{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T13:18:47Z","timestamp":1762175927729,"version":"build-2065373602"},"reference-count":18,"publisher":"Wiley","issue":"11","license":[{"start":{"date-parts":[[2006,4,24]],"date-time":"2006-04-24T00:00:00Z","timestamp":1145836800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Rapid Comm Mass Spectrometry"],"published-print":{"date-parts":[[2006,6,15]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Elemental analyzer\/continuous flow isotope ratio mass spectrometry (EA\/CF\u2010IRMS) has become a standard procedure for the determination of\n                    <jats:italic>\u03b4<\/jats:italic>\n                    <jats:sup>34<\/jats:sup>\n                    S values. Common procedures are, however, frequently less than satisfactory for organic as well as for mineral samples with very low concentrations of sulfur (&lt;2000 ppm). Here we present a method which employs cold trapping of SO\n                    <jats:sub>2<\/jats:sub>\n                    to adjust the gas concentration for subsequent isotope signature determination. Analytical accuracy is comparable with common EA\/CF\u2010IRMS analysis without trapping, showing a precision of better than \u00b10.4\u2030 in\n                    <jats:italic>\u03b4<\/jats:italic>\n                    <jats:sup>34<\/jats:sup>\n                    S (1 SD). The virtual absence of memory effects was established by analyzing adjacent samples exhibiting a large difference in\n                    <jats:italic>\u03b4<\/jats:italic>\n                    <jats:sup>34<\/jats:sup>\n                    S and by prolonged freezing of the carrier gas, yielding virtually no S concentration peak. The method was tested using less than 15% (6\u2009\u00b5g) of the S required for a conventional isotope analysis at comparable signal intensity. Even smaller samples can be analyzed with high precision. This facilitates the on\u2010line\n                    <jats:italic>\u03b4<\/jats:italic>\n                    <jats:sup>34<\/jats:sup>\n                    S determination in small biological and mineral samples, minimizing matrix effects in various materials including sandstone, soil, and plant samples. Copyright \u00a9 2006 John Wiley &amp; Sons, Ltd.\n                  <\/jats:p>","DOI":"10.1002\/rcm.2488","type":"journal-article","created":{"date-parts":[[2006,4,24]],"date-time":"2006-04-24T12:22:21Z","timestamp":1145881341000},"page":"1679-1682","source":"Crossref","is-referenced-by-count":8,"title":["Signal improvement in elemental analyzer\/continuous flow isotope ratio mass spectrometry for samples with low sulfur contents using a pre\u2010concentration technique for on\u2010line concentration adjustment"],"prefix":"10.1002","volume":"20","author":[{"given":"Florian","family":"Fritzsche","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marion","family":"Tichomirowa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2006,4,24]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF00025048"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.1080\/10256019608036311"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-3040.1999.00445.x"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0038-0717(02)00086-X"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00442-002-1153-8"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1080\/10256010310001621119"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1080\/03067310410001679994"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1021\/ac00257a046"},{"key":"e_1_2_6_10_2","doi-asserted-by":"publisher","DOI":"10.1080\/10256010208033325"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1021\/ac00090a005"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1002\/rcm.2213"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1021\/ac000550f"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1080\/10256010108033281"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0009-2541(02)00162-6"},{"key":"e_1_2_6_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.chemgeo.2003.11.008"},{"key":"e_1_2_6_17_2","first-page":"1","volume-title":"Mass Spectrometry of Soils","author":"Barrie A","year":"1996"},{"volume-title":"Reference Materials Catalogue 2004\u20132005","year":"2004","author":"IAEA Analytical Quality Control Services","key":"e_1_2_6_18_2"},{"key":"e_1_2_6_19_2","doi-asserted-by":"publisher","DOI":"10.1002\/rcm.1939"}],"container-title":["Rapid Communications in Mass Spectrometry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Frcm.2488","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/rcm.2488","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,26]],"date-time":"2025-10-26T11:21:03Z","timestamp":1761477663000},"score":1,"resource":{"primary":{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/10.1002\/rcm.2488"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,4,24]]},"references-count":18,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2006,6,15]]}},"alternative-id":["10.1002\/rcm.2488"],"URL":"https:\/\/doi.org\/10.1002\/rcm.2488","archive":["Portico"],"relation":{},"ISSN":["0951-4198","1097-0231"],"issn-type":[{"type":"print","value":"0951-4198"},{"type":"electronic","value":"1097-0231"}],"subject":[],"published":{"date-parts":[[2006,4,24]]}}}