{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,4]],"date-time":"2024-09-04T17:19:34Z","timestamp":1725470374768},"publisher-location":"Berlin, Heidelberg","reference-count":9,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783540665038"},{"type":"electronic","value":"9783540482321"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[1999]]},"DOI":"10.1007\/10704282_29","type":"book-chapter","created":{"date-parts":[[2006,9,9]],"date-time":"2006-09-09T06:22:22Z","timestamp":1157782942000},"page":"263-270","source":"Crossref","is-referenced-by-count":0,"title":["Automatic Classification of Linear Structures in Mammographic Images"],"prefix":"10.1007","author":[{"given":"Reyer","family":"Zwiggelaar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher J.","family":"Taylor","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Caroline R. M.","family":"Boggis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"issue":"1","key":"29_CR1","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/S1361-8415(99)80016-4","volume":"3","author":"R. Zwiggelaar","year":"1999","unstructured":"Zwiggelaar, R., Parr, T.C., Schumm, J.E., Hutt, I.W., Astley, S.M., Taylor, C.J., Boggis, C.R.M.: Model-based detection of spiculated lesions in mammograms. Medical Image Analysis\u00a03(1), 39\u201362 (1999)","journal-title":"Medical Image Analysis"},{"key":"29_CR2","doi-asserted-by":"crossref","unstructured":"Astley, S.M., Zwiggelaar, R., Wolstenholme, C., Taylor, C.J.: Prompting in mammography: how accurate must prompt generators be? In: 4th International Workshop on Digital Mammography, Nijmegen, The Netherlands, pp. 347\u2013354 (1998)","DOI":"10.1007\/978-94-011-5318-8_56"},{"issue":"10","key":"29_CR3","doi-asserted-by":"publisher","first-page":"1102","DOI":"10.1097\/00004424-199010000-00006","volume":"25","author":"H.-P. Chan","year":"1990","unstructured":"Chan, H.-P., Doi, K., Vyborny, C.J., Schmidt, R.A., Metz, C.E., Lam, K.L., Ogura, T., Wu, Y., MacMahon, H.: Improvement in radiologists\u2019 detection of clustered microcalcifications on mammograms. Investigative Radiology\u00a025(10), 1102\u20131110 (1990)","journal-title":"Investigative Radiology"},{"key":"29_CR4","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1148\/radiology.191.2.8153302","volume":"191","author":"W.P. Kegelmeyer","year":"1994","unstructured":"Kegelmeyer, W.P., Pruneda, J., Bourland, P., Hills, A., Riggs, M., Nipper, M.: Computer-aided mammographic screening for spiculated lesions. Radiology\u00a0191, 331\u2013337 (1994)","journal-title":"Radiology"},{"issue":"5","key":"29_CR5","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1109\/42.538938","volume":"15","author":"N. Karssemeijer","year":"1996","unstructured":"Karssemeijer, N., te Brake, G.M.: Detection of stellate distortions in mammograms. IEEE Transactions on Medical Imaging\u00a015(5), 611\u2013619 (1996)","journal-title":"IEEE Transactions on Medical Imaging"},{"key":"29_CR6","volume-title":"The Mammographic Teaching Atlas","author":"L. Tabar","year":"1985","unstructured":"Tabar, L., Dean, P.B.: The Mammographic Teaching Atlas. Georg Thieme Verlag, Stuttgart (1985)"},{"issue":"2","key":"29_CR7","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1118\/1.597465","volume":"22","author":"T. Ema","year":"1995","unstructured":"Ema, T., Doi, K., Nishikawa, R.M., Jiang, Y., Papaioannou, J.: Image feature analysis and computer-aided diagnosis in mammography: reduction of false-positive clustered microcalcifications using local edge-gradient analysis. Medical Physics\u00a022(2), 161\u2013169 (1995)","journal-title":"Medical Physics"},{"key":"29_CR8","doi-asserted-by":"crossref","unstructured":"Zwiggelaar, R., Parr, T.C., Taylor, C.J.: Finding orientated line patterns in digital mammographic images. In: Proceedings of the 7th British Machine Vision Conference, Edinburgh, UK, pp. 715\u2013724 (1996)","DOI":"10.5244\/C.10.70"},{"key":"29_CR9","first-page":"375","volume-title":"Digital Mammography","author":"J. Suckling","year":"1994","unstructured":"Suckling, J., Parker, J., Dance, D., Astley, S., Hutt, I., Boggis, C., Ricketts, I., Stamatakis, E., Cerneaz, N., Kok, S., Taylor, P., Betal, D., Savage, J.: The mammographic images analysis society digital mammogram database. In: Gale, D. (ed.) Digital Mammography, pp. 375\u2013378. Elsevier, Amsterdam (1994)"}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI\u201999"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/10704282_29","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,3,23]],"date-time":"2019-03-23T06:38:29Z","timestamp":1553323109000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/10704282_29"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1999]]},"ISBN":["9783540665038","9783540482321"],"references-count":9,"URL":"https:\/\/doi.org\/10.1007\/10704282_29","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[1999]]}}}