{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T14:08:59Z","timestamp":1761919739323},"reference-count":20,"publisher":"Wiley","issue":"2","license":[{"start":{"date-parts":[[2011,6,1]],"date-time":"2011-06-01T00:00:00Z","timestamp":1306886400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Structural Concrete"],"published-print":{"date-parts":[[2011,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Currently, long\u2010term monitoring systems are mandatory for major civil engineering structures such as bridges, tunnels and dams. Generally, they monitor a set of physical, chemical and mechanical parameters in critical sections of the structure by incorporating appropriate sensors. The set of data collected demonstrates great potential in the prevention of damage and contributes to more efficient maintenance of the structures monitored. This work presents the long\u2010term monitoring system installed on the new Lez\u00edria Bridge over the River Tagus in Portugal. The system was developed to control some aspects of the construction process and to survey the service life of the structure. A set of structural, durability and environmental parameters defining the bridge condition are remotely assessed in real\u2010time via a fibreoptic network. Aspects such as architecture, installation and functionality of the monitoring system are discussed and the innovative aspects of the implementation are highlighted. In this context, the main goal of this work is to present the long\u2010term monitoring system of Lez\u00edria Bridge, sharing the experiences, the solutions and the procedures adopted, given their potential usefulness in the implementation of similar projects.<\/jats:p>","DOI":"10.1002\/suco.201000014","type":"journal-article","created":{"date-parts":[[2013,10,15]],"date-time":"2013-10-15T08:20:41Z","timestamp":1381825241000},"page":"82-93","source":"Crossref","is-referenced-by-count":25,"title":["Design and implementation of a monitoring system applied to a long\u2010span prestressed concrete bridge"],"prefix":"10.1002","volume":"12","author":[{"given":"Helder","family":"Sousa","sequence":"first","affiliation":[]},{"given":"Carlos","family":"F\u00e9lix","sequence":"additional","affiliation":[]},{"given":"Jo\u00e3o","family":"Bento","sequence":"additional","affiliation":[]},{"given":"Joaquim","family":"Figueiras","sequence":"additional","affiliation":[]}],"member":"311","published-online":{"date-parts":[[2011,6]]},"reference":[{"key":"e_1_2_1_2_2","doi-asserted-by":"publisher","DOI":"10.1177\/147592103039836"},{"key":"e_1_2_1_3_2","doi-asserted-by":"publisher","DOI":"10.1061\/(ASCE)0742-597X(2006)22:4(186)"},{"key":"e_1_2_1_4_2","doi-asserted-by":"publisher","DOI":"10.1680\/stco.2002.3.1.29"},{"key":"e_1_2_1_5_2","doi-asserted-by":"publisher","DOI":"10.1080\/15732470601130378"},{"key":"e_1_2_1_6_2","doi-asserted-by":"publisher","DOI":"10.1002\/pse.129"},{"key":"e_1_2_1_7_2","doi-asserted-by":"publisher","DOI":"10.1680\/stco.2001.2.1.29"},{"key":"e_1_2_1_8_2","unstructured":"BRITE\/EURAM SMART STRUCTURES \u2013 Integrated Monitoring Systems for Durability Assessment of Concrete Structures Online. Project No. BRPR\u2010CT98\u20100751 1997. Available from: http:\/\/smart.ramboll.dk\/smart_eu\/index.htm [accessed October 2008]."},{"key":"e_1_2_1_9_2","doi-asserted-by":"publisher","DOI":"10.1080\/15732470600591117"},{"key":"e_1_2_1_10_2","unstructured":"Oliveira C. B.: New crossing of the Tagus river from Carregado to Lez\u00edria through A10. Ingenium No. 95 2006 (in Portuguese)."},{"key":"e_1_2_1_11_2","unstructured":"COBA\u2010PC & A\u2010CIVILSER\u2010ARCADIS \u2013 Construction of the Tagus Crossing in Carregado Subsection A1\/Benavente of A10 Highway Bucelas\/Carregado\/IC3; Volume XV \u2013 Structural and Durability Monitoring Plan. Contract of Conception Design and Construction of Crossing the Tagus in Carregado Portugal 2006 (in Portuguese)."},{"key":"e_1_2_1_12_2","unstructured":"Figueiras J. et al.: Construction of the Tagus Crossing in Carregado Subsection A1\/Benavente of A10 Highway Bucelas\/Carregado\/IC3; Structural and Durability Monitoring Executive Project 0 \u2013 Presentation. LABEST Faculty of Engineering University of Porto 2007 (in Portuguese)."},{"key":"e_1_2_1_13_2","unstructured":"Figueiras J. et al.: Construction of the Tagus Crossing in Carregado Subsection A1\/Benavente of A10 Highway Bucelas\/Carregado\/IC3; Structural and Durability Monitoring Executive Project A \u2013 Project Brief. LABEST Faculty of Engineering University of Porto 2007 (in Portuguese)."},{"key":"e_1_2_1_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0958-9465(96)00040-6"},{"key":"e_1_2_1_15_2","unstructured":"Inaudi D.: (1999) Long\u2010gage fibre optic sensors for structural monitoring. InP. K. Rastogi(ed.) Optical Measurement Techniques and Applications. Artech House 1997 pp. 255\u2013275."},{"key":"e_1_2_1_16_2","doi-asserted-by":"publisher","DOI":"10.1177\/1475921703002002004"},{"key":"e_1_2_1_17_2","unstructured":"Rodrigues C. F\u00e9lix C. Figueiras J.: \u201cFiber Optic Strain Transducer \u2013 Conception analysis and calibration.\u201d Internal Report LABEST Faculty of Engineering University of Porto 2007 (in Portuguese)."},{"key":"e_1_2_1_18_2","unstructured":"Figueiras J. et al.: Construction of the Tagus Crossing in Carregado Subsection A1\/Benavente of A10 Highway Bucelas\/Carregado\/IC3; Structural and Durability Monitoring Executive Project G \u2013 Operations Manual. LABEST Faculty of Engineering University of Porto 2007 (in Portuguese)."},{"key":"e_1_2_1_19_2","unstructured":"Figueiras J. et al.: Construction of the Tagus Crossing in Carregado Subsection A1\/Benavente of A10 Highway Bucelas\/Carregado\/IC3; Structural and Durability Monitoring Executive Project B \u2013 Contract Drawings. LABEST Faculty of Engineering University of Porto 2007 (in Portuguese)."},{"key":"e_1_2_1_20_2","unstructured":"Figueiras J. et al.: Construction of the Tagus Crossing in Carregado Subsection A1\/Benavente of A10 Highway Bucelas\/Carregado\/IC3; Structural and Durability Monitoring Executive Project C \u2013 Specifications and Procedures. LABEST Faculty of Engineering University of Porto 2007 (in Portuguese)."},{"key":"e_1_2_1_21_2","unstructured":"Rudaz S. et al.: AC\u201023\u2010DH Downhole Accelerometer \u2013 Installation Instructions \u2013 Version 1 online. GeoSIG Ldt. 2006. Available from: http:\/\/www.geosig.com\/downloads\/manuals\/AC\u201023\u2010DH_Installation_Instructions.pdf [accessed 16 September 2008]."}],"container-title":["Structural Concrete"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1002%2Fsuco.201000014","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/suco.201000014","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,20]],"date-time":"2023-11-20T14:54:24Z","timestamp":1700492064000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1002\/suco.201000014"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,6]]},"references-count":20,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2011,6]]}},"alternative-id":["10.1002\/suco.201000014"],"URL":"https:\/\/doi.org\/10.1002\/suco.201000014","archive":["Portico"],"relation":{},"ISSN":["1464-4177","1751-7648"],"issn-type":[{"value":"1464-4177","type":"print"},{"value":"1751-7648","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,6]]}}}