{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T07:01:42Z","timestamp":1780556502387,"version":"3.54.1"},"reference-count":102,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2019,3,28]],"date-time":"2019-03-28T00:00:00Z","timestamp":1553731200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Structural Concrete"],"published-print":{"date-parts":[[2019,6]]},"abstract":"<jats:p>The technology of prestressing concrete structures has been a well\u2010established field in structural engineering since the last century. Nowadays, new materials developed for reinforcing concrete structures, such as fibre\u2010reinforced polymers (FRPs), open further possibilities for engineers. FRP tendons are more and more often investigated as an efficient and suitable material for prestressing, and there are already some field applications of this technology. This paper aims to describe the current state of knowledge in the field of prestressing with FRP tendons, with regard to available materials, developed anchorages and undertaken investigations. Researches conducted in areas such as bond strength, ductility, durability, long\u2010term behavior, and high\u2010temperature resistance are described and summarized. Our goal was to provide a summary of what has been achieved so far in the research field of prestressing concrete structures with FRP tendons; however, field applications and standardization issues are not part of this review.<\/jats:p>","DOI":"10.1002\/suco.201800347","type":"journal-article","created":{"date-parts":[[2019,3,29]],"date-time":"2019-03-29T06:55:36Z","timestamp":1553842536000},"page":"872-885","update-policy":"https:\/\/doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":42,"title":["Prestressing concrete members with fibre\u2010reinforced polymer reinforcement: State of research"],"prefix":"10.1002","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3847-3631","authenticated-orcid":false,"given":"Katarzyna","family":"Zdanowicz","sequence":"first","affiliation":[{"name":"Institute of Concrete Construction, Leibniz Universit\u00e4t Hannover  Hannover Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renata","family":"Kotynia","sequence":"additional","affiliation":[{"name":"Department of Concrete Structures Lodz University of Technology  Lodz Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steffen","family":"Marx","sequence":"additional","affiliation":[{"name":"Institute of Concrete Construction, Leibniz Universit\u00e4t Hannover  Hannover Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2019,3,28]]},"reference":[{"key":"e_1_2_6_2_1","volume-title":"Spannbeton f\u00fcr die Praxis","author":"Leonhardt F","year":"1955"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.engstruct.2015.06.052"},{"key":"e_1_2_6_4_1","volume-title":"Prestressing concrete structures with fibre\u2010reinforced polymers","author":"El\u2010Hacha R","year":"2008"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1201\/b16669"},{"key":"e_1_2_6_6_1","unstructured":"ACI. ACI 440.4R\u201004 Prestressing Concrete Structures with FRP Tendons (ACI 440.4R\u201004): ACI Committee 440; 2004 (2011)."},{"key":"e_1_2_6_7_1","volume-title":"Bulletin 40: FRP reinforcement in RC structures: Technical report","author":"fib F\u00e9d\u00e9ration internationale du b\u00e9ton","year":"2007"},{"key":"e_1_2_6_8_1","unstructured":"ThorhallssonE ZhelyazovT GunnarssonA SnaebjornssonJT. Concrete beams reinforced with prestressed basalt bars. In: fib F\u00e9d\u00e9ration internationale du b\u00e9ton editor. Proceedings of the fib Symposium: Concrete\u2013Innovation and Design 2015."},{"key":"e_1_2_6_9_1","volume-title":"Fib model code for concrete structures 2010","author":"F\u00e9d\u00e9ration international du b\u00e9ton (fib)","year":"2013"},{"key":"e_1_2_6_10_1","unstructured":"JuhaszK SchaulP. Shear behaviour of synthetic fibre reinforced concrete beams reinforced with FRP rebars. In: \u00d6sterreichische Bautechnik Vereinigung editor. Proceedings of the 11th Central European Congress on Concrete Engineering; 2015. p. 44\u201348."},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compositesb.2005.02.002"},{"key":"e_1_2_6_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.conbuildmat.2015.07.036"},{"key":"e_1_2_6_13_1","doi-asserted-by":"publisher","DOI":"10.1139\/l00-090"},{"key":"e_1_2_6_14_1","volume-title":"WTEC study on use of composite materials in civil infrastructure in Japan","author":"Karbhari VM","year":"1998"},{"issue":"1","key":"e_1_2_6_15_1","first-page":"1","article-title":"Prefabricated thin\u2010walled structural elements made from high performance concrete prestressed with CFRP wires","volume":"2","author":"Terrasi GP","year":"2012","journal-title":"J Mat Sci Res"},{"key":"e_1_2_6_16_1","unstructured":"Tokyo Rope. Carbon fibre composite cables (CFCC). Brochure;2014. Available from:http:\/\/www.tokyorope.co.jp\/english\/product\/cfcc\/."},{"key":"e_1_2_6_17_1","unstructured":"MagmaTech. RockBar. Technical Information;2016. Available from:http:\/\/magmatech.co.uk\/products\/rockbar\/."},{"issue":"6","key":"e_1_2_6_18_1","first-page":"54","article-title":"Anchorages for FRP reinforcement","volume":"15","author":"Erki MA","year":"1993","journal-title":"Concr Int"},{"issue":"1","key":"e_1_2_6_19_1","first-page":"86","article-title":"New concrete anchors for carbon Fiber\u2010reinforced polymer post\u2010tensioning tendons\u2014Part 1: State\u2010of\u2010the\u2010art review\/design","volume":"100","author":"Reda Taha MM","year":"2003","journal-title":"ACI Struct J"},{"key":"e_1_2_6_20_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.conbuildmat.2011.11.049"},{"key":"e_1_2_6_21_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)CC.1943-5614.0000171"},{"key":"e_1_2_6_22_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)CC.1943-5614.0000096"},{"key":"e_1_2_6_23_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)CC.1943-5614.0000367"},{"key":"e_1_2_6_24_1","unstructured":"RoddenberryM MtengaP JoshiK. Investigation of carbon fiber composite cables (CFCC) in prestressed concrete piles: Final report;2014."},{"issue":"5","key":"e_1_2_6_25_1","first-page":"29","article-title":"Field deployment of carbon\u2010fiber\u2010reinforced polymer in bridge applications","volume":"61","author":"Ushijima K","year":"2016","journal-title":"PCI J"},{"issue":"44","key":"e_1_2_6_26_1","first-page":"980","article-title":"Zwei CFK\u2010Kabel f\u00fcr die Storchenbr\u00fccke","volume":"114","author":"Meier U","year":"1996","journal-title":"Schweiz Ing Archit"},{"key":"e_1_2_6_27_1","doi-asserted-by":"publisher","DOI":"10.1007\/s13369-012-0185-6"},{"key":"e_1_2_6_28_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)CC.1943-5614.0000080"},{"key":"e_1_2_6_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compstruct.2014.10.024"},{"key":"e_1_2_6_30_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compositesb.2015.05.014"},{"key":"e_1_2_6_31_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-94-007-0723-8_136"},{"key":"e_1_2_6_32_1","doi-asserted-by":"publisher","DOI":"10.1002\/best.200590247"},{"key":"e_1_2_6_33_1","unstructured":"KolleggerJ GaubingerB HorvatitsJ. Vergussverankerung f\u00fcr Zugglieder aus Faserverbundwerkstoff\u2013Verst\u00e4rkung der Autobahn\u00fcberf\u00fchrung Golling. In: Stritzke J editor. 14. Dresdner Br\u00fcckenbausymposium;2004."},{"key":"e_1_2_6_34_1","doi-asserted-by":"publisher","DOI":"10.15554\/pcij.01012014.103.113"},{"key":"e_1_2_6_35_1","unstructured":"HaradaT IdemitsuT KhinM SoedaK WatanabeA. Studies of anchorage method for continuous fiber reinforcing material using highly expansive material. Concrete Library of JSCE (Translation from Proceedings of JSCE) 2000; 627\/B\u201044:145\u2013165."},{"key":"e_1_2_6_36_1","doi-asserted-by":"publisher","DOI":"10.3141\/2050-17"},{"key":"e_1_2_6_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.engstruct.2013.09.038"},{"key":"e_1_2_6_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.conbuildmat.2007.08.002"},{"key":"e_1_2_6_39_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)1090-0268(2001)5:3(200)"},{"key":"e_1_2_6_40_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)CC.1943-5614.0000306"},{"issue":"2","key":"e_1_2_6_41_1","first-page":"387","article-title":"Repair of prestressed concrete beams with damaged steel tendons using post\u2010tensioned carbon fiber\u2010reinforced polymer rods","volume":"111","author":"Burningham C","year":"2014","journal-title":"ACI Struct J"},{"issue":"4","key":"e_1_2_6_42_1","first-page":"521","article-title":"Reinforced concrete T\u2010beams externally prestressed with unbonded carbon fiber\u2010reinforced polymer tendons","volume":"109","author":"Bennitz A","year":"2012","journal-title":"ACI Struct J"},{"key":"e_1_2_6_43_1","first-page":"525","article-title":"Flexural and shear behavior of prestressed concrete beams using FRP rods as prestressing tendons","volume":"138","author":"Yonekura A","year":"1993","journal-title":"ACI Spec Publ"},{"key":"e_1_2_6_44_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)1090-0268(2003)7:4(275)"},{"key":"e_1_2_6_45_1","doi-asserted-by":"publisher","DOI":"10.15554\/pcij.06012011.94.112"},{"key":"e_1_2_6_46_1","unstructured":"ShapackG SeracinoR LucierG RizkallaS. Flexural behavior of cored slabs prestressed with carbon fiber strands. In: Proceedings of the 12th International Symposium on Fiber Reinforced Polymers for Reinforced Concrete Structures (FRPRCS\u201012).2015."},{"key":"e_1_2_6_47_1","doi-asserted-by":"publisher","DOI":"10.3390\/polym7101501"},{"key":"e_1_2_6_48_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)CC.1943-5614.0000421"},{"key":"e_1_2_6_49_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)CC.1943-5614.0000081"},{"key":"e_1_2_6_50_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-94-017-7336-2_7"},{"key":"e_1_2_6_51_1","doi-asserted-by":"publisher","DOI":"10.1016\/0263-8223(96)00045-1"},{"issue":"3","key":"e_1_2_6_52_1","first-page":"235","article-title":"Strengthening of concrete structures with prestressed FRP sheets","volume":"89","author":"Triantafillou TC","year":"1992","journal-title":"ACI Struct J"},{"key":"e_1_2_6_53_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)CC.1943-5614.0000372"},{"key":"e_1_2_6_54_1","doi-asserted-by":"publisher","DOI":"10.1002\/best.201400087"},{"key":"e_1_2_6_55_1","doi-asserted-by":"publisher","DOI":"10.1002\/bate.201400031"},{"key":"e_1_2_6_56_1","doi-asserted-by":"publisher","DOI":"10.1002\/bate.201200057"},{"key":"e_1_2_6_57_1","unstructured":"ZwingmannB SchlaichM LiuY. Research on using CFRP tension members in plane cable structures. Paper presented at: 7th International Conference on Fiber Reinforced Polymer (FRP) Composites in Civil Engineering (CICE 2014): Proceedings: 20\u201024.08.2014 Vancouver CANA."},{"key":"e_1_2_6_58_1","unstructured":"Kr\u00fcgerM.Vorgespannter textilbewehrter beton [Dissertation]. Stuttgart;2004."},{"key":"e_1_2_6_59_1","doi-asserted-by":"publisher","DOI":"10.1002\/best.200490119"},{"issue":"4","key":"e_1_2_6_60_1","first-page":"433","article-title":"Pretensioned prestressed concrete members with bonded fiber reinforced plastic tendons: Development and flexural bond lengths (static)","volume":"89","author":"Nanni A","year":"1992","journal-title":"ACI Struct J"},{"key":"e_1_2_6_61_1","doi-asserted-by":"publisher","DOI":"10.15554\/pcij.01011997.76.86"},{"issue":"3","key":"e_1_2_6_62_1","first-page":"281","article-title":"Bond properties of carbon fiber composite prestressing strands","volume":"95","author":"Domenico NG","year":"1998","journal-title":"ACI Struct J"},{"issue":"4","key":"e_1_2_6_63_1","first-page":"594","article-title":"Transfer and development lengths of carbon fiber reinforced polymers prestressing reinforcement","volume":"96","author":"Mahmoud Z","year":"1999","journal-title":"Struct J"},{"key":"e_1_2_6_64_1","doi-asserted-by":"publisher","DOI":"10.15554\/pcij.03012000.84.95"},{"key":"e_1_2_6_65_1","volume-title":"CFRP tendons in UHPFRC\u2013Bond behaviour and applications to folded and curved shells","author":"Stark A","year":"2013"},{"key":"e_1_2_6_66_1","unstructured":"KremS.Bond and flexural behaviour of self consolidating concrete beams reinforced and prestressed with FRP bars [Dissertation]. Waterloo Canada;2013."},{"key":"e_1_2_6_67_1","doi-asserted-by":"publisher","DOI":"10.1002\/best.201300038"},{"key":"e_1_2_6_68_1","unstructured":"NaamanAE JeongSM editors. Structural ductility of concrete beams prestressed with FRP tendons: Proceedings of the second international RILEM symposium (FRPRCS\u20102) Ghent 23\u201025 August 1995. 1st ed. London New York: E. & F.N. Spon;1995."},{"key":"e_1_2_6_69_1","doi-asserted-by":"publisher","DOI":"10.3390\/polym6061773"},{"issue":"6","key":"e_1_2_6_70_1","first-page":"25","article-title":"Ductility of prestressed bridges using CFRP strands","volume":"20","author":"Grace NF","year":"1998","journal-title":"Concr Int"},{"key":"e_1_2_6_71_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compositesb.2012.01.071"},{"key":"e_1_2_6_72_1","doi-asserted-by":"publisher","DOI":"10.1177\/0731684404033492"},{"key":"e_1_2_6_73_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)CC.1943-5614.0000355"},{"key":"e_1_2_6_74_1","unstructured":"JaegerL MuftiA TadrosG. The concept of the overall performance factor in rectangular\u2010section reinforced concrete beams. Proceedings of the 3rd International Symposium on Non\u2010Metallic (FRP) Reinforcement for Concrete Structures.1997:551\u2013558."},{"issue":"18","key":"e_1_2_6_75_1","first-page":"311","article-title":"Ductility in reinforced concrete: Why is it needed and how is it achieved","volume":"75","author":"Beeby A","year":"1997","journal-title":"Struct Eng"},{"key":"e_1_2_6_76_1","unstructured":"MoraisM.Ductility of beams prestressed with FRP tendons [Dissertation]. Cambridge UK;2005."},{"key":"e_1_2_6_77_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.conbuildmat.2010.11.040"},{"key":"e_1_2_6_78_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.conbuildmat.2013.02.065"},{"key":"e_1_2_6_79_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.engstruct.2011.02.014"},{"key":"e_1_2_6_80_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compositesb.2014.08.001"},{"key":"e_1_2_6_81_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cemconcomp.2007.04.011"},{"key":"e_1_2_6_82_1","unstructured":"L\u00e1russonLH. Development of flexible link slabs using ductile fiber reinforced concrete [Dissertation]. Lyngby Denmark;2013."},{"key":"e_1_2_6_83_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.compstruct.2012.03.007"},{"key":"e_1_2_6_84_1","first-page":"367","article-title":"Should FRP be bonded to concrete?","volume":"138","author":"Burgoyne CJ","year":"1993","journal-title":"ACI Spec Publ"},{"issue":"1","key":"e_1_2_6_85_1","first-page":"104","article-title":"Ductility demand of compression yielding fiber\u2010reinforced polymer\u2010reinforced concrete beams","volume":"105","author":"Wu Y\u2010F","year":"2008","journal-title":"Struct J"},{"key":"e_1_2_6_86_1","doi-asserted-by":"publisher","DOI":"10.1002\/stc.409"},{"key":"e_1_2_6_87_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.conbuildmat.2006.02.006"},{"issue":"2","key":"e_1_2_6_88_1","first-page":"143","article-title":"Relaxation, creep, and fatigue behavior of carbon fiber reinforced plastic tendons","volume":"96","author":"Saadatmanesh H","year":"1999","journal-title":"ACI Struct J"},{"key":"e_1_2_6_89_1","unstructured":"MertolHC RizkallaS ScottP LeesJM El\u2010HachaR. Durability of concrete beams prestressed with CFRP. ACI Special Publication 2007;254 \u201cCase histories and use of FRP for prestressing applications\u201d:21."},{"key":"e_1_2_6_90_1","doi-asserted-by":"crossref","unstructured":"TerrasiGP MeierU. Long term bending creep behaviour of thin\u2010walled CFRP pretensioned high strength spun concrete poles under sustained load. Paper presented at: 7th International Conference on Fiber Reinforced Polymer (FRP) Composites in Civil Engineering (CICE 2014): Proceedings: 2014 Aug 20\u201324 Vancouver CANA.","DOI":"10.3390\/polym6072065"},{"key":"e_1_2_6_91_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.conbuildmat.2006.06.008"},{"key":"e_1_2_6_92_1","unstructured":"MalukC BisbyLA TerrasiGP HugiE GreenM. Bond strength degradation for CFRP and steel reinforcing bars in concrete at elevated temperature. ACI Spec Publ 2011;297."},{"key":"e_1_2_6_93_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.conbuildmat.2015.10.031"},{"key":"e_1_2_6_94_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)CC.1943-5614.0000271"},{"key":"e_1_2_6_95_1","doi-asserted-by":"publisher","DOI":"10.1680\/macr.14.00367"},{"key":"e_1_2_6_96_1","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)1090-0268(2003)7:3(187)"},{"key":"e_1_2_6_97_1","volume-title":"Carbon fibre reinforced polymer (CFRP) cables for orthogonally loaded cable structures: Advantages and feasibility","author":"Liu Y","year":"2015"},{"key":"e_1_2_6_98_1","unstructured":"Canadian Standards Association. S806\u201012 Design and construction of building structures with fibre\u2010reinforced polymers(CAN\/CSA S806\u201012); 2012."},{"key":"e_1_2_6_99_1","unstructured":"JonnssonB.Prestressed BFRP tendons in concrete beams [Master Thesis]. Reykjavik Iceland;2011."},{"key":"e_1_2_6_100_1","doi-asserted-by":"publisher","DOI":"10.1680\/macr.11.00099"},{"key":"e_1_2_6_101_1","first-page":"27","article-title":"Marktpotenzial von Carbonbeton\u2013Prognosen zur Substitution von Stahl durch Carbon","volume":"13","author":"Tietze M","year":"2015","journal-title":"TUDALIT Mag"},{"key":"e_1_2_6_102_1","unstructured":"Transportation Research Division. Technical report 13\u201302: Post\u2010tensioned carbon fiber composite cable (CFCC) Little Pond Bridge Route 302 Fryeburg Maine; 2013."},{"key":"e_1_2_6_103_1","unstructured":"GraceNF JensenE EamonC EnomotoT ShiX. Life cycle cost analysis of prestressed concrete bridges using CFRP reinforcement. Paper presented at: Proceedings of CICE 2012 6th International Conference on FRP composites in Civil Engineering Rome Italy 2012 Jun 13\u201315."}],"container-title":["Structural Concrete"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/suco.201800347","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/suco.201800347","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/suco.201800347","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,10]],"date-time":"2023-09-10T17:05:15Z","timestamp":1694365515000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/suco.201800347"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3,28]]},"references-count":102,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019,6]]}},"alternative-id":["10.1002\/suco.201800347"],"URL":"https:\/\/doi.org\/10.1002\/suco.201800347","archive":["Portico"],"relation":{},"ISSN":["1464-4177","1751-7648"],"issn-type":[{"value":"1464-4177","type":"print"},{"value":"1751-7648","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3,28]]},"assertion":[{"value":"2018-12-10","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-02-15","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2019-03-28","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}