{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,21]],"date-time":"2026-01-21T23:57:52Z","timestamp":1769039872940,"version":"3.49.0"},"reference-count":35,"publisher":"Wiley","issue":"1","license":[{"start":{"date-parts":[[2023,12,28]],"date-time":"2023-12-28T00:00:00Z","timestamp":1703721600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Robotics Computer Surgery"],"published-print":{"date-parts":[[2024,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>To assess the accuracy of robot\u2010assisted Magerl screw placement and explore the factors affecting the accuracy.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>A retrospective analysis of patients who underwent robot\u2010assisted Magerl screw placement was performed. The accuracy of Magerl screw placement was evaluated according to the Gertzbein and Robbins scale.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>47 Magerl screws were placed in 24 consecutive patients. 32 Magerl screws were narrower than the C2 isthmus height and 26 of them were grade A. 15 Magerl screws were wider than the C2 isthmus height and all of them were grade B. Temporary fixation after decompression and a smaller difference between the C2 isthmus height and screw diameter were associated with a higher probability of cortical breach.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>The accuracy of robot\u2010assisted Magerl screw placement was excellent. Temporary fixation after decompression and a smaller difference between the C2 isthmus height and screw diameter increased the risk of cortical breach.<\/jats:p><\/jats:sec>","DOI":"10.1002\/rcs.2603","type":"journal-article","created":{"date-parts":[[2023,12,29]],"date-time":"2023-12-29T07:28:27Z","timestamp":1703834907000},"update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Accuracy and risk factors of Magerl screw placement in robot\u2010assisted atlantoaxial surgery: A case series study"],"prefix":"10.1002","volume":"20","author":[{"given":"Wu","family":"Jiayuan","sequence":"first","affiliation":[{"name":"Spine Department Beijing Jishuitan Hospital Capital Medical University  Beijing China"},{"name":"Beijing Key Laboratory of Robotic Orthopaedics  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Yi","sequence":"additional","affiliation":[{"name":"Spine Department Beijing Jishuitan Hospital Capital Medical University  Beijing China"},{"name":"Beijing Key Laboratory of Robotic Orthopaedics  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Duan","family":"Fangfang","sequence":"additional","affiliation":[{"name":"Epidemiological Research Department Beijing Jishuitan Hospital Capital Medical University  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"He","family":"Da","sequence":"additional","affiliation":[{"name":"Spine Department Beijing Jishuitan Hospital Capital Medical University  Beijing China"},{"name":"Beijing Key Laboratory of Robotic Orthopaedics  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiang","family":"Xieyuan","sequence":"additional","affiliation":[{"name":"Trauma Orthopedics Beijing Jishuitan Hospital Capital Medical University  Beijing China"},{"name":"Beijing Jishuitan Orthopaedic Robot Engineering Research Center Co., Ltd.  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1067-600X","authenticated-orcid":false,"given":"Tian","family":"Wei","sequence":"additional","affiliation":[{"name":"Spine Department Beijing Jishuitan Hospital Capital Medical University  Beijing China"},{"name":"Beijing Key Laboratory of Robotic Orthopaedics  Beijing China"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2023,12,28]]},"reference":[{"key":"e_1_2_10_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/00002517\u2010199212000\u201000012"},{"key":"e_1_2_10_3_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00586\u2010011\u20101958\u20104"},{"key":"e_1_2_10_4_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00256\u2010006\u20100155\u20108"},{"key":"e_1_2_10_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.wneu.2012.03.012"},{"key":"e_1_2_10_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2015.07.008"},{"key":"e_1_2_10_7_1","doi-asserted-by":"publisher","DOI":"10.1097\/brs.0000000000001674"},{"key":"e_1_2_10_8_1","doi-asserted-by":"publisher","DOI":"10.3171\/2018.10.spine18487"},{"key":"e_1_2_10_9_1","doi-asserted-by":"publisher","DOI":"10.1097\/brs.0000000000003258"},{"key":"e_1_2_10_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/s11701\u2010019\u201001019\u20109"},{"key":"e_1_2_10_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10143\u2010016\u20100757\u20100"},{"key":"e_1_2_10_12_1","doi-asserted-by":"publisher","DOI":"10.3171\/2011.6.spine10809"},{"key":"e_1_2_10_13_1","doi-asserted-by":"publisher","DOI":"10.3171\/2022.7.spine22473"},{"key":"e_1_2_10_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00586\u2010022\u201007110\u20104"},{"issue":"3","key":"e_1_2_10_15_1","first-page":"149","article-title":"Surgical safety of cervical pedicle screw placement with orthopaedic surgery robot system","volume":"42","author":"Li Q","year":"2022","journal-title":"Chin J Orthop"},{"key":"e_1_2_10_16_1","article-title":"Anatomical and technical considerations of robot\u2010assisted cervical pedicle screw placement: a cadaveric study","author":"Mao JZ","year":"2022","journal-title":"Glob Spine J"},{"key":"e_1_2_10_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/os.12454"},{"key":"e_1_2_10_18_1","doi-asserted-by":"publisher","DOI":"10.1097\/00007632\u2010199001000\u201000004"},{"key":"e_1_2_10_19_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000240656.79060.18"},{"issue":"4","key":"e_1_2_10_20_1","first-page":"380","article-title":"The standard parameters and influential factors of cervical spine alignment and range of motion","volume":"34","author":"Wu B","year":"2014","journal-title":"Chin J Orthop"},{"key":"e_1_2_10_21_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000051919.14927.57"},{"key":"e_1_2_10_22_1","doi-asserted-by":"publisher","DOI":"10.1155\/2022\/8508113"},{"key":"e_1_2_10_23_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00586\u2010015\u20103974\u20102"},{"key":"e_1_2_10_24_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00586\u2010022\u201007110\u20104"},{"key":"e_1_2_10_25_1","doi-asserted-by":"publisher","DOI":"10.1186\/s12893\u2010022\u201001826\u20102"},{"key":"e_1_2_10_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2022.04.015"},{"key":"e_1_2_10_27_1","doi-asserted-by":"publisher","DOI":"10.21037\/jss.2020.03.07"},{"key":"e_1_2_10_28_1","doi-asserted-by":"publisher","DOI":"10.1177\/15563316211026652"},{"key":"e_1_2_10_29_1","doi-asserted-by":"publisher","DOI":"10.1080\/17434440.2020.1699405"},{"key":"e_1_2_10_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2021.08.014"},{"key":"e_1_2_10_31_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00276\u2010021\u201002707\u20108"},{"key":"e_1_2_10_32_1","doi-asserted-by":"publisher","DOI":"10.1097\/01.brs.0000210263.87578.65"},{"key":"e_1_2_10_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.spinee.2013.04.005"},{"key":"e_1_2_10_34_1","doi-asserted-by":"publisher","DOI":"10.14245\/ns.2142560.180"},{"key":"e_1_2_10_35_1","doi-asserted-by":"publisher","DOI":"10.21037\/jss.2019.11.13"},{"key":"e_1_2_10_36_1","doi-asserted-by":"publisher","DOI":"10.3171\/2021.10.focus21496"}],"container-title":["The International Journal of Medical Robotics and Computer Assisted Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/rcs.2603","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,29]],"date-time":"2024-07-29T08:32:52Z","timestamp":1722241972000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/rcs.2603"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,28]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,2]]}},"alternative-id":["10.1002\/rcs.2603"],"URL":"https:\/\/doi.org\/10.1002\/rcs.2603","archive":["Portico"],"relation":{},"ISSN":["1478-5951","1478-596X"],"issn-type":[{"value":"1478-5951","type":"print"},{"value":"1478-596X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,28]]},"assertion":[{"value":"2023-08-27","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-11-24","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-12-28","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e2603"}}