{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,27]],"date-time":"2025-03-27T10:53:03Z","timestamp":1743072783666,"version":"3.40.3"},"publisher-location":"New York, NY","reference-count":59,"publisher":"Springer New York","isbn-type":[{"type":"print","value":"9781461484943"},{"type":"electronic","value":"9781461484950"}],"license":[{"start":{"date-parts":[[2013,1,1]],"date-time":"2013-01-01T00:00:00Z","timestamp":1356998400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2013,1,1]],"date-time":"2013-01-01T00:00:00Z","timestamp":1356998400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013]]},"DOI":"10.1007\/978-1-4614-8495-0_22","type":"book-chapter","created":{"date-parts":[[2013,11,20]],"date-time":"2013-11-20T06:07:50Z","timestamp":1384927670000},"page":"481-502","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Wearable and Implantable Technologies for Cardiovascular Health Informatics"],"prefix":"10.1007","author":[{"given":"Yali","family":"Zheng","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carmen C. Y.","family":"Poon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuan Ting","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2013,11,21]]},"reference":[{"key":"22_CR1","unstructured":"S. S. Hu, L. Z. Kong, R. L. Gao, M. L. Zhu, W. Wang, Y. J. Wang, Z. S. Wu, W. W. Chen, and M. B. Liu, \u201cOutline of the Report on Cardiovascular Disease in China, 2010,\u201d Biomedical and Environmental Sciences, Vol. 25, No. 3, 2012, pp. 251\u2013256."},{"key":"22_CR2","unstructured":"D. E. Bloom, E. T. Cafiero, E. Jan\u00e9-Llopis, S. Abrahams-Gessel, L. R. Bloom, S. Fathima, A. B. Feigl, T. Gaziano, M. Mowafi, A. Pandya, K. Prettner, L. Rosenberg, B. Seligman, A. Z. Stein, C. Weinstein, The Global Economic Burden of Non-Communicable Diseases: Geneva: World, Economic Forum, 2011."},{"key":"22_CR3","doi-asserted-by":"crossref","unstructured":"H. Baek, G. Chung, K. Kim, and K. Park, \u201cA Smart Health Monitoring Chair for Nonintrusive Measurement of Biological Signals,\u201d IEEE Transactions on Information Technology in Biomedicine, Vol. 16, No. 1, 2012, pp. 150\u2013158.","DOI":"10.1109\/TITB.2011.2175742"},{"key":"22_CR4","unstructured":"K. F. Wu, C. H. Chan, Y. T. Zhang, \u201cContactless and Cuffless Monitoring of Blood Pressure on a Chair Using E-Textile Materials,\u201d in 3rd IEEE\/EMBS International Summer School on Medical Devices and, Biosensors, 2006."},{"key":"22_CR5","doi-asserted-by":"crossref","unstructured":"J. Y. Baek, J. H. An, J. M. Choi, K. S. Park, and S. H. Lee, \u201cFlexible Polymeric Dry Electrodes for the Long-Term Monitoring of Ecg,\u201d Sensors and Actuators a-Physical, Vol. 143, No. 2, May 2008, pp. 423\u2013429.","DOI":"10.1016\/j.sna.2007.11.019"},{"key":"22_CR6","doi-asserted-by":"crossref","unstructured":"J. Yoo, Y. Long, L. Seulki, K. Hyejung, and Y. Hoi-Jun, \u201cA Wearable Ecg Acquisition System with Compact Planar-Fashionable Circuit Board-Based Shirt,\u201d IEEE Transactions on Information Technology in Biomedicine, Vol. 13, No. 6, 2009, pp. 897\u2013902.","DOI":"10.1109\/TITB.2009.2033053"},{"key":"22_CR7","doi-asserted-by":"crossref","unstructured":"T. H. Kang, C. R. Merritt, E. Grant, B. Pourdeyhimi, and H. T. Nagle, \u201cNonwoven Fabric Active Electrodes for Biopotential Measurement During Normal Daily Activity,\u201d IEEE Transactions on Biomedical Engineering, Vol. 55, No. 1, Jan 2008, pp. 188\u2013195.","DOI":"10.1109\/TBME.2007.910678"},{"key":"22_CR8","doi-asserted-by":"crossref","unstructured":"A. John, \u201cPhotoplethysmography and Its Application in Clinical Physiological Measurement,\u201d Physiological Measurement, Vol. 28, No. 3, 2007, p. R1.","DOI":"10.1088\/0967-3334\/28\/3\/R01"},{"key":"22_CR9","doi-asserted-by":"crossref","unstructured":"R. G. Haahr, S. B. Duun, M. H. Toft, B. Belhage, J. Larsen, K. Birkelund, and E. V. Thomsen, \u201cAn Electronic Patch for Wearable Health Monitoring by Reflectance Pulse Oximetry,\u201d IEEE Transactions on Biomedical Circuits and Systems, Vol. 6, No. 1, Feb 2012, pp. 45\u201353.","DOI":"10.1109\/TBCAS.2011.2164247"},{"key":"22_CR10","doi-asserted-by":"crossref","unstructured":"C. C. Y. Poon and Y. T. Zhang, \u201cCuff-Less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time,\u201d in 27th Annual International Conference of the IEEE Engineering in Medicine and Biology Society 2005.","DOI":"10.1109\/IEMBS.2005.1615827"},{"key":"22_CR11","doi-asserted-by":"crossref","unstructured":"L. Wang, C. C. Y. Poon, and Y. T. Zhang, \u201cThe Non-Invasive and Continuous Estimation of Cardiac Output Using a Photoplethysmogram and Electrocardiogram During Incremental Exercise,\u201d Physiological Measurement, Vol. 31, 2010, p. 715.","DOI":"10.1088\/0967-3334\/31\/5\/008"},{"key":"22_CR12","unstructured":"Y. L. Zheng, B. Leung, S. Sy, Y. T. Zhang, and C. C. Y. Poon, \u201cA Clip-Free Eyeglasses-Based Wearable Monitoring Device for Measuring Photoplethysmograhic Signals,\u201d in 27th Annual International Conference of the IEEE-EMBS, 2012."},{"key":"22_CR13","doi-asserted-by":"crossref","unstructured":"S. B. Duun, R. G. Haahr, K. Birkelund, and E. V. Thomsen, \u201cA Ring-Shaped Photodiode Designed for Use in a Reflectance Pulse Oximetry Sensor in Wireless Health Monitoring Applications,\u201d IEEE Sensors Journal, Vol. 10, No. 2, 2010, pp. 261\u2013268.","DOI":"10.1109\/JSEN.2009.2032925"},{"key":"22_CR14","doi-asserted-by":"crossref","unstructured":"M. Y. M. Wong, E. Pickwell-MacPherson, and Y. T. Zhang, \u201cThe Acute Effects of Running on Blood Pressure Estimation Using Pulse Transit Time in Normotensive Subjects,\u201d European Journal of Applied Physiology, Vol. 107, No. 2, 2009, pp. 169\u2013175.","DOI":"10.1007\/s00421-009-1112-8"},{"key":"22_CR15","doi-asserted-by":"crossref","unstructured":"Y. Chen, C. Wen, G. Tao, M. Bi, and G. Li, \u201cContinuous and Noninvasive Blood Pressure Measurement: A Novel Modeling Methodology of the Relationship between Blood Pressure and Pulse Wave Velocity,\u201d Annals of Biomedical Engineering, Vol. 37, No. 11, 2009, pp. 2222\u20132233.","DOI":"10.1007\/s10439-009-9759-1"},{"key":"22_CR16","doi-asserted-by":"crossref","unstructured":"J. Muehlsteff, X. L. Aubert, and M. Schuett, \u201cCuffless Estimation of Systolic Blood Pressure for Short Effort Bicycle Tests: The Prominent Role of the Pre-Ejection Period,\u201d in 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2006.","DOI":"10.1109\/IEMBS.2006.260275"},{"key":"22_CR17","doi-asserted-by":"crossref","unstructured":"Z. B. Zhang, Y. H. Shen, W. D. Wang, B. Q. Wang, and J. W. Zheng, \u201cDesign and Implementation of Sensing Shirt for Ambulatory Cardiopulmonary Monitoring,\u201d Journal of Medical and Biological Engineering, Vol. 31, No. 3, 2011, pp. 207\u2013215.","DOI":"10.5405\/jmbe.801"},{"key":"22_CR18","doi-asserted-by":"crossref","unstructured":"T. Hoffmann, B. Eilebrecht, and S. Leonhardt, \u201cRespiratory Monitoring System on the Basis of Capacitive Textile Force Sensors,\u201d IEEE Sensors Journal, Vol. 11, No. 5, 2011, pp. 1112\u20131119.","DOI":"10.1109\/JSEN.2010.2082524"},{"key":"22_CR19","doi-asserted-by":"crossref","unstructured":"C. C. Y. Poon, W. B. Gu, and Y. T. Zhang, \u201cHealth Informatics for Low-Cost and High-Quality Health Care,\u201d in 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2010.","DOI":"10.1109\/IEMBS.2010.5626726"},{"key":"22_CR20","doi-asserted-by":"crossref","unstructured":"M. Z. Poh, N. C. Swenson, and R. W. Picard, \u201cMotion-Tolerant Magnetic Earring Sensor and Wireless Earpiece for Wearable Photoplethysmography,\u201d IEEE Transactions on Information Technology in Biomedicine, Vol. 14, No. 3, 2010, pp. 786\u2013794.","DOI":"10.1109\/TITB.2010.2042607"},{"key":"22_CR21","doi-asserted-by":"crossref","unstructured":"U. Anliker, J. A. Ward, P. Lukowicz, G. Troster, F. Dolveck, M. Baer, F. Keita, E. B. Schenker, F. Catarsi, L. Coluccini, A. Belardinelli, D. Shklarski, M. Alon, E. Hirt, R. Schmid, and M. Vuskovic, \u201cAmon: A Wearable Multiparameter Medical Monitoring and Alert System,\u201d IEEE Transactions on Information Technology in Biomedicine, Vol. 8, No. 4, 2004, pp. 415\u2013427.","DOI":"10.1109\/TITB.2004.837888"},{"key":"22_CR22","doi-asserted-by":"crossref","unstructured":"M. Rothmaier, B. Selm, S. Spichtig, D. Haensse, and M. Wolf, \u201cPhotonic Textiles for Pulse Oximetry,\u201d Optics Express, Vol. 16, No. 17, Aug 2008, pp. 12973\u201312986.","DOI":"10.1364\/OE.16.012973"},{"key":"22_CR23","doi-asserted-by":"crossref","unstructured":"G. Z. Liu, B. Y. Huang, and L. Wang, \u201cA Wearable Respiratory Biofeedback System Based on Generalized Body Sensor Network,\u201d Telemedicine and e-Health, Vol. 17, No. 5, 2011, pp. 348\u2013357.","DOI":"10.1089\/tmj.2010.0182"},{"key":"22_CR24","doi-asserted-by":"crossref","unstructured":"C. C. Y. Poon, Y. M. Wong, Y. T. Zhang, \u201cM-Health: The Development of Cuff-Less and Wearable Blood Pressure Meters for Use in Body Sensor Networks,\u201d presented at the IEEE\/NLM Life Science Systems and Applications, Workshop, 2006.","DOI":"10.1109\/LSSA.2006.250377"},{"key":"22_CR25","doi-asserted-by":"crossref","unstructured":"Y. T. Zhang, C. C. Y. Poon, C. H. Chan, M. W. W. Tsang, K. F. Wu, \u201cA Health-Shirt Using E-Textile Materials for the Continuous and Cuffless Monitoring of Arterial Blood Pressure,\u201d in 3rd IEEE\/EMBS International Summer School on Medical Devices and, Biosensors, 2006.","DOI":"10.1109\/ISSMDBS.2006.360104"},{"key":"22_CR26","doi-asserted-by":"crossref","unstructured":"C. W. Mundt, K. N. Montgomery, U. E. Udoh, V. N. Barker, G. C. Thonier, A. M. Tellier, R. D. Ricks, R. B. Darling, Y. D. Cagle, N. A. Cabrol, S. J. Ruoss, J. L. Swain, J. W. Hines, and G. T. A. Kovacs, \u201cA Multiparameter Wearable Physiologic Monitoring System for Space and Terrestrial Applications,\u201d IEEE Transactions on Information Technology in Biomedicine, Vol. 9, No. 3, Sep 2005, pp. 382\u2013391.","DOI":"10.1109\/TITB.2005.854509"},{"key":"22_CR27","doi-asserted-by":"crossref","unstructured":"P. Castiglioni, A. Faini, G. Parati, and M. Di Rienzo, \u201cWearable Seismocardiography,\u201d in 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2007.","DOI":"10.1109\/IEMBS.2007.4353199"},{"key":"22_CR28","doi-asserted-by":"crossref","unstructured":"Y. Chuo and B. Kaminska, \u201cSensor Layer of a Multiparameter Single-Point Integrated System,\u201d IEEE Transactions on Biomedical Circuits and Systems, Vol. 3, No. 4, 2009, pp. 229\u2013240.","DOI":"10.1109\/TBCAS.2009.2021769"},{"key":"22_CR29","doi-asserted-by":"crossref","unstructured":"Y. Chuo, M. Marzencki, B. Hung, C. Jaggernauth, K. Tavakolian, P. Lin, and B. Kaminska, \u201cMechanically Flexible Wireless Multisensor Platform for Human Physical Activity and Vitals Monitoring,\u201d IEEE Transactions on Biomedical Circuits and Systems, Vol. 4, No. 5, Oct 2010, pp. 281\u2013294.","DOI":"10.1109\/TBCAS.2010.2052616"},{"key":"22_CR30","unstructured":"W. P. S. McKay, P. H. Gregson, B. W. S. McKay, and J. Militzer, \u201cSternal Acceleration Ballistocardiography and Arterial Pressure Wave Analysis to Determine Stroke Volume,\u201d Clinical and Investigative Medicine, Vol. 22, 1999, pp. 4\u201314."},{"key":"22_CR31","doi-asserted-by":"crossref","unstructured":"S. Coyle, K. T. Lau, N. Moyna, D. O\u2019Gorman, D. Diamond, F. Di Francesco, D. Costanzo, P. Salvo, M. G. Trivella, D. E. De Rossi, N. Taccini, R. Paradiso, J. A. Porchet, A. Ridolfi, J. Luprano, C. Chuzel, T. Lanier, F. Revol-Cavalier, S. Schoumacker, V. Mourier, I. Chartier, R. Convert, H. De-Moncuit, and C. Bini, \u201cBiotex-Biosensing Textiles for Personalised Healthcare Management,\u201d IEEE Transactions on Information Technology in Biomedicine, Vol. 14, No. 2, Mar 2010, pp. 364\u2013370.","DOI":"10.1109\/TITB.2009.2038484"},{"key":"22_CR32","doi-asserted-by":"crossref","unstructured":"D. H. Kim, N. Lu, R. Ma, Y. S. Kim, R. H. Kim, S. Wang, J. Wu, S. M. Won, H. Tao, A. Islam, K. J. Yu, T.-i. Kim, R. Chowdhury, M. Ying, L. Z. Xu, M. Li, H. J. Chung, H. Keum, M. McCormick, P. Liu, Y. W. Zhang, F. G. Omenetto, Y. G. Huang, T. Coleman, and J. A. Rogers, \u201cEpidermal Electronics,\u201d Science, Vol. 333, No. 6044, August 12, 2011 2011, pp. 838\u2013843.","DOI":"10.1126\/science.1206157"},{"key":"22_CR33","doi-asserted-by":"crossref","unstructured":"L. Beckmann, C. Neuhaus, G. Medrano, N. Jungbecker, M. Walter, T. Gries, and S. Leonhardt, \u201cCharacterization of Textile Electrodes and Conductors Using Standardized Measurement Setups,\u201d Physiological Measurement, Vol. 31, 2010, pp. 233\u2013247.","DOI":"10.1088\/0967-3334\/31\/2\/009"},{"key":"22_CR34","doi-asserted-by":"crossref","unstructured":"X. F. Teng and Y. T. Zhang, \u201cTheoretical Study on the Effect of Sensor Contact Force on Pulse Transit Time,\u201d IEEE Transactions on Biomedical Engineering, Vol. 54, No. 8, 2007, pp. 1490\u20131498.","DOI":"10.1109\/TBME.2007.900815"},{"key":"22_CR35","doi-asserted-by":"crossref","unstructured":"S. Yoon, S. Min, Y. Yun, S. Lee, and M. Lee, \u201cAdaptive Motion Artifacts Reduction Using 3-Axis Accelerometer in E-Textile Ecg Measurement System,\u201d Journal of Medical Systems, Vol. 32, No. 2, 2008, pp. 101\u2013106.","DOI":"10.1007\/s10916-007-9112-x"},{"key":"22_CR36","doi-asserted-by":"crossref","unstructured":"J. Kim, M. S. Chae, and W. Liu, \u201cA 220nw Neural Amplifier for Multi-Channel Neural Recording Systems,\u201d in IEEE International Symposium on Circuits and Systems, 2009.","DOI":"10.1109\/ISCAS.2009.5117991"},{"key":"22_CR37","unstructured":"E. Villegas, \u201cA Low-Power Wide Range Transimpedance Amplifier for Biochemical Sensing,\u201d in 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2007."},{"key":"22_CR38","doi-asserted-by":"crossref","unstructured":"R. Rieger and S. H. Nian, \u201cIntegrated Control Circuit for Adaptive Sampling,\u201d Analog Integrated Circuits and Signal Processing, Vol. 72, No. 1, Jul 2012, pp. 227\u2013235.","DOI":"10.1007\/s10470-011-9817-0"},{"key":"22_CR39","doi-asserted-by":"crossref","unstructured":"M. Lee, C. Y. Chen, S. Wang, S. N. Cha, Y. J. Park, J. M. Kim, L. J. Chou, and Z. L. Wang, \u201cA Hybrid Piezoelectric Structure for Wearable Nanogenerators,\u201d Advanced Materials, Vol. 24, No. 13, Apr 2012, pp. 1759\u20131764.","DOI":"10.1002\/adma.201200150"},{"key":"22_CR40","doi-asserted-by":"crossref","unstructured":"W. T. Abraham, P. B. Adamson, R. C. Bourge, M. F. Aaron, M. R. Costanzo, L. W. Stevenson, W. Strickland, S. Neelagaru, N. Raval, S. Krueger, S. Weiner, D. Shavelle, B. Jeffries, and J. S. Yadav, \u201cWireless Pulmonary Artery Haemodynamic Monitoring in Chronic Heart Failure: A Randomised Controlled Trial,\u201d The Lancet, Vol. 377, No. 9766, 2011, pp. 658\u2013666.","DOI":"10.1016\/S0140-6736(11)60101-3"},{"key":"22_CR41","doi-asserted-by":"crossref","unstructured":"M. R. Zile, T. D. Bennett, M. S. J. Sutton, Y. K. Cho, P. B. Adamson, M. F. Aaron, J. M. Aranda, W. T. Abraham, F. W. Smart, L. W. Stevenson, F. J. Kueffer, and R. C. Bourge, \u201cTransition from Chronic Compensated to Acute Decompensated Heart Failure - Pathophysiological Insights Obtained from Continuous Monitoring of Intracardiac Pressures,\u201d Circulation, Vol. 118, No. 14, Sep 2008, pp. 1433\u20131441.","DOI":"10.1161\/CIRCULATIONAHA.108.783910"},{"key":"22_CR42","unstructured":"CardioMEMS. (2007). Announces Fda Clearance of the $$\\text{ Endosure }{^TM}$$ Wireless Aaa Pressure Measurement System for Measuring Intrasac Pressure During Thoracic Aortic Aneurysm (Taa) Repair. Available: http:\/\/www.cardiomems.com\/content.asp?display=news&view=9."},{"key":"22_CR43","doi-asserted-by":"crossref","unstructured":"P. B. Adamson, W. T. Abraham, M. Aaron, J. M. Aranda Jr, R. C. Bourge, A. Smith, L. W. Stevenson, J. G. Bauman, and J. S. Yadav, \u201cChampion Trial Rationale and Design: The Long-Term Safety and Clinical Efficacy of a Wireless Pulmonary artery Pressure Monitoring System,\u201d Journal of Cardiac Failure, Vol. 17, No. 1, 2011, pp. 3\u201310.","DOI":"10.1016\/j.cardfail.2010.08.002"},{"key":"22_CR44","doi-asserted-by":"crossref","unstructured":"E. Y. Chow, A. L. Chlebowski, S. Chakraborty, W. J. Chappell, and P. P. Irazoqui, \u201cFully Wireless Implantable Cardiovascular Pressure Monitor Integrated with a Medical Stent,\u201d IEEE Transactions on Biomedical Engineering, Vol. 57, No. 6, Jun 2010, pp. 1487\u20131496.","DOI":"10.1109\/TBME.2010.2041058"},{"key":"22_CR45","doi-asserted-by":"crossref","unstructured":"P. Bingger, M. Zens, and P. Woias, \u201cHighly Flexible Capacitive Strain Gauge for Continuous Long-Term Blood Pressure Monitoring,\u201d Biomedical Microdevices, Vol. 14, 2012, pp. 573\u2013581.","DOI":"10.1007\/s10544-012-9636-9"},{"key":"22_CR46","doi-asserted-by":"crossref","unstructured":"Z. Yang, W. T. Liu, and E. Basham, \u201cInductor Modeling in Wireless Links for Implantable Electronics,\u201d IEEE Transactions on Magnetics, Vol. 43, No. 10, 2007, pp. 3851\u20133860.","DOI":"10.1109\/TMAG.2007.904189"},{"key":"22_CR47","doi-asserted-by":"crossref","unstructured":"A. K. RamRakhyani, S. Mirabbasi, and M. Chiao, \u201cDesign and Optimization of Resonance-Based Efficient Wireless Power Delivery Systems for Biomedical Implants,\u201d IEEE Transactions on Biomedical Circuits and Systems, Vol. 5, No. 1, Feb 2011, pp. 48\u201363.","DOI":"10.1109\/TBCAS.2010.2072782"},{"key":"22_CR48","doi-asserted-by":"crossref","unstructured":"A. Kurs, A. Karalis, R. Moffatt, J. D. Joannopoulos, P. Fisher, and M. Solja\u010di\u0107, \u201cWireless Power Transfer Via Strongly Coupled Magnetic Resonances,\u201d Science, Vol. 317, No. 5834, July 6, 2007 2007, pp. 83\u201386.","DOI":"10.1126\/science.1143254"},{"key":"22_CR49","doi-asserted-by":"crossref","unstructured":"J. Gemio, J. Parron, and J. Soler, \u201cHuman Body Effects on Implantable Antennas for Ism Bands Applications: Models Comparison and Propagation Losses Study,\u201d Progress in Electromagnetics Research, Vol. 110, 2010, pp. 437\u2013452.","DOI":"10.2528\/PIER10102604"},{"key":"22_CR50","doi-asserted-by":"crossref","unstructured":"E. Y. Chow, Y. Ouyang, B. Beier, W. J. Chappell, and P. P. Irazoqui, \u201cEvaluation of Cardiovascular Stents as Antennas for Implantable Wireless Applications,\u201d IEEE Transactions on Microwave Theory and Techniques, Vol. 57, No. 10, 2009, pp. 2523\u20132532.","DOI":"10.1109\/TMTT.2009.2029954"},{"key":"22_CR51","doi-asserted-by":"crossref","unstructured":"A. S. Y. Poon, S. O\u2019Driscoll, and T. H. Meng, \u201cOptimal Frequency for Wireless Power Transmission into Dispersive Tissue,\u201d IEEE Transactions on Antennas and Propagation, Vol. 58, No. 5, May 2010, pp. 1739\u20131750.","DOI":"10.1109\/TAP.2010.2044310"},{"key":"22_CR52","doi-asserted-by":"crossref","unstructured":"C. Y. Chen, Y. K. Lin, C. W. Hsu, C. Y. Wang, Y. L. Chueh, L. J. Chen, S. C. Lo, and L. J. Chou, \u201cCoaxial Metal-Silicide Ni2si\/C54-Tisi2 Nanowires,\u201d Nano Letters, Vol. 12, No. 5, May 2012, pp. 2254\u20132259.","DOI":"10.1021\/nl204459z"},{"key":"22_CR53","doi-asserted-by":"crossref","unstructured":"M. Ganzhorn, A. Vijayaraghavan, A. A. Green, S. Dehm, A. Voigt, M. Rapp, M. C. Hersam, and R. Krupke, \u201cA Scalable, Cmos-Compatible Assembly of Ambipolar Semiconducting Single-Walled Carbon Nanotube Devices,\u201d Advanced Materials, Vol. 23, No. 15, Apr 2011, pp. 1734\u20131738.","DOI":"10.1002\/adma.201004640"},{"key":"22_CR54","doi-asserted-by":"crossref","unstructured":"Z. L. Wang, \u201cTowards Self-Powered Nanosystems: From Nanogenerators to Nanopiezotronics,\u201d Advanced Functional Materials, Vol. 18, No. 22, Nov 2008, pp. 3553\u20133567.","DOI":"10.1002\/adfm.200800541"},{"key":"22_CR55","doi-asserted-by":"crossref","unstructured":"S. Vaddiraju, I. Tomazos, D. J. Burgess, F. C. Jain, and F. Papadimitrakopoulos, \u201cEmerging Synergy between Nanotechnology and Implantable Biosensors: A Review,\u201d Biosensors and Bioelectronics, Vol. 25, No. 7, 2010, pp. 1553\u20131565.","DOI":"10.1016\/j.bios.2009.12.001"},{"key":"22_CR56","doi-asserted-by":"crossref","unstructured":"D. M. Whelan, W. J. van der Giessen, S. C. Krabbendam, E. A. van Vliet, P. D. Verdouw, P. W. Serruys, and H. M. M. van Beusekom, \u201cBiocompatibility of Phosphorylcholine Coated Stents in Normal Porcine Coronary Arteries,\u201d Heart, Vol. 83, No. 3, Mar 2000, pp. 338\u2013345.","DOI":"10.1136\/heart.83.3.338"},{"key":"22_CR57","doi-asserted-by":"crossref","unstructured":"K. Nakano, K. Egashira, S. Masuda, K. Funakoshi, G. Zhao, S. Kimura, T. Matoba, K. Sueishi, Y. Endo, Y. Kawashima, K. Hara, H. Tsujimoto, R. Tominaga, and K. Sunagawa, \u201cFormulation of Nanoparticle-Eluting Stents by a Cationic Electrodeposition Coating Technology: Efficient Nano-Drug Delivery Via Bioabsorbable Polymeric Nanoparticle-Eluting Stents in Porcine Coronary Arteries,\u201d JACC: Cardiovascular Interventions, Vol. 2, No. 4, 2009, pp. 277\u2013283.","DOI":"10.1016\/j.jcin.2008.08.023"},{"key":"22_CR58","doi-asserted-by":"crossref","unstructured":"M. C. Loya, K. S. Brammer, C. Choi, L. H. Chen, and S. Jin, \u201cPlasma-Induced Nanopillars on Bare Metal Coronary Stent Surface for Enhanced Endothelialization,\u201d Acta Biomaterialia, Vol. 6, No. 12, 2010, pp. 4589\u20134595.","DOI":"10.1016\/j.actbio.2010.07.007"},{"key":"22_CR59","doi-asserted-by":"crossref","unstructured":"A. W. Martinez and E. L. Chaikof, \u201cMicrofabrication and Nanotechnology in Stent Design,\u201d Wiley Interdisciplinary Reviews-Nanomedicine and, Nanobiotechnology, 3(3), May-Jun 2011, pp. 256\u2013268.","DOI":"10.1002\/wnan.123"}],"container-title":["Handbook of Medical and Healthcare Technologies"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-1-4614-8495-0_22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T05:25:56Z","timestamp":1675229156000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-1-4614-8495-0_22"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013]]},"ISBN":["9781461484943","9781461484950"],"references-count":59,"URL":"https:\/\/doi.org\/10.1007\/978-1-4614-8495-0_22","relation":{},"subject":[],"published":{"date-parts":[[2013]]},"assertion":[{"value":"21 November 2013","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}}]}}