{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T05:47:08Z","timestamp":1794376028492,"version":"4.9.0"},"publisher-location":"Berlin, Heidelberg","reference-count":26,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"value":"9783540426974","type":"print"},{"value":"9783540454687","type":"electronic"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2001]]},"DOI":"10.1007\/3-540-45468-3_64","type":"book-chapter","created":{"date-parts":[[2010,3,29]],"date-time":"2010-03-29T17:13:08Z","timestamp":1269882788000},"page":"532-540","source":"Crossref","is-referenced-by-count":11,"title":["Geometrical Transformation Approximation for 2D\/3D Intensity-Based Registration of Portal Images and CT Scan"],"prefix":"10.1007","author":[{"given":"David","family":"Sarrut","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S\u00e9bastien","family":"Clippe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2001,10,5]]},"reference":[{"issue":"2","key":"64_CR1","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/S0360-3016(99)00200-X","volume":"45","author":"C. Carrie","year":"1999","unstructured":"C. Carrie, S. Hoffstetter, and F. Gomez et al. Impact of targeting deviations on outcome in medulloblastoma: study of the french society of pediatric oncology (SFOP). Int. J. Radiat. Oncol. Biol. Phys., 45(2):435\u20139, September 1999.","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"issue":"1","key":"64_CR2","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1016\/S0360-3016(99)00140-6","volume":"45","author":"U. Mock","year":"1999","unstructured":"U. Mock, K. Dieckmann, U. Wol., T.H. Knocke, and R. Potter. Portal imaging based definition of the planning target volume during pelvici irradiation for gynecological malignancies. Int. J. Radiat. Oncol. Biol. Phys., 45(1):227\u2013232, 1999.","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"issue":"2","key":"64_CR3","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1016\/S0360-3016(99)00386-7","volume":"46","author":"J.C. Stroom","year":"2000","unstructured":"J.C. Stroom, M.J. Olofsen van Acht, and S. Quint et al. On-line set-up corrections during radiotherapy of patients with gynecologic tumors. Int. J. Radiat. Oncol. Biol. Phys., 46(2):499\u2013506, 2000.","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"issue":"1","key":"64_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0167-8140(99)00181-4","volume":"54","author":"C.M. Nutting","year":"2000","unstructured":"C.M. Nutting, V.S. Khoo, V. Walker, H. McNair, C. Beardmore, A. Norman, and D.P. Dearnaley. A randomized study of the use of a customized immobilization system in the treatment of prostate cancer with conformal radiotherapy. Radiother. Oncol., 54(1):1\u20139, 2000.","journal-title":"Radiother. Oncol."},{"issue":"2","key":"64_CR5","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/S1053-4296(95)80005-0","volume":"5","author":"P. Munro","year":"1995","unstructured":"P. Munro. Portal imaging technology: past, present, and future. Sem. Radiat. Oncol., 5(2):115\u2013133, 1995.","journal-title":"Sem. Radiat. Oncol."},{"key":"64_CR6","series-title":"Lect Notes Comput Sci","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1007\/10704282_84","volume-title":"MICCAI\u201999","author":"G. Ionescu","year":"1999","unstructured":"G. Ionescu, S. Lavalle, and J. Demongeot. Automated registration of ultrasound with ct images: Application to computer assisted prostate radiotherapy and orthopedics. In MICCAI\u201999, volume 1679 of LNCS, pages 768\u2013777, Cambridge, England, September 1999."},{"issue":"12","key":"64_CR7","doi-asserted-by":"publisher","first-page":"1665","DOI":"10.1088\/0031-9155\/36\/12\/010","volume":"36","author":"J. Bijhold","year":"1991","unstructured":"J. Bijhold, M. van Herk, R. Vijlbrief, and J.V. Lebesque. Fast evaluation of patient set-up during radiotherapy by aligning features in portal and simulator images. Phys. Med. Biol., 36(12):1665\u201379, 1991.","journal-title":"Phys. Med. Biol."},{"issue":"4","key":"64_CR8","doi-asserted-by":"publisher","first-page":"967","DOI":"10.1016\/S0360-3016(97)00925-5","volume":"40","author":"J. Steene Van de","year":"1998","unstructured":"J. Van de Steene, F. Van den Heuvel, and A. Bel et al. Electronic portal imaging with on-line correction of setup error in thoracic irradiation: clinical evaluation. Int. J. Radiat. Oncol. Biol. Phys., 40(4):967\u2013976, 1998.","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"issue":"4","key":"64_CR9","doi-asserted-by":"publisher","first-page":"1145","DOI":"10.1118\/1.596968","volume":"20","author":"K.L. Lam","year":"1993","unstructured":"K.L. Lam, R.K. Ten Haken, McShan DL, and Thornton AF Jr. Automated determination of patient setup errors in radiation therapy using spherical radioopaque markers. Med Phys, 20(4):1145\u201352, 1993.","journal-title":"Med Phys"},{"issue":"4","key":"64_CR10","doi-asserted-by":"publisher","first-page":"1153","DOI":"10.1118\/1.596969","volume":"20","author":"K.P. Gall","year":"1993","unstructured":"K.P. Gall, L.J. Verhey, and M. Wagner. Computer-assisted positioning of radiotherapy patients using implanted radiopaque fiducials. Med. Phys., 20(4):1153\u20139, 1993.","journal-title":"Med. Phys."},{"issue":"4","key":"64_CR11","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1109\/34.385980","volume":"17","author":"S. Lavall\u00e9e","year":"1995","unstructured":"S. Lavall\u00e9e and R. Szeliski. Recovering the Position and Orientation of Free-Form Objects from Image Contours Using 3D Distance Maps. IEEE Transactions on Pattern Analysis and Machine Intelligence, 17(4):378\u2013390, April 1995.","journal-title":"IEEE Transactions on Pattern Analysis and Machine Intelligence"},{"issue":"4","key":"64_CR12","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1016\/0360-3016(95)02183-3","volume":"34","author":"K.G. Gilhuijs","year":"1996","unstructured":"K.G. Gilhuijs, K. Drukker, A. Touw, P.J. van de Ven, and M. van Herk. Interactive three dimensional inspection of patient setup in radiation therapy using digital portal images and computed tomography data. Int. J. Radiat. Oncol. Biol. Phys., 34(4):873\u201385, 1996.","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"issue":"5","key":"64_CR13","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1016\/S0360-3016(99)00468-X","volume":"46","author":"P. Remeijer","year":"2000","unstructured":"P. Remeijer, E. Geerlof, L. Ploeger, K. Gilhuijs, M. van Herk, and J.V. Lebesque. 3-D portal image analysis in clinical practice: an evaluation of 2-D and 3-D analysis techniques as applied to 30 prostate cancer patients. Int. J. Radiat. Oncol. Biol. Phys., 46(5):1281\u201390, 2000.","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"64_CR14","unstructured":"D. Plattard, G. Champleboux, P. Vassal, J. Troccaz, and M. Bolla. EPID for patient positioning in radiotherapy: calibration and image matching in the entroPID system. In H.U. Lemke, editor, CARS\u201999, pages 265\u20139. Elsevier science, 1999."},{"issue":"6","key":"64_CR15","doi-asserted-by":"publisher","first-page":"287","DOI":"10.3109\/10929089909148182","volume":"4","author":"R. Bansal","year":"1999","unstructured":"R. Bansal, L. Staib, Z. Chen, A. Rangarajan, J. Knisely, R. Nath R, and J. Duncan. A minimax entropy registration framework for patient setup verification in radiotherapy. Computer Aided Surgery, 4(6):287\u2013304, 1999.","journal-title":"Computer Aided Surgery"},{"key":"64_CR16","unstructured":"R. Goecke, J. Weese, and H. Schumann. Fast volume rendering methods for voxelbased 2d\/3d registration\u2013a comparative study. In International Workshop on Biomedical Image Registration, pages 89\u2013102, Bled, Slovenia, August 1999."},{"key":"64_CR17","unstructured":"D. Sarrut and S. Clippe. Patient positioning in radiotherapy by registration of 2D portal to 3D CT images by a contend-based research with similarity measures. In Computer Assisted Radiology and Surgery, pages p 707\u2013712, San Fransisco, USA, June 2000. Elsevier Science."},{"issue":"5","key":"64_CR18","doi-asserted-by":"publisher","first-page":"1331","DOI":"10.1016\/0360-3016(95)02062-4","volume":"33","author":"J. Hanley","year":"1995","unstructured":"J. Hanley, G.S. Mageras, J. Sun, and G.J. Kutcher. The effects of out-of-plane rotations on two dimensional portal image registration in conformal radiotherapy of the prostate. Int. J. Radiat. Oncol. Biol. Phys., 33(5):1331\u20131343, 1995.","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"64_CR19","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1109\/42.730403","volume":"17","author":"G.P. Penney","year":"1998","unstructured":"G.P. Penney, J. Weese, J.A. Little, P. Desmedt, D.L.G. Hill, and D.J. Hawkes. A comparison of similarity measures for use in 2D-3D medical image registration. IEEE Transaction on Medical Imaging, 17:586\u2013595, 1998.","journal-title":"IEEE Transaction on Medical Imaging"},{"key":"64_CR20","unstructured":"W.H. Press, B.P. Flannery, S.A. Teukolsky, and W.T. Vetterling. Numerical Recipes in C: The Art of Scientific Computing. Cambridge University Press, second edition, 1992."},{"issue":"1","key":"64_CR21","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1118\/1.597743","volume":"23","author":"D.H. Hristov","year":"1996","unstructured":"D.H. Hristov and B.G. Fallone. A grey-level image alignment algorithm for registration of portal images and digitally reconstructed radiographs. Med Phys, 23(1):75\u201384, 1996.","journal-title":"Med Phys"},{"issue":"2","key":"64_CR22","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1109\/42.563664","volume":"16","author":"F. Maes","year":"1997","unstructured":"F. Maes, A. Collignon, D. Vandermeulen, G. Marchal, and P. Suetens. Multimodality Image Registration by Maximization of Mutual Information. IEEE Transaction On Medical Imaging, 16(2):187\u2013198, April 1997.","journal-title":"IEEE Transaction On Medical Imaging"},{"issue":"1","key":"64_CR23","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/S1361-8415(01)80004-9","volume":"1","author":"W.M. Wells","year":"1996","unstructured":"W.M. Wells, P.A. Viola, H. Atsumi, S. Nakajima, and R. Kikinis. Multi-Modal Volume Registration by Maximization of Mutual Information. Medical Image Analysis, 1(1):35\u201351, 1996.","journal-title":"Medical Image Analysis"},{"key":"64_CR24","doi-asserted-by":"crossref","unstructured":"A. Roche, G. Malandain, X. Pennec, and N. Ayache. The Correlation Ratio as a New Similarity Measure for Multimodal Image Registration. In MICCAI\u201998, pages 1115\u20131124, Cambridge Massachusetts (USA), October 1998.","DOI":"10.1007\/BFb0056301"},{"key":"64_CR25","unstructured":"D. Sarrut. Recalage multimodal et plate-forme d\u2019imagerie m\u00e9dicale \u00e0 acc\u00e8s distant. PhD thesis, Universit\u00e9 Lumi\u00e8re Lyon 2, January 2000. In french."},{"issue":"5","key":"64_CR26","doi-asserted-by":"publisher","first-page":"1053","DOI":"10.1016\/0360-3016(95)02082-9","volume":"33","author":"L. Dong","year":"1995","unstructured":"L. Dong and A.L. Boyer. An image correlation procedure for digitally reconstructed radiographs and electronic portal images. Int. J. Radiat. Oncol. Biol. Phys., 33(5):1053\u201360, 1995.","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2001"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/3-540-45468-3_64","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,2,23]],"date-time":"2019-02-23T20:39:38Z","timestamp":1550954378000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/3-540-45468-3_64"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001]]},"ISBN":["9783540426974","9783540454687"],"references-count":26,"URL":"https:\/\/doi.org\/10.1007\/3-540-45468-3_64","relation":{"is-part-of":[{"id-type":"doi","id":"https:\/\/doi.org\/10.1007\/3-540-45468-3","asserted-by":"object"}]},"ISSN":["0302-9743"],"issn-type":[{"value":"0302-9743","type":"print"}],"subject":[],"published":{"date-parts":[[2001]]}}}