{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T00:33:24Z","timestamp":1781656404343,"version":"3.54.5"},"publisher-location":"Cham","reference-count":14,"publisher":"Springer International Publishing","isbn-type":[{"value":"9783030009274","type":"print"},{"value":"9783030009281","type":"electronic"}],"license":[{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018]]},"DOI":"10.1007\/978-3-030-00928-1_4","type":"book-chapter","created":{"date-parts":[[2018,9,13]],"date-time":"2018-09-13T03:00:42Z","timestamp":1536807642000},"page":"30-38","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["DeepASL: Kinetic Model Incorporated Loss for Denoising Arterial Spin Labeled MRI via Deep Residual Learning"],"prefix":"10.1007","author":[{"given":"Cagdas","family":"Ulas","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giles","family":"Tetteh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephan","family":"Kaczmarz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christine","family":"Preibisch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bjoern H.","family":"Menze","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,9,26]]},"reference":[{"key":"4_CR1","unstructured":"Abadi, M., et al.: TensorFlow: large-scale machine learning on heterogeneous systems (2015). https:\/\/www.tensorflow.org\/, software available from tensorflow.org"},{"issue":"1","key":"4_CR2","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1002\/mrm.25197","volume":"73","author":"DC Alsop","year":"2015","unstructured":"Alsop, D.C.: Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: a consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia. MRM 73(1), 102\u2013116 (2015)","journal-title":"MRM"},{"issue":"3","key":"4_CR3","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1007\/s10334-010-0209-8","volume":"23","author":"A Bibic","year":"2010","unstructured":"Bibic, A., et al.: Denoising of arterial spin labeling data: wavelet-domain filtering compared with gaussian smoothing. MAGMA 23(3), 125\u2013137 (2010)","journal-title":"MAGMA"},{"issue":"3","key":"4_CR4","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1002\/mrm.1910400308","volume":"40","author":"RB Buxton","year":"1998","unstructured":"Buxton, R.B., et al.: A general kinetic model for quantitative perfusion imaging with arterial spin labeling. MRM 40(3), 383\u2013396 (1998)","journal-title":"MRM"},{"key":"4_CR5","doi-asserted-by":"crossref","unstructured":"Fang, R., et al.: A spatio-temporal low-rank total variation approach for denoising arterial spin labeling MRI data. In: IEEE ISBI, pp. 498\u2013502, April 2015","DOI":"10.1109\/ISBI.2015.7163920"},{"key":"4_CR6","doi-asserted-by":"crossref","unstructured":"He, K., et al.: Delving deep into rectifiers: surpassing human-level performance on imagenet classification. In: IEEE ICCV, pp. 1026\u20131034, December 2015","DOI":"10.1109\/ICCV.2015.123"},{"key":"4_CR7","doi-asserted-by":"crossref","unstructured":"He, K., et al.: Deep residual learning for image recognition. In: IEEE CVPR, pp. 770\u2013778, June 2016","DOI":"10.1109\/CVPR.2016.90"},{"key":"4_CR8","doi-asserted-by":"crossref","unstructured":"Kiku, D., et al.: Residual interpolation for color image demosaicking. In: IEEE ICIP, pp. 2304\u20132308, September 2013","DOI":"10.1109\/ICIP.2013.6738475"},{"issue":"2","key":"4_CR9","doi-asserted-by":"publisher","first-page":"658","DOI":"10.1148\/radiol.2017171154","volume":"287","author":"KH Kim","year":"2018","unstructured":"Kim, K.H., et al.: Improving arterial spin labeling by using deep learning. Radiology 287(2), 658\u2013666 (2018)","journal-title":"Radiology"},{"issue":"9","key":"4_CR10","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1089\/brain.2014.0290","volume":"5","author":"X Liang","year":"2015","unstructured":"Liang, X.: Voxel-wise functional connectomics using arterial spin labeling functional magnetic resonance imaging: the role of denoising. Brain Connect. 5(9), 543\u201353 (2015)","journal-title":"Brain Connect."},{"key":"4_CR11","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1007\/978-3-319-66185-8_22","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2017","author":"D Owen","year":"2017","unstructured":"Owen, D., et al.: Anatomy-driven modelling of spatial correlation for regularisation of arterial spin labelling images. In: Descoteaux, M., et al. (eds.) MICCAI 2017. LNCS, vol. 10434, pp. 190\u2013197. Springer, Cham (2017). https:\/\/doi.org\/10.1007\/978-3-319-66185-8_22"},{"key":"4_CR12","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.neuroimage.2017.05.054","volume":"157","author":"SM Spann","year":"2017","unstructured":"Spann, S.M., et al.: Spatio-temporal TGV denoising for ASL perfusion imaging. Neuroimage 157, 81\u201396 (2017)","journal-title":"Neuroimage"},{"issue":"3","key":"4_CR13","doi-asserted-by":"publisher","first-page":"715","DOI":"10.1002\/mrm.22319","volume":"64","author":"JA Wells","year":"2010","unstructured":"Wells, J.A., et al.: Reduction of errors in ASL cerebral perfusion and arterial transit time maps using image de-noising. MRM 64(3), 715\u2013724 (2010)","journal-title":"MRM"},{"issue":"7","key":"4_CR14","doi-asserted-by":"publisher","first-page":"3142","DOI":"10.1109\/TIP.2017.2662206","volume":"26","author":"K Zhang","year":"2017","unstructured":"Zhang, K.: Beyond a gaussian denoiser: residual learning of deep CNN for image denoising. IEEE Trans. Image Process. 26(7), 3142\u20133155 (2017)","journal-title":"IEEE Trans. Image Process."}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer Assisted Intervention \u2013 MICCAI 2018"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-00928-1_4","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,13]],"date-time":"2023-09-13T00:03:19Z","timestamp":1694563399000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-030-00928-1_4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018]]},"ISBN":["9783030009274","9783030009281"],"references-count":14,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-00928-1_4","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"value":"0302-9743","type":"print"},{"value":"1611-3349","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018]]},"assertion":[{"value":"26 September 2018","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"MICCAI","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Medical Image Computing and Computer-Assisted Intervention","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Granada","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Spain","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2018","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"16 September 2018","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"20 September 2018","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"miccai2018","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}]}}