{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,28]],"date-time":"2025-03-28T07:20:37Z","timestamp":1743146437626,"version":"3.40.3"},"publisher-location":"Cham","reference-count":15,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783030043230"},{"type":"electronic","value":"9783030043247"}],"license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-030-04324-7_49","type":"book-chapter","created":{"date-parts":[[2019,1,17]],"date-time":"2019-01-17T11:37:14Z","timestamp":1547725034000},"page":"399-404","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Estimating the Outdoor PM10 Concentration Through Wireless Sensor Network for Smart Metering"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8449-1406","authenticated-orcid":false,"given":"D.","family":"Capriglione","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8146-6088","authenticated-orcid":false,"given":"M.","family":"Carrat\u00f9","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6220-4100","authenticated-orcid":false,"given":"M.","family":"Ferro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5593-7325","authenticated-orcid":false,"given":"A.","family":"Pietrosanto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9607-866X","authenticated-orcid":false,"given":"P.","family":"Sommella","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,1,18]]},"reference":[{"key":"49_CR1","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1016\/j.envint.2015.08.006","volume":"85","author":"Malek Bentayeb","year":"2015","unstructured":"Bentayeb, M., Wagner, V., Stempfelet, M., Zins, M., et al.: Association between longterm exposure to air pollution and mortality in France: a 25-year follow-up study. Environ. Int. 85, 5\u201314 (2015)","journal-title":"Environment International"},{"key":"49_CR2","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/j.envint.2016.12.007","volume":"99","author":"Nuria Castell","year":"2017","unstructured":"Castell, N., Dauge, F.R., Schneider, P., Vogt, M., et al.: Can commercial low-cost sensor platforms contribute to air quality monitoring and exposure estimates. Environ. Int. 99, 293\u2013302 (2017)","journal-title":"Environment International"},{"doi-asserted-by":"publisher","unstructured":"Cerro, G., Ferdinandi, M., Ferrigno, L., Molinara, M.: Preliminary realization of a monitoring system of activated carbon filter RLI based on the SENSIPLUS\u00ae microsensor platform. In: 2017 IEEE International Workshop on Measurement and Networking (M&N), Naples, pp. 1\u20135 (2017). \n                    https:\/\/doi.org\/10.1109\/iwmn.2017.8078361","key":"49_CR3","DOI":"10.1109\/iwmn.2017.8078361"},{"unstructured":"CitiSense Homepage. \n                    http:\/\/www.citi-sense.eu\n                    \n                  . Accessed 03 Mar 2018","key":"49_CR4"},{"unstructured":"Everyaware Homepage. \n                    http:\/\/www.everyaware.eu\n                    \n                  . Accessed 03 Mar 2018","key":"49_CR5"},{"issue":"10","key":"49_CR6","doi-asserted-by":"publisher","first-page":"105101","DOI":"10.1088\/0957-0233\/20\/10\/105101","volume":"20","author":"G Betta","year":"2009","unstructured":"Betta, G., Capriglione, D., Ferrigno, L., Laracca, M.A.: Measurement-driven approach to assess power line telecommunication (PLT) network quality of service (QoS) performance parameters. Meas. Sci. Technol. 20(10), art. no. 105101 (2009)","journal-title":"Measurement Science and Technology"},{"issue":"11","key":"49_CR7","doi-asserted-by":"publisher","first-page":"4513","DOI":"10.1109\/JSEN.2013.2271275","volume":"13","author":"Andrea Bernieri","year":"2013","unstructured":"Bernieri, A., Betta, G., Ferrigno, L., Laracca, M.: Improving performance of GMR sensors. IEEE Sens. J. 13(11), art. no. 6547705, 4513\u20134521 (2013)","journal-title":"IEEE Sensors Journal"},{"issue":"23","key":"49_CR8","doi-asserted-by":"publisher","first-page":"7849","DOI":"10.1109\/JSEN.2017.2738102","volume":"17","author":"M Carrat\u00f9","year":"2017","unstructured":"Carrat\u00f9, M., Ferro, M., Paciello, V., Pietrosanto, A., Sommella, P.: Performance analysis of wM-Bus networks for smart metering. IEEE Sens. J. 17(23), 7849\u20137856 (2017)","journal-title":"IEEE Sens. J."},{"unstructured":"Communication systems for meters and remote reading of meters Part 4: Wireless meter readout (Radio meter reading for operation in SRD band). EN 13757-4:2013 (2013)","key":"49_CR9"},{"unstructured":"IEC Electricity metering\u2014Data exchange for meter reading, tariff and load control\u2014Part 53: COSEM application layer. IEC 62056-53 (2006)","key":"49_CR10"},{"doi-asserted-by":"crossref","unstructured":"Carrat\u00f9, M., Ferro, M., Pietrosanto, A., Sommella, P.: Adopting smart metering RF networks for particulate matter distributed measurements. In: IMEKO TC19 Symposium: Metrology on Environmental Instrumentation and Measurements (EnvIMEKO 17), pp. 50\u201355, Aguascalientes, Mexico (2017)","key":"49_CR11","DOI":"10.1109\/JSEN.2017.2738102"},{"doi-asserted-by":"crossref","unstructured":"Di Leo, G., Liguori, C., Paciello, V., Pietrosanto, A., Sommella, P.: Towards visual smart metering exploiting wM-Bus and DLMS\/COSEM. In: IEEE International Conference on Computational Intelligence and Virtual Environments for Measurement Systems and Applications (CIVEMSA), pp. 1\u20136, Shenzhen, China (2015)","key":"49_CR12","DOI":"10.1109\/CIVEMSA.2015.7158602"},{"doi-asserted-by":"crossref","unstructured":"Rajasegarar, S., Zhang, P., Zhou, Y., et al.: High resolution spatio-temporal monitoring of air pollutants using wireless sensor networks. In: IEEE 9th International Conference on Intelligent Sensors Networks and Information Processing Symposium on Intelligent Sensors, pp. 1\u20136, Singapore (2014)","key":"49_CR13","DOI":"10.1109\/ISSNIP.2014.6827607"},{"unstructured":"Directive 2008\/50\/EC of the European Parliament and of the Council of 21 May 2008 on ambient air quality and cleaner air for Europe (2008)","key":"49_CR14"},{"unstructured":"UNI\/TS 11291-1:2013: UNI, Italian Committee for Standardization, pp. 1\u201328 (2013)","key":"49_CR15"}],"container-title":["Lecture Notes in Electrical Engineering","Sensors"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-04324-7_49","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,17]],"date-time":"2019-05-17T23:04:22Z","timestamp":1558134262000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-030-04324-7_49"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019]]},"ISBN":["9783030043230","9783030043247"],"references-count":15,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-04324-7_49","relation":{},"ISSN":["1876-1100","1876-1119"],"issn-type":[{"type":"print","value":"1876-1100"},{"type":"electronic","value":"1876-1119"}],"subject":[],"published":{"date-parts":[[2019]]},"assertion":[{"value":"18 January 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"CNS","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Convegno Nazionale Sensori","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Catania","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Italy","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2018","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"21 February 2018","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"23 February 2018","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"4","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"cns2018","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"http:\/\/www.cns2018.it\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}