{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,7]],"date-time":"2026-02-07T22:24:12Z","timestamp":1770503052500,"version":"3.49.0"},"publisher-location":"Berlin, Heidelberg","reference-count":25,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"value":"9783540005506","type":"print"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"DOI":"10.1007\/3-540-36460-9_31","type":"book-chapter","created":{"date-parts":[[2007,8,11]],"date-time":"2007-08-11T04:42:02Z","timestamp":1186807322000},"page":"467-483","source":"Crossref","is-referenced-by-count":22,"title":["Analysis of Robotic Locomotion Devices for the Gastrointestinal Tract"],"prefix":"10.1007","author":[{"given":"L.","family":"Phee","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Menciassi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Accoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Stefanini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"Dario","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","reference":[{"key":"31_CR1","unstructured":"Accoto D, Stefanini C, Phee L, Arena A, Pernorio G, Menciassi A, Carrozza M, Dario P (2001) Measurements of the friction properties of the gastrointestinal tract. In 2nd AIMETA International Tribology Conference, Vienna."},{"key":"31_CR2","first-page":"779","volume-title":"Medicine and Medical Robot. and Computer Assisted Surgery","author":"M.C. Carrozza","year":"1997","unstructured":"Carrozza MC, Lencioni L, Magnani B, D\u2019Attanasio S, Dario P (1997) The development of a microrobot system for colonoscopy. In Proc. First Joint Conf. of Computer Vision, Virtual Reality and Robot, vol 1205 of Medicine and Medical Robot. and Computer Assisted Surgery, pp 779\u2013788. Springer-Verlag, Berlin-Heidelberg."},{"key":"31_CR3","volume-title":"Practical gastrointestinal endoscopy","author":"P.B. Cotton","year":"1990","unstructured":"Cotton PB, Williams CB (1990) Practical gastrointestinal endoscopy. Blackwell Scientific Publications, Oxford."},{"key":"31_CR4","doi-asserted-by":"crossref","unstructured":"Dario P, Carrozza MC, Lencioni L, Magnani B, D\u2019Attanasio S (1997) A micro robotic system for colonoscopy. In Proc. 1997 IEEE Int. Conf. Robot. Automat., pp 1567\u20131572, Albuquerque, NM.","DOI":"10.1109\/ROBOT.1997.614363"},{"key":"31_CR5","first-page":"4","volume":"4","author":"P. Dario","year":"1999","unstructured":"Dario P, Carrozza MC, Pietrabissa A (1999a) Development and in vitro tests of a miniature robotic system for computer assisted colonoscopy. Journal of Computer Aided Surgery, 4: 4\u201314.","journal-title":"Journal of Computer Aided Surgery"},{"key":"31_CR6","unstructured":"Dario P, Carrozza MC, Pietrabissa A, Magnani B, Lencioni L (1999b) Endoscopic robot. United States Patent, Patent Number 5,906,591."},{"key":"31_CR7","volume-title":"Physiology of the digestive tract","author":"W. Davenport","year":"1982","unstructured":"Davenport W (1982) Physiology of the digestive tract. Year Book Medical Pub., Chicago."},{"issue":"1","key":"31_CR8","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1088\/0964-1726\/6\/1\/003","volume":"6","author":"S. A. Della","year":"1997","unstructured":"Della Santa A, Mazzoldi A, De Rossi D (1997) Characterisation and modelling of a conducting polymer muscle-like actuators. Smart Mater. Struct., 6(1):23\u201334.","journal-title":"Smart Mater. Struct."},{"key":"31_CR9","doi-asserted-by":"crossref","unstructured":"Fukuda T, Hosokai H, Uemura M (1989) Rubber gas actuator driven by hydrogen storage alloy for in-pipe inspection mobile robot with flexible structure. In Proc. 1989 IEEE Int. Conf. Robot. Automat., pp 1847\u20131852, Scottsdale, AZ.","DOI":"10.1109\/ROBOT.1989.100242"},{"key":"31_CR10","doi-asserted-by":"crossref","DOI":"10.1007\/978-1-4419-6856-2","volume-title":"Biomechanics: Motion, flow, stress and growth","author":"Y.C. Fung","year":"1990","unstructured":"Fung YC (1990) Biomechanics: Motion, flow, stress and growth. Springer-Verlag, New York."},{"key":"31_CR11","unstructured":"Gisela L, Miller MM, Tang WC, Raz S (2000) Improved sensor pills for physiological monitoring. Nasa Tech Brief from JPL New Tech report NPO-20652, 25(2)."},{"key":"31_CR12","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1111\/j.1365-2982.1996.tb00267.x","volume":"8","author":"H. Gregersen","year":"1996","unstructured":"Gregersen H, Kassab G (1996) Biomechanics of the gastrointestinal tract. Neurogastroen-terol. Mot., 8:277\u2013297.","journal-title":"Neurogastroen-terol. Mot."},{"key":"31_CR13","unstructured":"Grundfest WS, Burdick JW, Slatkin AB (1997) Robotic endoscopy. United States Patent, Patent Number 5,662,587."},{"key":"31_CR14","volume-title":"Biologically inspired robots: Snake-like locomotors and manipulators","author":"S. Hirose","year":"1993","unstructured":"Hirose S, Cave P, Goulden C (1993) Biologically inspired robots: Snake-like locomotors and manipulators. Oxford University Press, New York."},{"key":"31_CR15","doi-asserted-by":"crossref","unstructured":"Hoeg HD, Slatkin AB, Burdick JW, Grundfest WS (2000) Biomechanical modelling of the small intestine as required for the design and operation of a robotic endoscope. In Proc. 2000 IEEE Int. Conf. Robot. Automat., pp 1599\u20131606, San Francisco, CA.","DOI":"10.1109\/ROBOT.2000.844825"},{"issue":"6785","key":"31_CR16","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1038\/35013140","volume":"405","author":"G. Iddan","year":"2000","unstructured":"Iddan G, Meron G, Glukhovsky A, Swain P (2000) Wireless capsule endoscopy. Nature, 405 (6785):417.","journal-title":"Nature"},{"key":"31_CR17","doi-asserted-by":"crossref","unstructured":"Ikuta K, Tsukamoto M, Hirose S (1988) Shape memory alloy servo actuator system with electric resistence feedback and application for active endoscope. In Proc. 1988 IEEE Int. Conf. Robot. Automat., pp 427\u2013430, Philadelphia, Pennsylvania.","DOI":"10.1109\/ROBOT.1988.12085"},{"key":"31_CR18","unstructured":"Ng WS, Phee SJ, Seow-Choen F (2000) Robotic endoscope and an autonomous pipe robot for performing endoscopic procedures. United States Patent, Patent Number 6,162,171."},{"issue":"2","key":"31_CR19","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1021\/ma00080a025","volume":"27","author":"H. Okuzaki","year":"1994","unstructured":"Okuzaki H, Osada Y (1994) Effects of hydrophobic interaction on the cooperative binding of a surfactant to a polymer network. Macromolecules, 27(2):502\u2013506.","journal-title":"Macromolecules"},{"key":"31_CR20","unstructured":"Phee SJ, Ng WS, Chen IM, Seow-Choen F (1997a) Development of new locomotive concepts to be used in automation of colonoscopy. In 9th Int. Conf. for BioMedical Engineering, pp 87\u201392, Singapore."},{"key":"31_CR21","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1109\/51.637122","volume":"16","author":"S.J. Phee","year":"1997","unstructured":"Phee SJ, Ng WS, Chen IM, Seow-Choen F, Davies BL (1997b) Locomotion and steering aspects in automation of colonoscopy. IEEE Engineering in Medicine and Biology Magazine, 16(6):85\u201396.","journal-title":"IEEE Engineering in Medicine and Biology Magazine"},{"key":"31_CR22","first-page":"89","volume":"20","author":"M. Shahinpoor","year":"1996","unstructured":"Shahinpoor M (1996) Ionic polymeric gels as artificial muscles for robotic and medical applications. Int. Journal Sci. Technol., 20:89\u2013136. Transaction B.","journal-title":"Int. Journal Sci. Technol."},{"key":"31_CR23","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1007\/BFb0035207","volume-title":"Experimental Robotics IV, The 4th Int. Symp.","author":"A.B. Slatkin","year":"1997","unstructured":"Slatkin AB, Burdick J, Grundfest W (1997) The development of a robotic endoscope. In Experimental Robotics IV, The 4th Int. Symp., pp 161\u2013169, Berlin. Springer-Verlag."},{"key":"31_CR24","unstructured":"Treat MR, Trimmer WS (1997) Self-propelled endoscope using pressure driven linear actuators. United States Patent, Patent Number 5,595,565."},{"key":"31_CR25","volume-title":"Modern batteries","author":"C.A. Vincent","year":"1998","unstructured":"Vincent CA (1998) Modern batteries. Edward Arnold Pub., London, U.K., 2nd edition.","edition":"2nd edition"}],"container-title":["Springer Tracts in Advanced Robotics","Robotics Research"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/3-540-36460-9_31.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,20]],"date-time":"2025-01-20T07:56:22Z","timestamp":1737359782000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/3-540-36460-9_31"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[null]]},"ISBN":["9783540005506"],"references-count":25,"URL":"https:\/\/doi.org\/10.1007\/3-540-36460-9_31","relation":{},"subject":[]}}