{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T18:26:25Z","timestamp":1776277585477,"version":"3.50.1"},"publisher-location":"Berlin, Heidelberg","reference-count":13,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"value":"9783540293262","type":"print"},{"value":"9783540320951","type":"electronic"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2005]]},"DOI":"10.1007\/11566489_102","type":"book-chapter","created":{"date-parts":[[2005,9,27]],"date-time":"2005-09-27T13:27:44Z","timestamp":1127827664000},"page":"830-837","source":"Crossref","is-referenced-by-count":5,"title":["CT Hepatic Venography: 3D Vascular Segmentation for Preoperative Evaluation"],"prefix":"10.1007","author":[{"given":"Catalin","family":"Fetita","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Olivier","family":"Lucidarme","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fran\u00e7oise","family":"Pr\u00eateux","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philippe","family":"Grenier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"102_CR1","first-page":"1065","volume":"183","author":"Y. Onodera","year":"2004","unstructured":"Onodera, Y., et al.: Peripheral anatomic evaluation using 3D CT hepatic venography in donors: significance of peripheral venous visualization in living-donor transplantation. American Journal of Radiology\u00a0183, 1065\u20131070 (2004)","journal-title":"American Journal of Radiology"},{"key":"102_CR2","first-page":"331","volume-title":"Matematica et Cultura 2000","author":"H.-O. Peitgen","year":"2000","unstructured":"Peitgen, H.-O., et al.: Risk analysis for liver surgery. In: Emmer, M. (ed.) Matematica et Cultura 2000, pp. 331\u2013340. Springer, Milano (2000)"},{"issue":"11","key":"102_CR3","doi-asserted-by":"publisher","first-page":"1344","DOI":"10.1109\/TMI.2002.801166","volume":"21","author":"D. Selle","year":"2002","unstructured":"Selle, D., et al.: Analysis of vasculature for liver surgical planning. IEEE Trans. Med. Imaging\u00a021(11), 1344\u20131357 (2002)","journal-title":"IEEE Trans. Med. Imaging"},{"key":"102_CR4","doi-asserted-by":"crossref","unstructured":"Reitinger, B., Bornik, A., Beichel, R., Werkgartner, G., Sorantin, E.: Tools for Augmented Reality based Liver Resection Planning. In: SPIE Medical Imaging 2004, pp. 88\u201399 (2004)","DOI":"10.1117\/12.535545"},{"key":"102_CR5","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1016\/S0097-8493(02)00102-4","volume":"26","author":"H.-P. Meinzer","year":"2002","unstructured":"Meinzer, H.-P., Thorn, M., Cardenas, C.: Computerized planning of liver surgery - an overview. Computers & Graphics\u00a026, 569\u2013576 (2002)","journal-title":"Computers & Graphics"},{"key":"102_CR6","doi-asserted-by":"crossref","unstructured":"Bourquain, H., et al.: HepaVision2 - A software assistant for preoperative planning in living-related liver transplantation and oncologic liver surgery. In: Proc. CARS 2002, pp. 341\u2013346 (2002)","DOI":"10.1007\/978-3-642-56168-9_56"},{"key":"102_CR7","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1007\/10704282_11","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI\u201999","author":"P. Dokladal","year":"1999","unstructured":"Dokladal, P., Lohou, C., Perroton, L., Bertrand, G.: Liver blood vessel extraction by a 3D topological approach. In: Taylor, C., Colchester, A. (eds.) MICCAI 1999. LNCS, vol.\u00a01679, pp. 98\u2013105. Springer, Heidelberg (1999)"},{"key":"102_CR8","doi-asserted-by":"crossref","unstructured":"Fishman, E.K., Kuszyk, B.S., Heath, D.G., Gao, L., Cabral, B.: Surgical planning for liver resection. IEEE Computer, 64\u201372 (1996)","DOI":"10.1109\/2.481467"},{"issue":"3","key":"102_CR9","doi-asserted-by":"publisher","first-page":"131","DOI":"10.3109\/10929080109145999","volume":"6","author":"L. Soler","year":"2001","unstructured":"Soler, L., et al.: Fully automatic anatomical, pathological, and functional segmentation from CT scans for hepatic surgery. Computer Aided Surgery\u00a06(3), 131\u2013142 (2001)","journal-title":"Computer Aided Surgery"},{"issue":"11","key":"102_CR10","doi-asserted-by":"publisher","first-page":"1353","DOI":"10.1109\/TMI.2004.826945","volume":"23","author":"C. Fetita","year":"2004","unstructured":"Fetita, C., Preteux, F., Beigelman-Aubry, C., Grenier, P.: Pulmonary airways: 3D reconstruction from multi-slice CT and clinical investigation. IEEE Transactions on Medical Imaging\u00a023(11), 1353\u20131364 (2004)","journal-title":"IEEE Transactions on Medical Imaging"},{"issue":"2","key":"102_CR11","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1109\/83.217222","volume":"2","author":"L. Vincent","year":"1993","unstructured":"Vincent, L.: Morphological gray scale reconstruction in image analysis: applications and efficient algorithms. IEEE Trans on Image Processing\u00a02(2), 176\u2013201 (1993)","journal-title":"IEEE Trans on Image Processing"},{"key":"102_CR12","unstructured":"Pr\u00eateux, F.: On a distance function approach for gray-level mathematical morphology. In: Dekker, M. (ed.) Mathematical morphology in image processing, E.R. Dougherty (1992)"},{"issue":"3-4","key":"102_CR13","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1002\/cav.40","volume":"15","author":"D. Perchet","year":"2004","unstructured":"Perchet, D., Fetita, C., Vial, L., Preteux, F., Caillibotte, G., Sbirlea-Apiou, G., Thiriet, M.: Virtual investigation of pulmonary airways in volumetric computed tomography. Computer Animation & Virtual Worlds\u00a015(3-4), 361\u2013376 (2004)","journal-title":"Computer Animation & Virtual Worlds"}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2005"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/11566489_102.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,27]],"date-time":"2021-04-27T06:38:38Z","timestamp":1619505518000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/11566489_102"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005]]},"ISBN":["9783540293262","9783540320951"],"references-count":13,"URL":"https:\/\/doi.org\/10.1007\/11566489_102","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"value":"0302-9743","type":"print"},{"value":"1611-3349","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005]]}}}