{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,27]],"date-time":"2025-03-27T06:43:51Z","timestamp":1743057831381,"version":"3.40.3"},"publisher-location":"Cham","reference-count":11,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783030043230"},{"type":"electronic","value":"9783030043247"}],"license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-030-04324-7_8","type":"book-chapter","created":{"date-parts":[[2019,1,17]],"date-time":"2019-01-17T11:37:14Z","timestamp":1547725034000},"page":"53-59","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Yeast-DMFC Device Using Glucose as Fuel: Analytical and Energetic Applications. Preliminary Results"],"prefix":"10.1007","author":[{"given":"Mauro","family":"Tomassetti","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emanuele","family":"Dell\u2019Aglio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Riccardo","family":"Angeloni","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mauro","family":"Castrucci","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria Pia","family":"Sammartino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luigi","family":"Campanella","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,1,18]]},"reference":[{"key":"8_CR1","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.cej.2016.06.020","volume":"304","author":"M Zeppilli","year":"2016","unstructured":"Zeppilli, M., Lai, A., Villano, M., Majone, M.: Anion vs cation exchange membrane strongly affect mechanisms and yield of CO2 fixation in a microbial electrolysis cell. Chem. Eng. J. 304, 10\u201319 (2016). \n                    https:\/\/doi.org\/10.1016\/j.cej.2016.06.020","journal-title":"Chem. Eng. J."},{"key":"8_CR2","doi-asserted-by":"publisher","first-page":"445","DOI":"10.3303\/CET1649075","volume":"49","author":"M Zeppilli","year":"2016","unstructured":"Zeppilli, M., Ceccarelli, I., Villano, M., Majone, M.: Reduction of carbon dioxide into acetate in a fully biological microbial electrolysis cell. Chem. Eng. Trans. 49, 445\u2013450 (2016). \n                    https:\/\/doi.org\/10.3303\/CET1649075","journal-title":"Chem. Eng. Trans."},{"key":"8_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.bioelechem.2015.07.008","volume":"107","author":"M Villano","year":"2016","unstructured":"Villano, M., Ralo, C., Zeppilli, M., Aulenta, F., Majone, M.: Influence of the set anode potential on the performance and internal energy losses of a methane-producing microbial electrolysis cell. Bioelectrochemistry 107, 1\u20138 (2016). \n                    https:\/\/doi.org\/10.1016\/j.bioelechem.2015.07.008","journal-title":"Bioelectrochemistry"},{"key":"8_CR4","doi-asserted-by":"publisher","first-page":"882","DOI":"10.13140\/2.1.1079.3601","volume":"11","author":"S Brutti","year":"2014","unstructured":"Brutti, S., Scipioni, R., Navarra, M.A., Panero, S., Allodi, V., Giarola, M., Mariotto, G.: SnO2-Nafion\u00ae nanocomposite polymer electrolytes for fuel cell applications. Int. J. Nanotechnol. 11, 882\u2013896 (2014). \n                    https:\/\/doi.org\/10.13140\/2.1.1079.3601","journal-title":"Int. J. Nanotechnol."},{"key":"8_CR5","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1002\/fuce.200800066","volume":"3","author":"MA Navarra","year":"2009","unstructured":"Navarra, M.A., Abbati, C., Croce, F., Scrosati, B.: Temperature-dependent performances of a fuel cell using a superacid zirconiadoped nafion polymer electrolyte. Fuel Cells 3, 222\u2013225 (2009). \n                    https:\/\/doi.org\/10.1002\/fuce.200800066","journal-title":"Fuel Cells"},{"key":"8_CR6","doi-asserted-by":"publisher","first-page":"921","DOI":"10.1016\/j.snb.2017.10.025","volume":"256","author":"P Bollella","year":"2018","unstructured":"Bollella, P., Fusco, G., Stevar, D., Gorton, L., Ludwig, R., Ma, S., Boer, H., Koivula, A., Tortolini, C., Favero, G., Antiochia, R., Mazzei, F.: A glucose\/oxygen enzymatic fuel cell based on gold nanoparticles modified graphene screen-printed electrode. Proof-of-concept in human saliva. Sens. Actuators B Chem. 256, 921\u2013930 (2018). \n                    https:\/\/doi.org\/10.1016\/j.snb.2017.10.025","journal-title":"Sens. Actuators B Chem."},{"key":"8_CR7","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1002\/elan.201400409","volume":"27","author":"M Carbone","year":"2015","unstructured":"Carbone, M., Gorton, L., Antiochia, R.: An overview of the latest graphene-based sensors for glucose detection: the effects of graphene defects. Electroanalysis 27, 16\u201331 (2015). \n                    https:\/\/doi.org\/10.1002\/elan.201400409","journal-title":"Electroanalysis"},{"key":"8_CR8","doi-asserted-by":"publisher","first-page":"1001","DOI":"10.1016\/j.electacta.2015.12.171","volume":"191","author":"M Tomassetti","year":"2016","unstructured":"Tomassetti, M., Angeloni, R., Merola, G., Castrucci, M., Campanella, L.: Catalytic fuel cell used as an analytical tool for methanol and ethanol determination. Application to ethanol determination in alcoholic beverages. Electrochim. Acta 191, 1001\u20131009 (2016). \n                    https:\/\/doi.org\/10.1016\/j.electacta.2015.12.171","journal-title":"Electrochim. Acta"},{"issue":"2","key":"8_CR9","doi-asserted-by":"publisher","first-page":"91","DOI":"10.21014\/acta_imeko.v7i2.444","volume":"7","author":"Mauro Tomassetti","year":"2018","unstructured":"Tomassetti, M., Angeloni, R., Castrucci, M., Martini, E., Campanella, L.: Ethanol content determination in hard liquor drinks, beers, and wines, using a catalytic fuel cell. Comparison with other two conventional enzymatic biosensors: correlation and statisitcal data. Acta Imeko. 7(2), 91\u201395 (2018). ISSN: 2221-870X (in press)","journal-title":"ACTA IMEKO"},{"key":"8_CR10","doi-asserted-by":"publisher","first-page":"7311","DOI":"10.1007\/s00216-016-9795-2","volume":"408","author":"M Tomassetti","year":"2016","unstructured":"Tomassetti, M., Merola, G., Angeloni, R., Marchiandi, S., Campanella, L.: Further development on DMFC device used for analytical purpose: real applications in the pharmaceutical field and possible in biological fluids. Anal. Bioanal. Chem. 408, 7311\u20137319 (2016). \n                    https:\/\/doi.org\/10.1007\/s00216-016-9795-2","journal-title":"Anal. Bioanal. Chem."},{"key":"8_CR11","unstructured":"https:\/\/en.wikipedia.org\/wiki\/Ethanol_fermentation"}],"container-title":["Lecture Notes in Electrical Engineering","Sensors"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-04324-7_8","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,17]],"date-time":"2019-05-17T23:01:46Z","timestamp":1558134106000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-030-04324-7_8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019]]},"ISBN":["9783030043230","9783030043247"],"references-count":11,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-04324-7_8","relation":{},"ISSN":["1876-1100","1876-1119"],"issn-type":[{"type":"print","value":"1876-1100"},{"type":"electronic","value":"1876-1119"}],"subject":[],"published":{"date-parts":[[2019]]},"assertion":[{"value":"18 January 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"CNS","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Convegno Nazionale Sensori","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Catania","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Italy","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2018","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"21 February 2018","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"23 February 2018","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"4","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"cns2018","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"http:\/\/www.cns2018.it\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}