{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T04:03:12Z","timestamp":1791259392069,"version":"4.1.0"},"reference-count":35,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2014,12,11]],"date-time":"2014-12-11T00:00:00Z","timestamp":1418256000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Rapid Comm Mass Spectrometry"],"published-print":{"date-parts":[[2015,1,30]]},"abstract":"<jats:sec>\n                    <jats:title>RATIONALE<\/jats:title>\n                    <jats:p>This paper highlights the simplicity of interfacing an Atmospheric Solid Analysis Probe (ASAP) to a Linear Ion Trap Mass Spectrometer and shows that this technique can be used for the rapid generation of high\u2010quality data from a range of sample types with minimal or no sample preparation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>For a solid sample or surface deposit, the process entails rubbing a capillary melting tube a few times on the sample to transfer material to the capillary surface and then introducing it into the source of the mass spectrometer. Similarly, for a liquid sample, a capillary tube is dipped into the sample to just coat the surface or a few microliters may be applied to the tip of a capillary before being analyzed by Atmospheric Pressure Chemical Ionization in both positive and negative mode.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>A rodenticide containing brodifacoum, black tar heroin and its impurities (morphine, codeine, noscapine, papaverine, and monoacetylmorphine), crack cocaine and 1\u2010methylaminoanthraquinone dyestuff were successfully analyzed directly without any sample preparation. All compounds were detected using full scan mass spectrometry (MS), followed by confirmation by MS\/MS. Preliminary results suggest that this technique could be used for quantitation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS<\/jats:title>\n                    <jats:p>\n                      Interfacing the ASAP to an ion trap mass spectrometer allows the ability to perform full scan, MS\n                      <jats:sup>n<\/jats:sup>\n                      experiments, and rapid positive\/negative switching from a single sample introduction. Because of these features, this instrument is very useful for rapid, routine analysis and for confirmation with the use of in\u2010house MS\/MS libraries. Published in 2014. This article is a U.S. Government work and is in the public domain in the USA.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/rcm.7097","type":"journal-article","created":{"date-parts":[[2014,12,12]],"date-time":"2014-12-12T00:31:37Z","timestamp":1418344297000},"page":"205-212","source":"Crossref","is-referenced-by-count":20,"title":["Rapid analysis of forensic samples using an atmospheric solid analysis probe interfaced to a linear ion trap mass spectrometer"],"prefix":"10.1002","volume":"29","author":[{"given":"Eshwar","family":"Jagerdeo","sequence":"first","affiliation":[{"name":"Federal Bureau of Investigation Laboratory  Quantico VA 22135 USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay A.","family":"Clark","sequence":"additional","affiliation":[{"name":"Federal Bureau of Investigation Laboratory  Quantico VA 22135 USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey N.","family":"Leibowitz","sequence":"additional","affiliation":[{"name":"Federal Bureau of Investigation Laboratory  Quantico VA 22135 USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Louis J.","family":"Reda","sequence":"additional","affiliation":[{"name":"Federal Bureau of Investigation Laboratory  Quantico VA 22135 USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2014,12,11]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1039\/b925579f"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1039\/b925257f"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00216-010-3808-3"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.aca.2011.06.017"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1021\/ac200918u"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1126\/science.1104404"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1126\/science.1119426"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1021\/ac050162j"},{"key":"e_1_2_6_10_1","volume-title":"The Encyclopedia of Mass Spectrometry, vol. 6: Ionization Methods","author":"Laramee J. A.","year":"2007"},{"key":"e_1_2_6_11_1","first-page":"1","volume-title":"Encyclopedia of Analytical Chemistry","author":"Cody R. B.","year":"2010"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00216-009-2659-2"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1039\/B418697D"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1039\/b602614a"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1039\/b700236j"},{"key":"e_1_2_6_16_1","doi-asserted-by":"publisher","DOI":"10.1039\/b703655h"},{"key":"e_1_2_6_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/s12566-010-0019-5"},{"key":"e_1_2_6_18_1","doi-asserted-by":"publisher","DOI":"10.1021\/ac1029117"},{"key":"e_1_2_6_19_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.forsciint.2013.07.006"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jasms.2009.01.010"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1021\/ac8018137"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/rcm.6274"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.aca.2011.09.016"},{"key":"e_1_2_6_24_1","doi-asserted-by":"publisher","DOI":"10.5740\/jaoacint.12-160"},{"key":"e_1_2_6_25_1","doi-asserted-by":"publisher","DOI":"10.1021\/ac051470k"},{"key":"e_1_2_6_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jasms.2007.03.032"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jasms.2009.04.010"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1021\/ac901324j"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(05)70773-X"},{"key":"e_1_2_6_30_1","first-page":"186","article-title":"Opium and its alkaloids","volume":"66","author":"Schiff P. L.","year":"2002","journal-title":"Am. J. Pharm. Educ."},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1093\/chromsci\/44.2.86"},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.1080\/16066350500527797"},{"key":"e_1_2_6_33_1","doi-asserted-by":"publisher","DOI":"10.1002\/rcm.4459"},{"key":"e_1_2_6_34_1","doi-asserted-by":"publisher","DOI":"10.1039\/b209521c"},{"key":"e_1_2_6_35_1","doi-asserted-by":"publisher","DOI":"10.1002\/rcm.1268"},{"key":"e_1_2_6_36_1","unstructured":"A.Senior L.Williams R.Jones H.Lodder G.Davies G.Jones.Biotage LLC. A simplified approach to the extraction of benzodiazepines from urine using supported liquid extraction (SLE) prior to GC\u2010MS analysis 2012. Available:http:\/\/www.biotage.com\/literature\/search?advanced=0&biotage_sitebundle_documentsearchtype[product_page_id]=&biotage_sitebundle_documentsearchtype[search_query]=benzodiazepines&display_type=0&keywords[13][]=0&keywords[6][]=0&keywords[9][]=0&order_by=title%20asc&rpp=20."}],"container-title":["Rapid Communications in Mass Spectrometry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Frcm.7097","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Frcm.7097","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/rcm.7097","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,26]],"date-time":"2025-10-26T13:59:25Z","timestamp":1761487165000},"score":1,"resource":{"primary":{"URL":"https:\/\/analyticalsciencejournals.onlinelibrary.wiley.com\/doi\/10.1002\/rcm.7097"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,12,11]]},"references-count":35,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2015,1,30]]}},"alternative-id":["10.1002\/rcm.7097"],"URL":"https:\/\/doi.org\/10.1002\/rcm.7097","archive":["Portico"],"relation":{},"ISSN":["0951-4198","1097-0231"],"issn-type":[{"value":"0951-4198","type":"print"},{"value":"1097-0231","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,12,11]]}}}