{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T18:44:37Z","timestamp":1787856277003,"version":"build-2784847793"},"reference-count":29,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2025,2,26]],"date-time":"2025-02-26T00:00:00Z","timestamp":1740528000000},"content-version":"vor","delay-in-days":56,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Pulm. circ."],"published-print":{"date-parts":[[2025,1]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:p>Direct Fick (DF) and bolus thermodilution (TD) are endorsed by pulmonary hypertension (PH) guidelines to measure cardiac output. In contemporary practice, agreement between methods is unknown, as are the diagnostic consequences of disagreement. We sought to evaluate the frequency and degree of disagreements between cardiac output measurement techniques and assess their impact on the hemodynamic assessment of PH. This was a single\u2010center study that included 182 patients who had cardiac output concurrently measured by DF and TD. Oxygen consumption was measured by indirect calorimetry. Agreement between DF and bolus TD cardiac output was assessed using Bland\u2013Altman analysis. The median DF and TD cardiac outputs were 5.42\u2009L\/min (interquartile range [IQR] 3.90\u20137.41) and 4.10\u2009L\/min (IQR 3.47\u20135.10), respectively. Significant disagreement was observed with DF yielding higher cardiac output results than TD. Mean error was proportional to cardiac output (\u22123.75% at 3\u2009L\/min to +44.5% at 7\u2009L\/min), and limits of agreement were wide. Disagreement was increased by 19.2% in the presence of least moderate tricuspid regurgitation and by 16.0% in patients with atrial fibrillation. Among 152 patients with PH, hemodynamic classification discordance occurred in 18 (11.8%) patients. Disagreement between DF and TD was observed, which resulted in a discrepant hemodynamic classification in approximately 12% of patients. These techniques should, therefore, not be used interchangeably for serial surveillance, and without a clinical gold standard, a rationale exists for utilizing both methods concurrently in certain clinical situations.<\/jats:p>","DOI":"10.1002\/pul2.70053","type":"journal-article","created":{"date-parts":[[2025,3,10]],"date-time":"2025-03-10T22:53:23Z","timestamp":1741647203000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Differences in Direct Fick and Thermodilution Measurements of Cardiac Output: Impact on Pulmonary Hypertension Classification"],"prefix":"10.1002","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8900-7529","authenticated-orcid":false,"given":"Garry W.","family":"Hamilton","sequence":"first","affiliation":[{"name":"Department of Cardiology Austin Health Heidelberg Australia"},{"name":"Department of Medicine The University of Melbourne Parkville Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luke R.","family":"Fletcher","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia Austin Health Heidelberg Australia"},{"name":"Department of Critical Care The University of Melbourne Parkville Australia"},{"name":"Data Analytics Research and Evaluation Centre (DARE) Austin Health and The University of Melbourne Heidelberg Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William","family":"Harley","sequence":"additional","affiliation":[{"name":"Department of Cardiology Austin Health Heidelberg Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Azzopardi","sequence":"additional","affiliation":[{"name":"Department of Cardiology Austin Health Heidelberg Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2120-0792","authenticated-orcid":false,"given":"R. Kimberly","family":"Chan","sequence":"additional","affiliation":[{"name":"Department of Cardiology Austin Health Heidelberg Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jordan","family":"Fulcher","sequence":"additional","affiliation":[{"name":"Department of Cardiology Austin Health Heidelberg Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lachlan F.","family":"Miles","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia Austin Health Heidelberg Australia"},{"name":"Department of Critical Care The University of Melbourne Parkville Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omar","family":"Farouque","sequence":"additional","affiliation":[{"name":"Department of Cardiology Austin Health Heidelberg Australia"},{"name":"Department of Medicine The University of Melbourne Parkville Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark C. G.","family":"Horrigan","sequence":"additional","affiliation":[{"name":"Department of Cardiology Austin Health Heidelberg Australia"},{"name":"Department of Medicine The University of Melbourne Parkville Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2025,2,26]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehac237"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1159\/000517084"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.bja.2021.01.005"},{"issue":"5","key":"e_1_2_10_5_1","doi-asserted-by":"crossref","first-page":"e72","DOI":"10.1161\/CIR.0000000000000923","article-title":"2020 ACC\/AHA Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines","volume":"143","author":"Otto C. M.","year":"2021","journal-title":"Circulation"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(71)90436-X"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/CRD.0000000000000223"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.eurheartj.a060976"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1093\/cvr\/4.1.23"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1002\/clc.4960050803"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1378\/chest.122.3.990"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s001340050443"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm.160.2.9811062"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1002\/pul2.12128"},{"key":"e_1_2_10_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.amjcard.2022.04.026"},{"key":"e_1_2_10_16_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1527-5299.2004.03406.x"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF01699240"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9149(87)90829-0"},{"issue":"4","key":"e_1_2_10_19_1","first-page":"281","article-title":"Cardiac Output Measurement: A Comparison of Direct Fick, Dye Dilution and Thermodilution Methods in Stable and Acutely Ill Patients","volume":"68","author":"Venkataraman K.","year":"1976","journal-title":"Journal of the National Medical Association"},{"key":"e_1_2_10_20_1","doi-asserted-by":"publisher","DOI":"10.3389\/fped.2018.00257"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF01618114"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2010.05.010"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2017.02.009"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.echo.2017.01.007"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9343(89)90339-2"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.1155\/2012\/261793"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.2005.00613.x"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1953.5.10.635"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12020410"}],"container-title":["Pulmonary Circulation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/pul2.70053","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,11]],"date-time":"2025-04-11T10:33:48Z","timestamp":1744367628000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/pul2.70053"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,1]]}},"alternative-id":["10.1002\/pul2.70053"],"URL":"https:\/\/doi.org\/10.1002\/pul2.70053","archive":["Portico"],"relation":{},"ISSN":["2045-8940","2045-8940"],"issn-type":[{"value":"2045-8940","type":"print"},{"value":"2045-8940","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1]]},"assertion":[{"value":"2024-08-18","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-01-31","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-02-26","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e70053"}}