{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T15:01:21Z","timestamp":1787238081850,"version":"build-2736575974"},"reference-count":27,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2015,8,4]],"date-time":"2015-08-04T00:00:00Z","timestamp":1438646400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Energy Science &amp; Engineering"],"published-print":{"date-parts":[[2015,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    The University of Texas reported on a campaign to measure methane (\n                    <jats:styled-content style=\"fixed-case\">CH<\/jats:styled-content>\n                    <jats:sub>4<\/jats:sub>\n                    ) emissions from United States natural gas (\n                    <jats:styled-content style=\"fixed-case\">NG<\/jats:styled-content>\n                    ) production sites as part of an improved national inventory. Unfortunately, their study appears to have systematically underestimated emissions. They used the Bacharach Hi\u2010Flow\n                    <jats:sup>\u00ae<\/jats:sup>\n                    Sampler (\n                    <jats:styled-content style=\"fixed-case\">BHFS<\/jats:styled-content>\n                    ) which in previous studies has been shown to exhibit sensor failures leading to underreporting of\n                    <jats:styled-content style=\"fixed-case\">NG<\/jats:styled-content>\n                    emissions. The data reported by the University of Texas study suggest their measurements exhibit this sensor failure, as shown by the paucity of high\u2010emitting observations when the wellhead gas composition was less than 91%\n                    <jats:styled-content style=\"fixed-case\">CH<\/jats:styled-content>\n                    <jats:sub>4<\/jats:sub>\n                    , where sensor failures are most likely; during follow\u2010up testing, the\n                    <jats:styled-content style=\"fixed-case\">BHFS<\/jats:styled-content>\n                    used in that study indeed exhibited sensor failure consistent with under\u2010reporting of these high emitters. Tracer ratio measurements made by the University of Texas at a subset of sites with low\n                    <jats:styled-content style=\"fixed-case\">CH<\/jats:styled-content>\n                    <jats:sub>4<\/jats:sub>\n                    content further indicate that the\n                    <jats:styled-content style=\"fixed-case\">BHFS<\/jats:styled-content>\n                    measurements at these sites were too low by factors of three to five. Over 98% of the\n                    <jats:styled-content style=\"fixed-case\">CH<\/jats:styled-content>\n                    <jats:sub>4<\/jats:sub>\n                    inventory calculated from their own data and 41% of their compiled national inventory may be affected by this measurement failure. Their data also indicate that this sensor failure could occur at\n                    <jats:styled-content style=\"fixed-case\">NG<\/jats:styled-content>\n                    compositions as high as 97%\n                    <jats:styled-content style=\"fixed-case\">CH<\/jats:styled-content>\n                    <jats:sub>4<\/jats:sub>\n                    , possibly affecting other\n                    <jats:styled-content style=\"fixed-case\">BHFS<\/jats:styled-content>\n                    measurement programs throughout the entire\n                    <jats:styled-content style=\"fixed-case\">NG<\/jats:styled-content>\n                    supply chain, including at transmission sites where the\n                    <jats:styled-content style=\"fixed-case\">BHFS<\/jats:styled-content>\n                    is used to report greenhouse gas emissions to the United States Environmental Protection Agency Greenhouse Gas Reporting Program (\n                    <jats:styled-content style=\"fixed-case\">USEPA GHGRP<\/jats:styled-content>\n                    , U.S. 40\n                    <jats:styled-content style=\"fixed-case\">CFR<\/jats:styled-content>\n                    Part 98, Subpart W). The presence of such an obvious problem in this high profile, landmark study highlights the need for increased quality assurance in all greenhouse gas measurement programs.\n                  <\/jats:p>","DOI":"10.1002\/ese3.81","type":"journal-article","created":{"date-parts":[[2015,8,4]],"date-time":"2015-08-04T04:47:18Z","timestamp":1438663638000},"page":"443-455","source":"Crossref","is-referenced-by-count":23,"title":["University of Texas study underestimates national methane emissions at natural gas production sites due to instrument sensor failure"],"prefix":"10.1002","volume":"3","author":[{"given":"Touch\u00e9","family":"Howard","sequence":"first","affiliation":[{"name":"Indaco Air Quality Services, Inc.  Durham North Carolina"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2015,8,4]]},"reference":[{"key":"e_1_2_11_2_1","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.1304880110"},{"key":"e_1_2_11_3_1","doi-asserted-by":"publisher","DOI":"10.1021\/es5040156"},{"key":"e_1_2_11_4_1","doi-asserted-by":"publisher","DOI":"10.1021\/acs.est.5b00941"},{"key":"e_1_2_11_5_1","unstructured":"Bacharach Inc.2010.Hi\u2010Flow Sampler\u2122natural gas leak rate measurement. Instruction 0055\u20109017 Operation and Maintenance. Available at:http:\/\/www.bacharach-inc.com\/PDF\/Instructions\/55-9017.pdf(accessed 20 July 2015)."},{"key":"e_1_2_11_6_1","doi-asserted-by":"publisher","DOI":"10.1126\/science.1247045"},{"key":"e_1_2_11_7_1","unstructured":"Eastern Research Group (ERG).2011.City of Fort Worth natural gas air quality study final report Fort Worth TX. Available at:http:\/\/fortworthtexas.gov\/uploadedFiles\/Gas_Wells\/AirQualityStudy_final.pdf (accessed 20 July 2015)."},{"key":"e_1_2_11_8_1","unstructured":"Fox Thermal Instruments Inc.2015.Fox gas flow meter model FT2A instruction manual. Available at:http:\/\/www.foxthermalinstruments.com\/pdf\/ft2a\/FT2A_Manual.pdf(accessed 11 May 2015)."},{"key":"e_1_2_11_9_1","doi-asserted-by":"crossref","first-page":"1337","DOI":"10.1080\/10473289.1992.10467082","article-title":"Measurement of hydrocarbon emission fluxes from refinery wastewater impoundments using atmospheric tracer techniques","volume":"42","author":"Howard T.","year":"1992","journal-title":"J. Air Waste Manag. Assoc."},{"key":"e_1_2_11_10_1","unstructured":"Howard T. R.Kantamaneni andG.Jones.1999.Cost effective leak mitigation at natural gas compressor stations. Project No. RR\u2010246\u20109526 Catalog No. L51802.Pipeline Research Council International Arlington VA. Available at:http:\/\/prci.org(accessed 11 May 2015)."},{"key":"e_1_2_11_11_1","doi-asserted-by":"publisher","DOI":"10.1080\/10962247.2015.1025925"},{"key":"e_1_2_11_12_1","doi-asserted-by":"publisher","DOI":"10.1021\/acs.est.5b00507"},{"key":"e_1_2_11_13_1","doi-asserted-by":"publisher","DOI":"10.1002\/ese3.35"},{"key":"e_1_2_11_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10584\u2010011\u20100061\u20105"},{"key":"e_1_2_11_15_1","doi-asserted-by":"publisher","DOI":"10.1002\/grl.50811"},{"key":"e_1_2_11_16_1","doi-asserted-by":"publisher","DOI":"10.1021\/es505116p"},{"key":"e_1_2_11_17_1","doi-asserted-by":"publisher","DOI":"10.1021\/es00006a007"},{"key":"e_1_2_11_18_1","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.1314392110"},{"key":"e_1_2_11_19_1","unstructured":"Modrak M. T. M. S.Amin J.Ibanez C.Lehmann B.Harris D.Ranum et\u00a0al.2012.Understanding direct emission measurement approaches for upstream oil and gas production operations. Proceedings of the Air & Waste Management Association 105th Annual Conference & Exhibition San Antonio TX. Available at:http:\/\/portal.awma.org\/store\/detail.aspx?id&#x003D;411ACE12(accessed 20 July 2015)."},{"key":"e_1_2_11_20_1","first-page":"659","volume-title":"Climate change 2013: the physical science basis. Contribution of Working Group I to the Fifth Assessment Report of the Intergovernmental Panel on Climate Change","author":"Myhre G.","year":"2013"},{"key":"e_1_2_11_21_1","doi-asserted-by":"publisher","DOI":"10.1029\/2011JD016360"},{"key":"e_1_2_11_22_1","doi-asserted-by":"publisher","DOI":"10.1002\/2013JD021272"},{"key":"e_1_2_11_23_1","unstructured":"Prasino Group.2013.Final report for determining bleed rates for pneumatic devices in British Columbia. Report to British Columbia Ministry of Environment December 2013. Available at:http:\/\/www2.gov.bc.ca\/gov\/DownloadAsset?assetId=1F074ABD990D4EFB8AE555AEB3B8D771&filename=prasino_pneumatic_ghg_ef_final_report.pdf(accessed 11 May 2015)."},{"key":"e_1_2_11_24_1","unstructured":"United States Code of Federal Regulations.2014.40 CFR Part 98 subpart W. Available at:http:\/\/www.ecfr.gov\/cgi-bin\/text-idx?tpl=\/ecfrbrowse\/Title40\/40cfr98_main_02.tpl(accessed 11 May 2015)."},{"key":"e_1_2_11_25_1","unstructured":"United States Environmental Protection Agency (USEPA).1998.Inspection manual: federal equipment leak regulations for the chemical manufacturing industry. Volume III: petroleum refining industry regulations. EPA Office of Compliance: Chemical Commercial Services and Municipal Division. EPA\/305\/B\u201098\u2010011. Available at:http:\/\/www.epa.gov\/compliance\/resources\/publications\/assistance\/sectors\/insmanvol3.pdf(accessed 11 May 2015)."},{"key":"e_1_2_11_26_1","unstructured":"United States Environmental Protection Agency (USEPA).2003.Directed inspection and maintenance at compressor stations. EPA Natural Gas Star Program. Available at:http:\/\/www.epa.gov\/gasstar\/documents\/ll_dimcompstat.pdf(accessed 11 May 2015)."},{"key":"e_1_2_11_27_1","unstructured":"United States Environmental Protection Agency (USEPA).2014.Inventory of U.S. greenhouse gas emissions and sinks: 1990\u20132012. EPA 430\u2010R\u201014\u2010003. Available at:http:\/\/www.epa.gov\/climatechange\/emissions\/usinventoryreport.html(accessed 11 May 2015)."},{"key":"e_1_2_11_28_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10584-011-0217-3"}],"container-title":["Energy Science &amp; Engineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fese3.81","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ese3.81","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1002\/ese3.81","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/scijournals.onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ese3.81","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,15]],"date-time":"2025-10-15T11:51:19Z","timestamp":1760529079000},"score":1,"resource":{"primary":{"URL":"https:\/\/scijournals.onlinelibrary.wiley.com\/doi\/10.1002\/ese3.81"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,8,4]]},"references-count":27,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2015,9]]}},"alternative-id":["10.1002\/ese3.81"],"URL":"https:\/\/doi.org\/10.1002\/ese3.81","archive":["Portico"],"relation":{},"ISSN":["2050-0505","2050-0505"],"issn-type":[{"value":"2050-0505","type":"print"},{"value":"2050-0505","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,8,4]]}}}