{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,17]],"date-time":"2023-10-17T09:56:05Z","timestamp":1697536565330},"reference-count":13,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2012,2,28]],"date-time":"2012-02-28T00:00:00Z","timestamp":1330387200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Robotics Computer Surgery"],"published-print":{"date-parts":[[2012,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>The purpose of this study is to present a new navigation device for deformity correction surgery and to evaluate its accuracy compared with a conventional electromagnetic navigation system in tracking the orientation of synthetic bony fragments.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>This system consists of three sensors and software which can be installed on any personal computer. One sensor is mounted about 1\u2009m above the other sensors. The remaining two sensors are fixed to the bone fragments using Schanz screws. Data from all three sensors are computed using the software to estimate the change in position of the sensors. For the first part of the study 118 planned one and two plane deformities in 5\u00b0 increments were created. For the second part of the study complex random 3\u2010dimensional deformities were created (300 valid measurements).<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>The mean absolute differences between measurements of the electromagnetic and mini\u2010navigator were 1.8\u2009\u00b1\u20091.9\u00b0 in the coronal, 1.1\u2009\u00b1\u20091.1\u00b0 in the sagittal and 0.8\u2009\u00b1\u20090.7\u00b0 in the transverse plane. Absolute differences between mini\u2010navigator and Fastrak measurements were significantly affected by the magnitude of the deformity (P\u2009&lt;\u20090.0001) with better accuracy for lower deformities.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>We believe that this new technology is appealing, because of its high accuracy and lower planned costs compared with conventional navigation devices. Copyright \u00a9 2012 John Wiley &amp; Sons, Ltd.<\/jats:p><\/jats:sec>","DOI":"10.1002\/rcs.1424","type":"journal-article","created":{"date-parts":[[2012,2,28]],"date-time":"2012-02-28T13:18:55Z","timestamp":1330435135000},"page":"319-326","source":"Crossref","is-referenced-by-count":1,"title":["Mini\u2010navigator: a new system for navigated deformity corrections"],"prefix":"10.1002","volume":"8","author":[{"given":"Emmanouil","family":"Liodakis","sequence":"first","affiliation":[{"name":"MHH Trauma  Carl\u2010Neuberg Str 1 Hannover 30625 Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Macke","sequence":"additional","affiliation":[{"name":"MHH Trauma  Carl\u2010Neuberg Str 1 Hannover 30625 Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed","family":"Kenawey","sequence":"additional","affiliation":[{"name":"MHH Trauma  Carl\u2010Neuberg Str 1 Hannover 30625 Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Krettek","sequence":"additional","affiliation":[{"name":"MHH Trauma  Carl\u2010Neuberg Str 1 Hannover 30625 Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2012,2,28]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-008-0574-1"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-199710000-00023"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-006-0035-8"},{"key":"e_1_2_6_5_1","doi-asserted-by":"crossref","first-page":"165","DOI":"10.3233\/THC-2010-0579","article-title":"The axis\u2010board: an alternative to the cable technique for intraoperative assessment of lower limb alignment","volume":"18","author":"Liodakis E","year":"2010","journal-title":"Technol Health Care"},{"key":"e_1_2_6_6_1","first-page":"1043","article-title":"Precision in orthopaedic computer navigation","volume":"35","author":"Hufner T","year":"2006","journal-title":"Orthopade"},{"key":"e_1_2_6_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/BFb0056211"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1053\/j.oto.2006.12.001"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2007.07.005"},{"key":"e_1_2_6_10_1","first-page":"180","volume":"21","author":"Phillips R","year":"2007","journal-title":"The accuracy of surgical navigation for orthopaedic surgery Curr Orthopaed"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.328.7441.702"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.85B3.14212"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.85B6.13722"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-005-0038-9"}],"container-title":["The International Journal of Medical Robotics and Computer Assisted Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Frcs.1424","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Frcs.1424","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/rcs.1424","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,16]],"date-time":"2023-10-16T03:38:09Z","timestamp":1697427489000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/rcs.1424"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,2,28]]},"references-count":13,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2012,9]]}},"alternative-id":["10.1002\/rcs.1424"],"URL":"https:\/\/doi.org\/10.1002\/rcs.1424","archive":["Portico"],"relation":{},"ISSN":["1478-5951","1478-596X"],"issn-type":[{"value":"1478-5951","type":"print"},{"value":"1478-596X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,2,28]]}}}