{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,27]],"date-time":"2025-03-27T11:37:50Z","timestamp":1743075470721,"version":"3.40.3"},"publisher-location":"Cham","reference-count":7,"publisher":"Springer International Publishing","isbn-type":[{"type":"print","value":"9783030043230"},{"type":"electronic","value":"9783030043247"}],"license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019]]},"DOI":"10.1007\/978-3-030-04324-7_9","type":"book-chapter","created":{"date-parts":[[2019,1,17]],"date-time":"2019-01-17T11:37:14Z","timestamp":1547725034000},"page":"61-68","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["YCoO3 Resistive Gas Sensors for the Detection of NO2 in \u2018Resistance Controlled Mode\u2019"],"prefix":"10.1007","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0168-9404","authenticated-orcid":false,"given":"Tommaso","family":"Addabbo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0916-1516","authenticated-orcid":false,"given":"Ada","family":"Fort","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2410-1581","authenticated-orcid":false,"given":"Marco","family":"Mugnaini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2509-6566","authenticated-orcid":false,"given":"Valerio","family":"Vignoli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,1,18]]},"reference":[{"key":"9_CR1","doi-asserted-by":"publisher","unstructured":"Addabbo, T., Fort, A., Mugniani, M., Parri, L., Vignoli, V.: An unconventional type of measurement with chemoresistive gas sensors exploiting a versatile measurement system. In: 2017 New Generation of Circuit and Systems (NGCAS), pp. 113\u2013116. IEEE Press (2017). \n                    https:\/\/doi.org\/10.1109\/ngcas.2017.34","DOI":"10.1109\/ngcas.2017.34"},{"key":"9_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.snb.2016.01.081","volume":"229","author":"M Dominguez-Pumar","year":"2016","unstructured":"Dominguez-Pumar, M., Kowalski, L., Calavia, R., Llobet, E.: Smart control of chemical gas sensors for the reduction of their time response. Sens. Actuators B Chem. 229, 1\u20136 (2016). \n                    https:\/\/doi.org\/10.1016\/j.snb.2016.01.081","journal-title":"Sens. Actuators B Chem."},{"key":"9_CR3","doi-asserted-by":"publisher","first-page":"1137","DOI":"10.1016\/j.snb.2015.07.079","volume":"221","author":"T Addabbo","year":"2015","unstructured":"Addabbo, T., Bertocci, F., Fort, A., Gregorkiewitz, M., Mugnaini, M., Spinicci, R., Vignoli, V.: Gas sensing properties and modeling of YCoO3 based perovskite materials. Sens. Actuators B Chem. 221, 1137\u20131155 (2015). \n                    https:\/\/doi.org\/10.1016\/j.snb.2015.07.079","journal-title":"Sens. Actuators B Chem."},{"issue":"6","key":"9_CR4","doi-asserted-by":"publisher","first-page":"1352","DOI":"10.3390\/s17061352","volume":"17","author":"Francesco Bertocci","year":"2017","unstructured":"Bertocci, F., Fort, A., Vignoli, V., Mugnaini, M., Berni, R.: Optimization of perovskite gas sensor performance: characterization, measurement and experimental design. Sensors (Switzerland), 17 (6), art. no. 1352 (2017). \n                    https:\/\/doi.org\/10.3390\/s17061352","journal-title":"Sensors"},{"key":"9_CR5","doi-asserted-by":"publisher","unstructured":"Fort, A., Rocchi, S., Serrano-Santos, M.B., Spinicci, R., Ulivieri, N., Vignoli, V.: Electronic noses based on metal oxide gas sensors: The problem of selectivity enhancement. In: 21st IEEE Instrumentation and Measurement Technology Conference, vol. 1, pp. 599\u2013604. IEEE Press (2004). \n                    https:\/\/doi.org\/10.1109\/imtc.2004.1351121","DOI":"10.1109\/imtc.2004.1351121"},{"key":"9_CR6","doi-asserted-by":"publisher","first-page":"1054","DOI":"10.1016\/j.snb.2017.01.054","volume":"244","author":"T Addabbo","year":"2017","unstructured":"Addabbo, T., Bertocci, F., Fort, A., Gregorkiewitz, M., Mugnaini, M., Spinicci, R., Vignoli, V.: Gas sensing properties of YMnO3 based materials for the detection of NOx and CO. Sens. Actuators B Chem. 244, 1054\u20131070 (2017). \n                    https:\/\/doi.org\/10.1016\/j.snb.2017.01.054","journal-title":"Sens. Actuators B Chem."},{"issue":"1","key":"9_CR7","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.snb.2011.06.052","volume":"159","author":"A Fort","year":"2011","unstructured":"Fort, A., Mugnaini, M., Pasquini, I., Rocchi, S., Vignoli, V.: Modeling of the influence of H2O on metal oxide sensor responses to CO. Sens. Actuators B Chem. 159(1), 82\u201391 (2011). \n                    https:\/\/doi.org\/10.1016\/j.snb.2011.06.052","journal-title":"Sens. Actuators B Chem."}],"container-title":["Lecture Notes in Electrical Engineering","Sensors"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/978-3-030-04324-7_9","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,5,17]],"date-time":"2019-05-17T23:01:44Z","timestamp":1558134104000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/978-3-030-04324-7_9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019]]},"ISBN":["9783030043230","9783030043247"],"references-count":7,"URL":"https:\/\/doi.org\/10.1007\/978-3-030-04324-7_9","relation":{},"ISSN":["1876-1100","1876-1119"],"issn-type":[{"type":"print","value":"1876-1100"},{"type":"electronic","value":"1876-1119"}],"subject":[],"published":{"date-parts":[[2019]]},"assertion":[{"value":"18 January 2019","order":1,"name":"first_online","label":"First Online","group":{"name":"ChapterHistory","label":"Chapter History"}},{"value":"CNS","order":1,"name":"conference_acronym","label":"Conference Acronym","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Convegno Nazionale Sensori","order":2,"name":"conference_name","label":"Conference Name","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Catania","order":3,"name":"conference_city","label":"Conference City","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"Italy","order":4,"name":"conference_country","label":"Conference Country","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"2018","order":5,"name":"conference_year","label":"Conference Year","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"21 February 2018","order":7,"name":"conference_start_date","label":"Conference Start Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"23 February 2018","order":8,"name":"conference_end_date","label":"Conference End Date","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"4","order":9,"name":"conference_number","label":"Conference Number","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"cns2018","order":10,"name":"conference_id","label":"Conference ID","group":{"name":"ConferenceInfo","label":"Conference Information"}},{"value":"http:\/\/www.cns2018.it\/","order":11,"name":"conference_url","label":"Conference URL","group":{"name":"ConferenceInfo","label":"Conference Information"}}]}}