{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T19:50:33Z","timestamp":1787169033737,"version":"build-2736575974"},"reference-count":25,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2018,5,15]],"date-time":"2018-05-15T00:00:00Z","timestamp":1526342400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"funder":[{"name":"Shanghai Engineering Research Center for Intelligent Diagnosis & Treatment Instrument","award":["15DZ2252000"],"award-info":[{"award-number":["15DZ2252000"]}]}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Robotics Computer Surgery"],"published-print":{"date-parts":[[2018,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Endovascular interventional surgery (EIS) is performed under a high radiation environment at the sacrifice of surgeons' health. This paper introduces a novel endovascular interventional surgical robot that aims to reduce radiation to surgeons and physical stress imposed by lead aprons during fluoroscopic X\u2010ray guided catheter intervention.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>The unique mechanical structure allowed the surgeon to manipulate the axial and radial motion of the catheter and guide wire. Four catheter manipulators (to manipulate the catheter and guide wire), and a control console which consists of four joysticks, several buttons and two twist switches (to control the catheter manipulators) were presented. The entire robotic system was established on a master\u2013slave control structure through CAN (Controller Area Network) bus communication, meanwhile, the slave side of this robotic system showed highly accurate control over velocity and displacement with PID controlling method.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The robotic system was tested and passed in vitro and animal experiments. Through functionality evaluation, the manipulators were able to complete interventional surgical motion both independently and cooperatively. The robotic surgery was performed successfully in an adult female pig and demonstrated the feasibility of superior mesenteric and common iliac artery stent implantation. The entire robotic system met the clinical requirements of EIS.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The results show that the system has the ability to imitate the movements of surgeons and to accomplish the axial and radial motions with consistency and high\u2010accuracy.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1002\/rcs.1915","type":"journal-article","created":{"date-parts":[[2018,5,15]],"date-time":"2018-05-15T05:07:02Z","timestamp":1526360822000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Design and Performance Evaluation of Real\u2010time Endovascular Interventional Surgical Robotic System with High Accuracy"],"prefix":"10.1002","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3969-5148","authenticated-orcid":false,"given":"Kundong","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Instrument Science and Engineering Shanghai Jiao Tong University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4681-6171","authenticated-orcid":false,"given":"Bing","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Instrument Science and Engineering Shanghai Jiao Tong University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qingsheng","family":"Lu","sequence":"additional","affiliation":[{"name":"Department of Vascular Surgery Changhai Hospital  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongbing","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Instrument Science and Engineering Shanghai Jiao Tong University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manhua","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Instrument Science and Engineering Shanghai Jiao Tong University  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Shen","sequence":"additional","affiliation":[{"name":"Department of Vascular Surgery Changhai Hospital  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhuoyan","family":"Xu","sequence":"additional","affiliation":[{"name":"Department of Vascular Surgery Changhai Hospital  Shanghai China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2018,5,15]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8183.2006.00202.x"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.106.677369"},{"issue":"8","key":"e_1_2_7_4_1","first-page":"1653","article-title":"Intervention in the treatment of neuroendovascular status and development of science Chinede","volume":"20","author":"Li BM","year":"2005","journal-title":"Journal of General Practice"},{"key":"e_1_2_7_5_1","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/S0002-9149(96)00678-9","article-title":"Prevalence of spinal disc disease among interventional cardiologists","volume":"79","author":"Ross AM","year":"1997","journal-title":"Amer J Cardiol"},{"key":"e_1_2_7_6_1","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1259\/bjr.71.849.10195011","article-title":"Radiation exposure to medical staff in interventional and cardiac radiology","volume":"71","author":"Vano E","year":"1998","journal-title":"Brit J Radiol"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jvs.2010.06.154"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1002\/rcs.1650"},{"issue":"5","key":"e_1_2_7_9_1","first-page":"696","article-title":"Master\u2010slave Interactive Control and Implementation for Minimally Invasive Endovascular Interventional Robots","volume":"42","author":"Feng ZQ","year":"2016","journal-title":"ACTA AUTOMATICA SINICA"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1504\/IJMA.2012.046583"},{"key":"e_1_2_7_11_1","volume-title":"Remote Control of Laparoscopic Minimally Invasive Surgical Robot and Experiments","author":"Liu YL","year":"2014"},{"issue":"2","key":"e_1_2_7_12_1","first-page":"130","article-title":"A Robotic System for Microsurgery: the \u2018MicroHand\u2019 system","volume":"28","author":"Wang SX","year":"2006","journal-title":"J ROBOT"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-005-0325-y"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2006.00556.x"},{"key":"e_1_2_7_15_1","unstructured":"MaX GuoS.Remote Operation by a Developed Robotic Catheter Manipulating System.Proceeding of the 11th World Congress on Intelligent Control and Automation Shenyang China June 29\u2013July 4 2014."},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1002\/rcs.212"},{"key":"e_1_2_7_17_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10840-006-9022-8"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1177\/15910199010070S116"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.0000125126.83579.1B"},{"key":"e_1_2_7_20_1","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.1161\/CIRCULATIONAHA.106.672162","article-title":"Remote magnetic navigation to guide endocardial and epicardial catheter mapping of scar\u2010related ventricular tachycardia","volume":"115","author":"ryana A","year":"2007","journal-title":"Circulation"},{"key":"e_1_2_7_21_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehl447"},{"key":"e_1_2_7_22_1","doi-asserted-by":"crossref","first-page":"1556","DOI":"10.1016\/j.hrthm.2008.08.028","article-title":"Robotic versus conventional ablation for common\u2010type atrial flutter: a prospective randomized trial to evaluate the effectiveness of remote catheter navigation","volume":"5","author":"Steven D","journal-title":"Heart Rhythm"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1540-8167.2009.01570.x"},{"key":"e_1_2_7_24_1","article-title":"Reduced Fluoroscopy During Atrial Fibrillation Ablation: Benefits of Robotic Guided Navigation","author":"Steven D","year":"2009","journal-title":"J Cardiovasc Electrophysiol"},{"key":"e_1_2_7_25_1","unstructured":"GuoXX.Design and Implementation of Interface IP Core for CAN Bus Controller.Northeast Normal University China 2011."},{"key":"e_1_2_7_26_1","doi-asserted-by":"crossref","unstructured":"MaX GuoS et al.Development of a PID Controller for a Novel Robotic Catheter System.Proceeding of the 2011 IEEE\/ICME International Conference on Complex Medical EngineeringMay 22\u201325 Harbin China.","DOI":"10.1109\/ICCME.2011.5876706"}],"container-title":["The International Journal of Medical Robotics and Computer Assisted Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Frcs.1915","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/rcs.1915","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,17]],"date-time":"2023-09-17T18:05:22Z","timestamp":1694973922000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/rcs.1915"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5,15]]},"references-count":25,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018,10]]}},"alternative-id":["10.1002\/rcs.1915"],"URL":"https:\/\/doi.org\/10.1002\/rcs.1915","archive":["Portico"],"relation":{},"ISSN":["1478-5951","1478-596X"],"issn-type":[{"value":"1478-5951","type":"print"},{"value":"1478-596X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,5,15]]},"assertion":[{"value":"2017-05-18","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-03-19","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-05-15","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e1915"}}