{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,12]],"date-time":"2024-09-12T06:36:15Z","timestamp":1726122975133},"reference-count":39,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2009,1,23]],"date-time":"2009-01-23T00:00:00Z","timestamp":1232668800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Robotics Computer Surgery"],"published-print":{"date-parts":[[2009,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>The reduction of long bone fractures treated with external fixation is usually performed with fluoroscopic images, which include several disadvantages: 2D information, distortions, and irradiation to the patient and the surgical team. This article presents a new navigation technique to control the reduction of such fractures while minimizing the irradiation.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Optically tracked markers are fixed to pins inserted into the bone fragments. These last are modelled using two initial calibrated radiographs. The models can be improved with several types of anatomical data and are displayed in real time.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>This navigation system was tested on dry bones and an anatomical specimen leg.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>This new technique allows the visualization of the fracture in real time and from any viewpoint during the reduction. Irradiation is minimized using only two X\u2010ray images. Copyright \u00a9 2009 John Wiley &amp; Sons, Ltd.<\/jats:p><\/jats:sec>","DOI":"10.1002\/rcs.240","type":"journal-article","created":{"date-parts":[[2009,1,23]],"date-time":"2009-01-23T13:42:22Z","timestamp":1232718142000},"page":"99-109","source":"Crossref","is-referenced-by-count":9,"title":["Conception of a navigation system controlling diaphyseal fracture reduction treated with external fixation"],"prefix":"10.1002","volume":"5","author":[{"given":"T.","family":"Leloup","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"W. El","family":"Kazzi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F.","family":"Schuind","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.","family":"Warz\u00e9e","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2009,1,23]]},"reference":[{"issue":"4","key":"e_1_2_1_2_2","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1302\/0301-620X.71B4.2768297","article-title":"Surgical implications of varus deformity of knee with obliquity of joint surfaces","volume":"71","author":"Cooke TD","year":"1989","journal-title":"J Bone Joint Surg Br"},{"issue":"4","key":"e_1_2_1_3_2","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/S0030-5898(20)31511-X","article-title":"Treatment of malunions and mal\u2010nonunions of the femur and tibia by detailed preoperative planning and the Ilizarov techniques","volume":"21","author":"Paley D","year":"1990","journal-title":"Orthop Clin North Am"},{"issue":"3","key":"e_1_2_1_4_2","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/S0030-5898(20)31922-2","article-title":"Biomechanics of malalignment","volume":"25","author":"Chao EYS","year":"1994","journal-title":"Orthop Clin North Am"},{"issue":"11","key":"e_1_2_1_5_2","doi-asserted-by":"crossref","first-page":"1746","DOI":"10.2106\/00004623-200111000-00020","article-title":"Surgeons' preferences for the operative treatment of fractures of the tibial shaft: an international survey","volume":"83","author":"Bhandari M","year":"2001","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"e_1_2_1_6_2","first-page":"272","article-title":"Management of tibial fractures with the orthofix dynamic external fixator","volume":"36","author":"Keating JF","year":"1991","journal-title":"J R Coll Surg Edinb"},{"issue":"9","key":"e_1_2_1_7_2","first-page":"440","article-title":"Results of treatment of 202 fresh tibial shaft fractures, managed with unilateral external fixation (monofixateur)","volume":"92","author":"Krettek C","year":"1989","journal-title":"Unfallchirurgie"},{"issue":"3","key":"e_1_2_1_8_2","first-page":"145","article-title":"Tibial shaft fractures treated by the external fixation method","volume":"13","author":"Stojkovic B","year":"2006","journal-title":"Med Biol"},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1002\/igs.1018"},{"issue":"6","key":"e_1_2_1_10_2","doi-asserted-by":"crossref","first-page":"271","DOI":"10.3109\/10929089809148148","article-title":"FRACAS: a system for computer\u2010aided image\u2010guided long bone fracture surgery","volume":"3","author":"Joskowicz L","year":"1999","journal-title":"Comput Aided Surg"},{"key":"e_1_2_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2005.06.002"},{"key":"e_1_2_1_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2007.05.005"},{"key":"e_1_2_1_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ics.2004.03.335"},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1002\/1097-0150(2000)5:5<311::AID-IGS1>3.0.CO;2-J"},{"key":"e_1_2_1_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.cmpb.2007.03.002"},{"issue":"3","key":"e_1_2_1_16_2","first-page":"265","article-title":"Biomechanical study of the Hoffman external fixation device","volume":"38","author":"Burny F","year":"1972","journal-title":"Acta Orthop Belg"},{"key":"e_1_2_1_17_2","doi-asserted-by":"publisher","DOI":"10.1259\/imaging\/27841634"},{"key":"e_1_2_1_18_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF00133570"},{"key":"e_1_2_1_19_2","volume-title":"Computational Geometry, Fluid Mechanics, Computer Vision, and Materials Science","author":"Sethian J","year":"1999"},{"key":"e_1_2_1_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/B978-012077790-7\/50014-X"},{"key":"e_1_2_1_21_2","doi-asserted-by":"publisher","DOI":"10.1006\/gmip.1998.0475"},{"key":"e_1_2_1_22_2","doi-asserted-by":"publisher","DOI":"10.1109\/42.832960"},{"key":"e_1_2_1_23_2","doi-asserted-by":"publisher","DOI":"10.1006\/gmip.1998.0480"},{"key":"e_1_2_1_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/BF01386390"},{"key":"e_1_2_1_25_2","doi-asserted-by":"publisher","DOI":"10.1006\/cviu.1996.0018"},{"key":"e_1_2_1_26_2","doi-asserted-by":"publisher","DOI":"10.1007\/s003710050201"},{"key":"e_1_2_1_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0097-8493(98)00120-4"},{"key":"e_1_2_1_28_2","doi-asserted-by":"publisher","DOI":"10.1109\/34.121791"},{"key":"e_1_2_1_29_2","doi-asserted-by":"publisher","DOI":"10.1109\/42.736023"},{"key":"e_1_2_1_30_2","unstructured":"HamadehA SautotP Lavall\u00e9eS et al.Towards automatic registration between CT and X\u2010ray images cooperation between 2D\/3D registration and 2D edge detection. InProceedings of the 2nd International Symposium on Medical Robotics and Computer\u2010Assisted Surgery 1995 Baltimore MD USA. Wiley: New York 1995;39\u201346."},{"key":"e_1_2_1_31_2","doi-asserted-by":"publisher","DOI":"10.1006\/cviu.1994.1066"},{"key":"e_1_2_1_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1361-8415(99)80026-7"},{"key":"e_1_2_1_33_2","doi-asserted-by":"crossref","unstructured":"SanderPV GuX GortlerSJ et al.Silhouette clipping. InProceedings of the 27th Annual Conference on Computer Graphics and Interactive Techniques.ACM Press\/Addison\u2010Wesley: New York 2000;327\u2013334.","DOI":"10.1145\/344779.344935"},{"key":"e_1_2_1_34_2","doi-asserted-by":"publisher","DOI":"10.1109\/42.736023"},{"key":"e_1_2_1_35_2","doi-asserted-by":"publisher","DOI":"10.1109\/2945.773810"},{"key":"e_1_2_1_36_2","doi-asserted-by":"publisher","DOI":"10.1148\/radiographics.21.4.g01jl271033"},{"key":"e_1_2_1_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.radi.2004.02.002"},{"issue":"1","key":"e_1_2_1_38_2","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1302\/0301-620X.63B1.7009621","article-title":"External fixation for complicated tibial fractures","volume":"63","author":"Edge AJ","year":"1981","journal-title":"J Bone Joint Surg Br"},{"key":"e_1_2_1_39_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1361-8415(99)80020-6"},{"key":"e_1_2_1_40_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11517-008-0353-8"}],"container-title":["The International Journal of Medical Robotics and Computer Assisted Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Frcs.240","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/rcs.240","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,13]],"date-time":"2023-11-13T19:01:31Z","timestamp":1699902091000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/rcs.240"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,1,23]]},"references-count":39,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2009,3]]}},"alternative-id":["10.1002\/rcs.240"],"URL":"https:\/\/doi.org\/10.1002\/rcs.240","archive":["Portico"],"relation":{},"ISSN":["1478-5951","1478-596X"],"issn-type":[{"value":"1478-5951","type":"print"},{"value":"1478-596X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,1,23]]}}}