{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,9,10]],"date-time":"2024-09-10T20:12:04Z","timestamp":1725999124455},"publisher-location":"Cham","reference-count":11,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783030010539"},{"type":"electronic","value":"9783030010546"}],"license":[{"start":{"date-parts":[[2018,11,9]],"date-time":"2018-11-09T00:00:00Z","timestamp":1541721600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-030-01054-6_55","type":"book-chapter","created":{"date-parts":[[2018,11,8]],"date-time":"2018-11-08T14:47:05Z","timestamp":1541688425000},"page":"791-803","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Selective Stiffening Mechanism for Surgical-Assist Soft Robotic Applications"],"prefix":"10.1007","author":[{"given":"Sunita","family":"Chauhan","sequence":"first","affiliation":[]},{"given":"Mathew","family":"Guerra","sequence":"additional","affiliation":[]},{"given":"Ranjaka","family":"De Mel","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2018,11,9]]},"reference":[{"key":"55_CR1","doi-asserted-by":"crossref","unstructured":"IEEE: Soft Robotics\u2014The Next Industrial Revolution? IEEE Robot. Autom. Mag. 23(3), 17\u201320 (2016)","DOI":"10.1109\/MRA.2016.2588018"},{"key":"55_CR2","volume-title":"Statics and Mechanics of Materials","author":"RC Hibbeler","year":"2011","unstructured":"Hibbeler, R.C.: Statics and Mechanics of Materials. Prentice Hall, Jurong (2011)"},{"issue":"3","key":"55_CR3","doi-asserted-by":"publisher","first-page":"2","DOI":"10.3390\/act6030023","volume":"6","author":"L Blanc","year":"2017","unstructured":"Blanc, L., Delchambre, A., Lambert, P.: Flexible medical devices: review of controllable stiffness solutions. Actuators 6(3), 2 (2017)","journal-title":"Actuators"},{"key":"55_CR4","unstructured":"Steltz, E., Mozeika, A., Rembisz, J., Corson, N., Jaeger, H.: Jamming as an enabling technology for soft robotics. In: SPIE 7642, Electroactive Polymer Actuators and Devices (EAPAD) 2010, 764225, San Diego, California, United States (2010)"},{"issue":"44","key":"55_CR5","doi-asserted-by":"publisher","first-page":"18809","DOI":"10.1073\/pnas.1003250107","volume":"107","author":"E Brown","year":"2010","unstructured":"Brown, E., Rodenberg, N., Amend, J., Mozeika, A., Steltz, E., Zakin, M.R., Lipson, H., Jaeger, H.M.: Universal robotic gripper based on the jamming of granular material. Proc. Natl. Acad. Sci. U.S.A. 107(44), 18809\u201318814 (2010)","journal-title":"Proc. Natl. Acad. Sci. U.S.A."},{"issue":"4","key":"55_CR6","doi-asserted-by":"publisher","first-page":"1031","DOI":"10.1109\/TRO.2013.2256313","volume":"29","author":"Y-J Kim","year":"2013","unstructured":"Kim, Y.-J., Cheng, S., Kim, S., Iagnemma, K.: A novel layer jamming mechanism with tunable stiffness capability for minimally invasive surgery. IEEE Trans. Rob. 29(4), 1031\u20131042 (2013)","journal-title":"IEEE Trans. Rob."},{"issue":"5","key":"55_CR7","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1007\/s11548-014-0981-4","volume":"9","author":"S Zuo","year":"2014","unstructured":"Zuo, S., Iijima, K., Tokumiya, T., Masamune, K.: Variable stiffness outer sheath with \u201cDragon skin\u201d structure and negative pneumatic shape-locking mechanism. Int. J. Comput. Assist. Radiol. Surg. 9(5), 857\u2013865 (2014)","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"55_CR8","doi-asserted-by":"crossref","unstructured":"Moses, M.S., Kutzer, M.D., Ma, H., Armand, M.: A continuum manipulator made of interlocking fibers. In: 2013 IEEE International Conference on Robotics and Automation (ICRA), Karlsruhe, Germany (2013)","DOI":"10.1109\/ICRA.2013.6631142"},{"issue":"2","key":"55_CR9","first-page":"524","volume":"59","author":"J Loeve","year":"2011","unstructured":"Loeve, J., Plettenburg, D.H., Breedveld, P., Dankelman, J.: Endoscope shaft-rigidity control mechanism: \u201cFORGUIDE\u201d. IEEE Trans. Biomed. Eng. 59(2), 524\u2013551 (2011)","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"55_CR10","unstructured":"Robertsons, \u201cSection\u00a08 - Wire Rope,\u201d in Robertsons Product Catalogue 2014 edition, Queensland, Robertsons (2014)"},{"issue":"1","key":"55_CR11","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1007\/s00464-010-1155-2","volume":"25","author":"L Trejos","year":"2011","unstructured":"Trejos, L., Jayaraman, S., Patel, R.V., Naish, M.D., Schlachta, C.M.: Force sensing in natural orifice transluminal endoscopic surgery. Surg. Endosc. 25(1), 186\u2013192 (2011)","journal-title":"Surg. Endosc."}],"container-title":["Advances in Intelligent Systems and Computing","Intelligent Systems and Applications"],"original-title":[],"link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-01054-6_55","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,11,8]],"date-time":"2018-11-08T15:17:16Z","timestamp":1541690236000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-030-01054-6_55"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11,9]]},"ISBN":["9783030010539","9783030010546"],"references-count":11,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-01054-6_55","relation":{},"ISSN":["2194-5357","2194-5365"],"issn-type":[{"type":"print","value":"2194-5357"},{"type":"electronic","value":"2194-5365"}],"subject":[],"published":{"date-parts":[[2018,11,9]]},"assertion":[{"value":"IntelliSys","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Proceedings of SAI Intelligent Systems Conference","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"London","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"United Kingdom","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2018","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"6 September 2018","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"7 September 2018","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"intellisys2018","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"http:\/\/saiconference.com\/IntelliSys2018\/CallforPapers","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}