{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T14:25:41Z","timestamp":1762007141545,"version":"build-2065373602"},"publisher-location":"Cham","reference-count":12,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783030009304"},{"type":"electronic","value":"9783030009311"}],"license":[{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018]]},"DOI":"10.1007\/978-3-030-00931-1_12","type":"book-chapter","created":{"date-parts":[[2018,9,12]],"date-time":"2018-09-12T23:26:09Z","timestamp":1536794769000},"page":"98-106","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Deep Learning with Synthetic Diffusion MRI Data for Free-Water Elimination in Glioblastoma Cases"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8054-0426","authenticated-orcid":false,"given":"Miguel","family":"Molina-Romero","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2963-7772","authenticated-orcid":false,"given":"Benedikt","family":"Wiestler","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3709-3557","authenticated-orcid":false,"given":"Pedro A.","family":"G\u00f3mez","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0087-9134","authenticated-orcid":false,"given":"Marion I.","family":"Menzel","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4136-5690","authenticated-orcid":false,"given":"Bjoern H.","family":"Menze","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2018,9,13]]},"reference":[{"key":"12_CR1","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1093\/med\/9780195369779.003.0033","volume-title":"Diffusion MRI, Chap. 33","author":"AS Field","year":"2010","unstructured":"Field, A.S.: Diffusion imaging in brain tumors. In: Jones, D.K. (ed.) Diffusion MRI, Chap. 33, pp. 547\u2013563. Oxford University Press, Oxford (2010)"},{"issue":"2","key":"12_CR2","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1148\/radiol.2016152832","volume":"283","author":"S Bette","year":"2017","unstructured":"Bette, S., et al.: Local fractional anisotropy is reduced in areas with tumor recurrence in glioblastoma. Radiology 283(2), 499\u2013507 (2017)","journal-title":"Radiology"},{"key":"12_CR3","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"605","DOI":"10.1007\/978-3-319-46726-9_70","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2016","author":"Z Eaton-Rosen","year":"2016","unstructured":"Eaton-Rosen, Z., et al.: Beyond the resolution limit: diffusion parameter estimation in partial volume. In: Ourselin, S., Joskowicz, L., Sabuncu, M.R., Unal, G., Wells, W. (eds.) MICCAI 2016. LNCS, vol. 9902, pp. 605\u2013612. Springer, Cham (2016). https:\/\/doi.org\/10.1007\/978-3-319-46726-9_70"},{"issue":"2","key":"12_CR4","doi-asserted-by":"publisher","first-page":"1394","DOI":"10.1016\/j.neuroimage.2011.08.043","volume":"59","author":"C Metzler-Baddeley","year":"2012","unstructured":"Metzler-Baddeley, C., et al.: How and how not to correct for CSF-contamination in diffusion MRI. Neuroimage 59(2), 1394\u20131403 (2012)","journal-title":"Neuroimage"},{"key":"12_CR5","unstructured":"Pierpaoli, C., Jones, D.K.: Removing CSF contamination in brain DT-MRIs by using a two-compartment tensor model. In: ISMRM, Kyoto, p. 1215 (2004)"},{"key":"12_CR6","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1002\/mrm.22055","volume":"730","author":"O Pasternak","year":"2009","unstructured":"Pasternak, O., et al.: Free water elimination and mapping from diffusion MRI. Magn. Reson. Med. 730, 717\u2013730 (2009)","journal-title":"Magn. Reson. Med."},{"key":"12_CR7","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1016\/j.neuroimage.2014.09.053","volume":"103","author":"AR Hoy","year":"2014","unstructured":"Hoy, A.R., et al.: Optimization of a free water elimination two-compartment model for diffusion tensor imaging. Neuroimage 103, 323\u2013333 (2014)","journal-title":"Neuroimage"},{"key":"12_CR8","series-title":"Lecture Notes in Computer Science","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1007\/978-3-319-66182-7_70","volume-title":"Medical Image Computing and Computer Assisted Intervention - MICCAI 2017","author":"R Tanno","year":"2017","unstructured":"Tanno, R., et al.: Bayesian image quality transfer with CNNs: exploring uncertainty in dMRI super-resolution. In: Descoteaux, M., Maier-Hein, L., Franz, A., Jannin, P., Collins, D.L., Duchesne, S. (eds.) MICCAI 2017. LNCS, vol. 10433, pp. 611\u2013619. Springer, Cham (2017). https:\/\/doi.org\/10.1007\/978-3-319-66182-7_70"},{"issue":"March","key":"12_CR9","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1016\/j.neuroimage.2017.02.089","volume":"152","author":"DC Alexander","year":"2017","unstructured":"Alexander, D.C., et al.: Image quality transfer and applications in diffusion MRI. Neuroimage 152(March), 283\u2013298 (2017)","journal-title":"Neuroimage"},{"key":"12_CR10","doi-asserted-by":"publisher","first-page":"2155","DOI":"10.1002\/mrm.27181","volume":"80","author":"M Molina-Romero","year":"2018","unstructured":"Molina-Romero, M., et al.: A diffusion model-free framework with echo time dependence for free-water elimination and brain tissue microstructure characterization. Magn. Reson. Med. 80, 2155\u20132172 (2018)","journal-title":"Magn. Reson. Med."},{"key":"12_CR11","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1016\/j.neuroimage.2016.08.016","volume":"142","author":"J Veraart","year":"2016","unstructured":"Veraart, J., et al.: Denoising of diffusion MRI using random matrix theory. Neuroimage 142, 394\u2013406 (2016)","journal-title":"Neuroimage"},{"issue":"5","key":"12_CR12","doi-asserted-by":"publisher","first-page":"1088","DOI":"10.1002\/mrm.20426","volume":"53","author":"L Chang","year":"2005","unstructured":"Chang, L., et al.: Restore: robust estimation of tensors by outlier rejection. Magn. Reson. Med. 53(5), 1088\u20131095 (2005)","journal-title":"Magn. Reson. Med."}],"container-title":["Lecture Notes in Computer Science","Medical Image Computing and Computer Assisted Intervention \u2013 MICCAI 2018"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-00931-1_12","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,13]],"date-time":"2024-03-13T20:04:04Z","timestamp":1710360244000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/978-3-030-00931-1_12"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018]]},"ISBN":["9783030009304","9783030009311"],"references-count":12,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-00931-1_12","relation":{},"ISSN":["0302-9743","1611-3349"],"issn-type":[{"type":"print","value":"0302-9743"},{"type":"electronic","value":"1611-3349"}],"subject":[],"published":{"date-parts":[[2018]]},"assertion":[{"value":"13 September 2018","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"MICCAI","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"International Conference on Medical Image Computing and Computer-Assisted Intervention","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Granada","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Spain","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2018","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"16 September 2018","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"20 September 2018","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"11","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"miccai2018","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"https:\/\/www.miccai2018.org\/en\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}]}}