{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,4]],"date-time":"2026-01-04T02:52:04Z","timestamp":1767495124514,"version":"3.41.2"},"reference-count":41,"publisher":"Wiley","issue":"4","license":[{"start":{"date-parts":[[2021,4,25]],"date-time":"2021-04-25T00:00:00Z","timestamp":1619308800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Robotics Computer Surgery"],"published-print":{"date-parts":[[2021,8]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>The purpose of this study was to compare the accuracy of this new HURWA robotic\u2010assisted total knee arthroplasty (TKA) technique to the accuracy of the conventional technique in a sawbone model.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>The HURWA robotic\u2010assisted TKA system was applied in the robotic group. After bone resection, all of these sawbones were scanned by the use of a structured light scanning system. Measurements of bone resections, femoral coronal and sagittal measurements, and tibial coronal and sagittal measurements were recorded.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Compared to the conventional technique, the HURWA robotic\u2010assisted system significantly improved the accuracy of the bone resection levels and angles. In the robotic group, the accuracy of all of the bone resection levels was below 0.6\u00a0mm (with standard deviation [SD] below 0.6\u00a0mm), and all of the bone resection angles were below 0.6\u00b0 (with SD below 0.4\u00b0).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>Our data suggest that this novel HURWA robotic\u2010assisted system can significantly improve the accuracy of bone resection levels and angles.<\/jats:p><\/jats:sec>","DOI":"10.1002\/rcs.2263","type":"journal-article","created":{"date-parts":[[2021,4,10]],"date-time":"2021-04-10T07:25:05Z","timestamp":1618039505000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Better precision of a new robotically assisted system for total knee arthroplasty compared to conventional techniques: A sawbone model study"],"prefix":"10.1002","volume":"17","author":[{"given":"Zheng","family":"Li","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery Peking Union Medical College Hospital Chinese Academy of Medical Sciences and Peking Union Medical College  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xin","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Peking Union Medical College Hospital Chinese Academy of Medical Sciences and Peking Union Medical College  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaofeng","family":"Zhang","sequence":"additional","affiliation":[{"name":"BEIJING HURWA\u2010ROBOT Medical Technology Co.Ltd  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jun","family":"Yan","sequence":"additional","affiliation":[{"name":"BEIJING HURWA\u2010ROBOT Medical Technology Co.Ltd  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Youdong","family":"Song","sequence":"additional","affiliation":[{"name":"BEIJING HURWA\u2010ROBOT Medical Technology Co.Ltd  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yujia","family":"Huo","sequence":"additional","affiliation":[{"name":"BEIJING HURWA\u2010ROBOT Medical Technology Co.Ltd  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1733-8940","authenticated-orcid":false,"given":"Jin","family":"Lin","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery Peking Union Medical College Hospital Chinese Academy of Medical Sciences and Peking Union Medical College  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2021,4,25]]},"reference":[{"key":"e_1_2_7_2_1","article-title":"Patients' pre\u2010operative expectations of total knee arthroplasty and satisfaction with outcomes at one year: a prospective cohort study","author":"Hawker G","year":"2020","journal-title":"Arthritis Rheumatol"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2020.11.019"},{"key":"e_1_2_7_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2020.11.013"},{"key":"e_1_2_7_5_1","doi-asserted-by":"publisher","DOI":"10.14814\/phy2.12671"},{"key":"e_1_2_7_6_1","article-title":"Preoperative risk factors associated with chronic pain profiles following total knee arthroplasty","author":"Lindberg M","year":"2020","journal-title":"Eur J Pain (Lond)"},{"key":"e_1_2_7_7_1","article-title":"Impact of postoperative zolpidem use on primary total knee arthroplasty: a retrospective matched\u2010controlled analysis of a private insurance database","author":"Ardeljan A","year":"2020","journal-title":"J Arthroplast"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.20.01034"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jos.2016.06.003"},{"key":"e_1_2_7_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-015-3949-1"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-011-1483-3"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2018.04.010"},{"key":"e_1_2_7_13_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2020.10.053"},{"key":"e_1_2_7_14_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm9082439"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.arth.2020.06.036"},{"key":"e_1_2_7_16_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-020-04547-4"},{"key":"e_1_2_7_17_1","article-title":"Patch test results and outcome in patients with Complications from total knee arthroplasty: a consecutive case series","author":"Sasseville D","year":"2019","journal-title":"J Knee Surg"},{"key":"e_1_2_7_18_1","doi-asserted-by":"publisher","DOI":"10.1302\/2633-1462.12.BJO-2019-0004.R1"},{"key":"e_1_2_7_19_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-020-06353-2"},{"key":"e_1_2_7_20_1","doi-asserted-by":"publisher","DOI":"10.1002\/jor.24923"},{"key":"e_1_2_7_21_1","article-title":"Progression of health\u2010related quality of life of patients waiting for total knee arthroplasty","author":"Ho K","year":"2020","journal-title":"J Eval Clin Pract"},{"key":"e_1_2_7_22_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13102-020-0157-1"},{"key":"e_1_2_7_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-020-04890-6"},{"key":"e_1_2_7_24_1","first-page":"1","article-title":"Chronic postsurgical pain after total knee arthroplasty: a prospective cohort study in Japanese population","author":"Aso K","year":"2020","journal-title":"Mod Rheumatol"},{"key":"e_1_2_7_25_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11999-014-3785-5"},{"key":"e_1_2_7_26_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-014-1934-7"},{"key":"e_1_2_7_27_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-004-0759-1"},{"key":"e_1_2_7_28_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.93B3.25467"},{"key":"e_1_2_7_29_1","doi-asserted-by":"publisher","DOI":"10.1007\/s13304-020-00896-2"},{"key":"e_1_2_7_30_1","doi-asserted-by":"publisher","DOI":"10.1002\/rcs.2157"},{"key":"e_1_2_7_31_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-016-0422-x"},{"key":"e_1_2_7_32_1","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20110826-12"},{"key":"e_1_2_7_33_1","doi-asserted-by":"publisher","DOI":"10.1302\/0301-620X.102B11.BJJ-2020-1166.R1"},{"key":"e_1_2_7_34_1","article-title":"How does robotic\u2010arm assisted technology influence total knee arthroplasty implant placement for surgeons in fellowship training?","author":"Scholl L","year":"2020","journal-title":"J Knee Surg"},{"key":"e_1_2_7_35_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13063-020-4123-8"},{"key":"e_1_2_7_36_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-020-06283-z"},{"key":"e_1_2_7_37_1","article-title":"Accuracy of bone resection in MAKO total knee robotic\u2010assisted surgery","author":"Sires J","year":"2019","journal-title":"J Knee Surg"},{"key":"e_1_2_7_38_1","article-title":"Better accuracy and reproducibility of a new robotically\u2010assisted system for total knee arthroplasty compared to conventional instrumentation: a cadaveric study","author":"Seidenstein A","year":"2020","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"e_1_2_7_39_1","article-title":"Three\u2010dimensional scanners for soft\u2010tissue facial assessment in clinical practice","author":"Petrides G","year":"2020","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"e_1_2_7_40_1","doi-asserted-by":"publisher","DOI":"10.3390\/s20205778"},{"key":"e_1_2_7_41_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-016-1381-8"},{"key":"e_1_2_7_42_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-020-02129-8"}],"container-title":["The International Journal of Medical Robotics and Computer Assisted Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/rcs.2263","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/rcs.2263","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/rcs.2263","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,28]],"date-time":"2023-08-28T06:47:07Z","timestamp":1693205227000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/rcs.2263"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,25]]},"references-count":41,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021,8]]}},"alternative-id":["10.1002\/rcs.2263"],"URL":"https:\/\/doi.org\/10.1002\/rcs.2263","archive":["Portico"],"relation":{},"ISSN":["1478-5951","1478-596X"],"issn-type":[{"type":"print","value":"1478-5951"},{"type":"electronic","value":"1478-596X"}],"subject":[],"published":{"date-parts":[[2021,4,25]]},"assertion":[{"value":"2021-01-28","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-02-23","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-04-25","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e2263"}}