{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,12]],"date-time":"2025-04-12T05:47:56Z","timestamp":1744436876027},"publisher-location":"Berlin, Heidelberg","reference-count":9,"publisher":"Springer Berlin Heidelberg","isbn-type":[{"type":"print","value":"9783540442257"},{"type":"electronic","value":"9783540457879"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2002]]},"DOI":"10.1007\/3-540-45787-9_65","type":"book-chapter","created":{"date-parts":[[2007,5,3]],"date-time":"2007-05-03T21:36:55Z","timestamp":1178228215000},"page":"517-524","source":"Crossref","is-referenced-by-count":19,"title":["A Comparison of 2D-3D Intensity-Based Registration and Feature-Based Registration for Neurointerventions"],"prefix":"10.1007","author":[{"given":"Robert A.","family":"McLaughlin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Hipwell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David J.","family":"Hawkes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.Alison","family":"Noble","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James V.","family":"Byrne","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tim","family":"Cox","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2002,10,10]]},"reference":[{"key":"65_CR1","doi-asserted-by":"crossref","unstructured":"Chung, A.C.S., Noble, J.A.: Statistical 3D vessel segmentation using a Rician distribution. In: Proc. MICCAI. (1999) 82\u201389","DOI":"10.1007\/10704282_9"},{"key":"65_CR2","unstructured":"Chung, A., Noble, J.: Fusing magnitude and phase information for vascular segmentation in phase contrast mr angiograms. In: Proc. MICCAI. (2000) 166\u2013175"},{"key":"65_CR3","doi-asserted-by":"publisher","first-page":"586","DOI":"10.1109\/42.730403","volume":"17","author":"G.P. Penney","year":"1998","unstructured":"Penney, G.P., Weese, J., Little, J.A., Desmedt, P., Hill, D.L.G., Hawkes, D.J.: A comparison of similarity measures for use in 2d-3d medical image registration. IEEE Transactions on Medical Imaging 17 (1998) 586\u2013595","journal-title":"IEEE Transactions on Medical Imaging"},{"key":"65_CR4","unstructured":"Kita, Y., Wilson, D.L., Noble, J.A.: Real-time registration of 3D cerebral vessels to X-ray angiograms. In: MICCAI\u201998. (1998) 1125\u20131133"},{"key":"65_CR5","volume-title":"Phd thesis","author":"G.P. Penney","year":"2000","unstructured":"Penney, G.P.: Registration of Tomographic Images to X-ray Projections for Use in Image Guided Interventions. Phd thesis, University College London, CISG, Division of Radiological Sciences, Guy\u2019s Hospital, King\u2019s College London, London SE1 9RT England (2000)"},{"key":"65_CR6","doi-asserted-by":"crossref","unstructured":"Heuring, J.J., Murray, D.W.: Visual head tracking and slaving for visual telepresence. In: Proc. of IEEE Int. Conf. on Robotics and Automation. (1996) 2908\u20132914","DOI":"10.1109\/ROBOT.1996.509154"},{"key":"65_CR7","unstructured":"McLaughlin, R.A., Hipwell, J., Penney, G.P., Rhode, K., Chung, A., Noble, J.A., Hawkes, D.J.: Intensity-based registration versus feature-based registration for neurointerventions. In: Proceedings of Medical Image Understanding and Analysis (MIUA). (2001) 69\u201372"},{"key":"65_CR8","unstructured":"Masutani, Y., Dohi, T., et al., F.Y.: Interactive virtualized display system for intravascular neurosurgery. In: CVRMed-MRCAS\u201997. (1997) 427\u2013435"},{"key":"65_CR9","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1145\/358669.358692","volume":"24","author":"M.A. Fischler","year":"1981","unstructured":"Fischler, M.A., Bolles, R.C.: Random sample consensus: A paradigm for model fitting with applications to image analysis and automated cartography. Communications of the ACM 24 (1981) 381\u2013395","journal-title":"Communications of the ACM"}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer-Assisted Intervention \u2014 MICCAI 2002"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/3-540-45787-9_65","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,2,16]],"date-time":"2019-02-16T08:27:24Z","timestamp":1550305644000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/3-540-45787-9_65"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002]]},"ISBN":["9783540442257","9783540457879"],"references-count":9,"URL":"https:\/\/doi.org\/10.1007\/3-540-45787-9_65","relation":{},"ISSN":["0302-9743"],"issn-type":[{"type":"print","value":"0302-9743"}],"subject":[],"published":{"date-parts":[[2002]]}}}