{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,5]],"date-time":"2024-09-05T15:27:58Z","timestamp":1725550078943},"publisher-location":"Berlin, Heidelberg","reference-count":15,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783540293279"},{"type":"electronic","value":"9783540320944"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2005]]},"DOI":"10.1007\/11566465_111","type":"book-chapter","created":{"date-parts":[[2005,9,27]],"date-time":"2005-09-27T13:18:15Z","timestamp":1127827095000},"page":"902-909","source":"Crossref","is-referenced-by-count":0,"title":["Kinematic Geometry of Osteotomies"],"prefix":"10.1007","author":[{"given":"Erin J.","family":"Smith","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J. Tim","family":"Bryant","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Randy E.","family":"Ellis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"111_CR1","volume-title":"Campbell\u2019s Operative Orthopaedics","year":"2003","unstructured":"Canale, S.T. (ed.): Campbell\u2019s Operative Orthopaedics, 10th edn. Mosby Inc., Philadelphia (2003)","edition":"10"},{"key":"111_CR2","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1302\/0301-620X.76B1.8300662","volume":"76","author":"R. Bilic","year":"1994","unstructured":"Bilic, R., Zdravkovic, V., Boljevic, Z.: Osteotomy for deformity of the radius: Computer-assisted three-dimensional modelling. Journal of Bone and Joint Surgery\u00a076, 150\u2013154 (1994)","journal-title":"Journal of Bone and Joint Surgery"},{"key":"111_CR3","unstructured":"Moctezuma, J.L., Goss\u00e9, F., Schulz, H.J.: A computer and robot aided surgery system for accomplishing osteotomies. In: International Symposium on Medical Robotics and Computer Assist ed Surgery, pp. 31\u201335 (1994)"},{"key":"111_CR4","first-page":"4","volume":"15","author":"E.Y.S. Chao","year":"1995","unstructured":"Chao, E.Y.S., Sim, F.H.: Computer-aided preoperative planning in knee osteotomy. Iowa Orthopaedic Journal\u00a015, 4\u201318 (1995)","journal-title":"Iowa Orthopaedic Journal"},{"key":"111_CR5","doi-asserted-by":"publisher","first-page":"264","DOI":"10.3109\/10929089909148179","volume":"4","author":"R.E. Ellis","year":"1999","unstructured":"Ellis, R.E., Tso, C.Y., Rudan, J.F., Harrison, M.M.: A surgical planning and guidance system for high tibial osteotomy. Computer Aided Surgery\u00a04, 264\u2013274 (1999)","journal-title":"Computer Aided Surgery"},{"key":"111_CR6","doi-asserted-by":"publisher","first-page":"160","DOI":"10.3109\/10929080109146002","volume":"6","author":"H. Croitoru","year":"2001","unstructured":"Croitoru, H., Ellis, R.E., Small, C.F., Prihar, R., Pichora, D.R.: Fixation-based surgery: A new technique for distal radius osteotomy. Computer Aided Surgery\u00a06, 160\u2013169 (2001)","journal-title":"Computer Aided Surgery"},{"key":"111_CR7","doi-asserted-by":"publisher","first-page":"179","DOI":"10.3109\/10929080209146028","volume":"7","author":"D. Mayman","year":"2002","unstructured":"Mayman, D., Rudan, J.F., Yach, J., Ellis, R.E.: The Kingston periacetabular osteotomy: A new computer-enhanced technique. Computer Aided Surgery\u00a07, 179\u2013186 (2002)","journal-title":"Computer Aided Surgery"},{"key":"111_CR8","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1016\/S0363-5023(03)00375-7","volume":"28","author":"G.S. Athwal","year":"2003","unstructured":"Athwal, G.S., Ellis, R.E., Small, C.F., Pichora, D.R.: Outcomes of computer-assisted distal radius osteotomy. Journal of Hand Surgery\u00a028, 951\u2013958 (2003)","journal-title":"Journal of Hand Surgery"},{"key":"111_CR9","volume-title":"Introduction to Robotics: Mechanics and Control","author":"J.J. Craig","year":"1989","unstructured":"Craig, J.J.: Introduction to Robotics: Mechanics and Control. Addison-Wesley, Reading (1989)"},{"key":"111_CR10","first-page":"271","volume":"78","author":"R.M. d\u2019Aubigne","year":"1952","unstructured":"d\u2019Aubigne, R.M., Descamps, L.: L\u2019osteotomie plane oblique dans la correction des deformations des membres. Memoires: Academie de Chirurgie\u00a078, 271\u2013276 (1952)","journal-title":"Memoires: Academie de Chirurgie"},{"key":"111_CR11","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1016\/j.clinbiomech.2004.09.017","volume":"20","author":"D. Meyer","year":"2005","unstructured":"Meyer, D., Siebenrock, K., Schiele, B., Gerber, C.: A new methodology for the planning of single-cut corrective osteotomies of mal-aligned bones. Clinical Biomechanics\u00a020, 223\u2013227 (2005)","journal-title":"Clinical Biomechanics"},{"key":"111_CR12","volume-title":"An Introduction to Theoretical Kinematics","author":"J.M. McCarthy","year":"1990","unstructured":"McCarthy, J.M.: An Introduction to Theoretical Kinematics. MIT Press, Cambridge (1990)"},{"volume-title":"Kinematic Geometry of Mechanisms","year":"1990","key":"111_CR13","unstructured":"Hunt, K.H. (ed.): Kinematic Geometry of Mechanisms. Oxforn University Press, New York (1990)"},{"key":"111_CR14","doi-asserted-by":"publisher","first-page":"1271","DOI":"10.1016\/0021-9290(89)90230-3","volume":"22","author":"B.P. Sangeorzan","year":"1989","unstructured":"Sangeorzan, B.P., Judd, R., Sangeorzan, B.J.: Mathematical analysis of single-cut osteotomy for complex long bone deformity. Journal of Biomechanics\u00a022, 1271\u20131278 (1989)","journal-title":"Journal of Biomechanics"},{"key":"111_CR15","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1097\/00005131-198912000-00001","volume":"3","author":"B.P. Sangeorzan","year":"1989","unstructured":"Sangeorzan, B.P., Sangeorzan, B.J., Hansen, S., Judd, R.: Mathematically directed single-cut osteotomy for correction of tibial malunion. Journal of Orthopaedic Trauma\u00a03, 267\u2013275 (1989)","journal-title":"Journal of Orthopaedic Trauma"}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2005"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/11566465_111.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,27]],"date-time":"2021-04-27T07:16:06Z","timestamp":1619507766000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/11566465_111"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005]]},"ISBN":["9783540293279","9783540320944"],"references-count":15,"URL":"https:\/\/doi.org\/10.1007\/11566465_111","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2005]]}}}