher","DOI":"10.1118\/1.3218845"},{"key":"e_1_2_12_17_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13014-019-1401-2"},{"key":"e_1_2_12_18_1","doi-asserted-by":"publisher","DOI":"10.3389\/fonc.2022.1021119"},{"issue":"10","key":"e_1_2_12_19_1","article-title":"Evaluation of CyberKnife\u00ae Fiducial Tracking Limitations to Assist Targeting Accuracy: A Phantom Study with Fiducial Displacement","volume":"10","author":"Goldsmith C","year":"2018","journal-title":"Cureus"},{"key":"e_1_2_12_20_1","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.112.660548"},{"key":"e_1_2_12_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.pnmrs.2012.03.001"},{"key":"e_1_2_12_22_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4612-6333-3"},{"key":"e_1_2_12_23_1","doi-asserted-by":"publisher","DOI":"10.1137\/14095354X"},{"key":"e_1_2_12_24_1","doi-asserted-by":"publisher","DOI":"10.1109\/ICSMC.2004.1401205"},{"key":"e_1_2_12_25_1","doi-asserted-by":"publisher","DOI":"10.1090\/S0025-5718-1994-1250775-2"},{"key":"e_1_2_12_26_1","doi-asserted-by":"publisher","DOI":"10.1137\/S003614299630434"}],"container-title":["Precision Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/pro6.70017","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,11]],"date-time":"2025-08-11T12:30:52Z","timestamp":1754915452000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/pro6.70017"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6]]},"references-count":25,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,6]]}},"alternative-id":["10.1002\/pro6.70017"],"URL":"https:\/\/doi.org\/10.1002\/pro6.70017","archive":["Portico"],"relation":{},"ISSN":["2398-7324","2398-7324"],"issn-type":[{"type":"print","value":"2398-7324"},{"type":"electronic","value":"2398-7324"}],"subject":[],"published":{"date-parts":[[2025,6]]},"assertion":[{"value":"2025-02-03","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-07","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-06-19","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}